scholarly journals Aspheric Intraocular Lenses Implantation for Cataract Patients with Extreme Myopia

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Yanwen Fang ◽  
Yi Lu ◽  
Aizhu Miao ◽  
Yi Luo

Objective. To evaluate the postoperative visual quality of cataract patients with extreme myopia after implantation of aspheric intraocular lenses (IOLs). Methods. Thirty-three eyes were enrolled in this prospectivestudy. Eighteen eyes with an axial length longer than 28 mm were included in the extreme myopia group, and the other 15 eyes were included in the nonextreme myopia group. Phacoemulsification and aspheric IOL implantation were performed. Six months after cataract surgery, best-corrected visual acuity (BCVA), contrast sensitivity, and wavefront aberrations were measured, and subjective visual quality was assessed. Results. The BCVA improved significantly after surgery for both groups, and patients in the nonextreme myopia group achieved better postoperative BCVA due to better retinal status of the eyes. The evaluation of contrast sensitivity without glare was the same in both groups, whereas patients in the nonextreme myopia group performed better at intermediate spatial frequencies under glare conditions. The two groups did not show a significant difference in high-order aberrations. With regard to subjective visual quality, the composite scores of both groups did not differ significantly. Conclusions. Aspheric IOLs provided good visual outcomes in cataract patients with extreme myopia. These patients should undergo careful evaluation to determine the maculopathy severity level before surgery.

2011 ◽  
Vol 21 (6) ◽  
pp. 732-740
Author(s):  
Yanwen Fang ◽  
Yi Lu ◽  
Xinhua Wu ◽  
Aizhu Miao ◽  
Yi Luo

Purpose. To evaluate and compare the objective and subjective visual function after implantation of 2 aspheric intraocular lenses (IOLs) in Chinese cataract patients. Methods. Forty-one eyes of 28 patients with cataract were randomly assigned to receive either the MC X11 ASP IOL or the AcrySof IQ IOL. Three months postoperatively, best-corrected visual acuity (BCVA), contrast sensitivity, wavefront aberrations, and subjective visual quality were measured. The degree of posterior capsule opacification (PCO) was recorded at last follow-up. Results. Postoperative mean monocular BCVA was 0.05±0.13 logMAR in the MC X11 group and 0.05±0.08 logMAR in the IQ group. There was no significant difference in visual acuity, contrast sensitivity, subjective visual quality, and degree of PCO between the 2 groups. For a 6-mm pupil diameter, the mean spherical aberration (Z40) was 0.075±0.076 μm in the MC X11 group and 0.056±0.111 μm in the IQ group. However, 45.5% and 57.9% of the eyes in the MC X11 and IQ groups had values >0.10 μm, respectively. The mean RMS values of the high-order aberrations were similar between the 2 groups except the higher fifth- and sixth-order aberrations, which were significantly higher in the MC X11 group. Conclusions. Both IOLs provided similar and good visual outcomes. However, the data suggest that the amount of negative spherical aberration generated by current available aspheric IOLs might not be optimal for Chinese eyes.


2021 ◽  
Vol 14 (3) ◽  
pp. 356-365
Author(s):  
Farideh Doroodgar ◽  
◽  
Azad Sanginabadi ◽  
Farid Karimian ◽  
Sana Niazi ◽  
...  

AIM: To compare the clinical outcomes of a variety of multifocal intraocular lenses (MIOLs) in patients diagnosed with presbyopia or cataracts. METHODS: This clinical trial study included 141 patients (282 eyes) with different MIOLs implantation. The Symfony (60 eyes), the ReSTOR (100 eyes), the AT LISAtri (60 eyes), and the PanOptix (62 eyes) intraocular lenses were evaluated in this prospective interventional study. The near, intermediate, and distant visual acuities, contrast sensitivity, and defocus curve were measured as valid criteria. To statistically analyze the results, we used the Statistical Package for Social Science software, the non-parametric Wilcoxon signed-rank t, the one-way analysis of variance and the Tukey's post-hoc test in our analysis. Moreover, we conducted a detailed literature search on the PubMed database in English about MIOLs, in total 59 studies were included in this review article. RESULTS: The four approaches did not show any significant difference in the best-corrected distance visual acuity (P>0.05). The defocus curves at the contrast of 100% showed that trifocal IOLs had better intermediate performance than the bifocal IOL (P<0.05). There were no statistically significant differences between AT LISAtri and PanOptix lenses for visual acuity at all distances. The eyes with PanOptix, Symfony, and AT LISAtri IOL showed better contrast sensitivity than those ReSTOR at spatial frequencies of 1, 3, and 6 cpd in photopic and mesopic conditions (P<0.001). CONCLUSION: All four groups of the multifocal lenses were satisfying in terms of distance and near vision. Also, the group of trifocal lenses led to satisfactory outcomes in intermediate vision, without degradation in quality of vision.


2021 ◽  
pp. 112067212110676
Author(s):  
Cem Ozturkmen ◽  
Cem Kesim ◽  
Pinar Gunel Karadeniz ◽  
Afsun Sahin

Purpose To compare visual acuity, defocus curve and visual quality of life performances of a new hybrid refractive-diffractive intraocular lens (IOL) and a trifocal diffractive IOL. Methods Patients who underwent cataract surgery with bilateral implantation of ZFR00V or TFNT00 IOLs were enrolled in this study. The main outcomes were defined as uncorrected distant, intermediate and near visual acuities (UDVA, UIVA and UNVA, respectively), defocus curve and VF-14 questionnaire aimed for visual performance. Results Fifty patients, of whom 30 had bilateral ZFR00V implantation, were enrolled in the study. Patients with ZFR00V had significantly better UIVA than patients with TFNT00 (0.05 ± 0.03 vs. 0.07 ± 0.04 logMAR, P = 0.02). Defocus curve showed significantly higher visual acuity in intermediate range for ZFR00V IOL between −1.00 and −1.50 dioptres (all P < 0.05). All patients had good visual performance with mean VF-14 scores above 3 points with no significant difference between two IOL models. Spectacle independence was 100% for both distant and near vision in both group of patients. Conclusion Bilateral implantation of ZFR00V in cataract patients shows better intermediate visual acuity scores and similar daily visual performance when compared with trifocal TFNT00 IOL.


2020 ◽  
Vol 1 (4) ◽  
pp. 259-283
Author(s):  
Chin Chiet Ying Alice ◽  
Banumathi Gurusamy ◽  
Lim Keat Andrew ◽  
Mae-Lynn Catherine Bastion

Introduction: Evolution of cataract surgery and implantation of intraocular lenses (IOL) with new technological designs to optimise functional vision has been the aim of cataract surgery today. Aspherical lens design is a new lens technology to counteract spherical aberration exerted by a conventional IOL. Purpose: To compare the contrast sensitivity after cataract surgery between aspheric IOLs with negative spherical aberration (Tecnis ZA9003TM and AcrySof IQTM) and zero spherical aberration IOLs (Akreos Adapt Advance Optic [AO]TM). Study design: Interventional, single-blinded, randomised controlled trial. Methods: Ninety-six patients were recruited with 32 eyes in each study arm. All patients underwent standard phacoemulsification with implantation of an aspheric acrylic IOL randomised to one of the three lens models by a single experienced surgeon. Pre- and postoperative contrast sensitivity was analysed using the CSV1000E chart under photopic and mesopic conditions with and without glare testing. Results: All three lenses showed statistically significant improvement in contrast sensitivity postoperatively at all spatial frequencies under photopic, mesopic, and scotopic conditions with glare. There was no statistically significant difference between the groups. Tecnis ZA9003TM showed marked improvement in mesopic contrast sensitivity at 18 cycles/degree (cpd) at 12 weeks (p < 0.05). The zero aberration Akreos Adapt AOTM showed better photopic contrast sensitivity compared to mesopic contrast sensitivity (p > 0.05). Conclusion: AcrySof IQTM, Akreos Adapt AOTM, and Tecnis ZA9003TM performed equally well in contrast sensitivity at all spatial frequencies under photopic and mesopic conditions with and without glare testing. All lenses had statistically significant improvement in contrast sensitivity after cataract surgery. The negative aberration IOL Tecnis ZA9003TM showed marked improvement in mesopic contrast sensitivity at 18 cpd at 12 weeks. The zero aberration IOL, Akreos Adapt AOTM showed better photopic contrast sensitivity compared to mesopic contrast sensitivity.


2021 ◽  
pp. 112067212110697
Author(s):  
Elizabeth M. Law ◽  
Rajesh K. Aggarwal ◽  
Hetal Buckhurst ◽  
Hosam E. Kasaby ◽  
Jonathan Marsden ◽  
...  

Purpose To evaluate visual performance with trifocal and extended depth of focus IOL at 1 year post-operatively. Setting BMI Southend Hospital. Design Cohort study. Methods An age-matched cohort of forty subjects bilaterally implanted with the AT LISA 839MP trifocal IOL (20 patients, 40 eyes) and the Tecnis Symfony extended depth of focus IOL (20 patients, 40 eyes) were assessed at 3–6 months and 12–18 months post-operatively. Primary outcome measures were distance (6 m), intermediate (70 cm), near visual acuity (40 cm), and analysis of defocus profiles. Secondary outcomes included contrast sensitivity, Radner reading performance, quality of vision and assessment of halos. Results Distance visual acuity (VA) and defocus areas were similar ( p = 0.07). No significant difference in intermediate VA was noted but the intermediate area of focus was greater in the EDoF (0.31 ± 0.12 LogMAR*m−1) compared to the trifocal (0.22 ± 0.08LogMAR*m−1) ( p = 0.02). However, all near metrics were significantly better in the trifocal group. 80% of trifocal subjects were spectacle independent compared to 50% EDoF subjects. Quality of vision questionnaire found no significant differences between groups, however halo scores were greater at 3–6 months in the trifocal group ( p < 0.01) but no differences were noted at 12–18 months. Conclusions Near vision is significantly better for the trifocal, thus greater levels of spectacle independence. The range of intermediate vision was greater for the EDoF but no difference in intermediate VA. In the early period, differences in contrast sensitivity and halo size/intensity were noted, however, by one-year these measures were not significantly different.


Author(s):  
Argyrios Tzamalis ◽  
Myron Kynigopoulos ◽  
Grigoris Pallas ◽  
Ioannis Tsinopoulos ◽  
Nikolaos Ziakas

Purpose: To evaluate the effect of asphericity and blue light filter (BLF) of three different intraocular lenses (IOLs) on the visual performance, second- and third-order aberrations (defocus, coma, trefoil), and contrast sensitivity after uneventful cataract surgery. Methods: One hundred and twenty eyes of 60 patients with clinically significant cataract were randomly assigned to receive one of the three IOL types: Bioline Yellow Accurate (aspheric, with BLF, i-medical, Germany), BioAcryl 60125 (spherical, without BLF, Biotech, France), and H65C/N (aspheric, without BLF, PhysIOL, Belgium). Each IOL was implanted in 40 eyes. Complete ophthalmologic examination, functional acuity contrast testing and wavefront analysis were performed 60 days postoperatively. Results: The mean postoperative best-corrected visual acuity (BCVA) was 0.95 ± 0.08, not differing statistically among the IOL groups (P = 0.83). Mean defocus and coma values did not yield any statistically significant difference through the IOL groups varying from –0.784 to –0.614 μm and 0.129 to 0.198 μm (P = 0.79 and 0.34, respectively). Bioline Yellow Accurate IOL presented less trefoil aberrations, 0.108 ± 0.05 μm, compared to the other two IOL types (BioAcryl [0.206 ± 0.19 μm] and Physiol [0.193 ± 0.17 μm], P < 0.05). Contrast sensitivity values did not differ among the groups under all lighting conditions. Bioline Yellow IOL showed a statistically higher loss of contrast sensitivity (between mesopic and mesopic with glare conditions) compared to the BioAcryl and PhysIOL in 12 and 3 cpd spatial frequencies, respectively (P < 0.05). Conclusion: Bioline Yellow IOL indicated lower contrast sensitivity under mesopic conditions when glare was applied but resulted in less trefoil aberrations after uneventful cataract surgery. No further differences were noted in postoperative visual performance among three IOL groups.


2020 ◽  
Vol 36 (7) ◽  
Author(s):  
Huifang Lian ◽  
Weisong Ma ◽  
Qiuhong Wei ◽  
Xiaoyong Yuan

Objectives: To compare early subjective and objective vision quality of postoperative patients undergoing phacoemulsification cataract surgery combined with implantation of refractive segmental multifocal intraocular lens (MIOL) SBL-3 and apodized diffractive MIOL SN6AD1. Methods: As a prospective study, it enrolled 53 patients (53 eyes) to undergo phacoemulsification cataract surgery combined with MIOL implantation. According to differences in MIOL implanted, patients were divided into a SBL-3 group (25 eyes) and a SN6AD1 group (28 eyes). Ophthalmological evaluation included uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate (UIVA) and near (UNVA) visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA)visual acuities and corrected near(CNVA) visual acuity, contrast sensitivity, modulation transfer function (MTF) and high order aberration (4 mm pupil diameter) at three months postoperatively. Moreover, a questionnaire survey was carried out to assess near spectacle independence, patient satisfaction and symptoms of visual disturbance. Results: At three months after surgery, UIVA and UNVA in the SBL-3 group are statistically significantly superior to those of the SN6AD1 group (P<0.05). There was statistical difference in contrast sensitivity at four spatial frequencies (3, 6, 12, 18cycles/degree) under mesopic conditions and mesopic conditions with glare (P<0.05). The total ocular high order aberration, coma and trefoil were statistically significantly larger in the SBL-3 group than in the SN6AD1 group with 4.0 mm pupil diameters (P<0.05). Statistical differences were found in the MTF at spatial frequencies of 5, 10 and 15 cycles/degree between the groups. There were no significant differences in spectacle independence, patient satisfaction and visual disturbance between the groups (P>0.05). Conclusions: Both the two multifocal intraocular lens provided an excellent level of quality of vision three months postoperatively. However, the application effect of SBL-3 MIOL is superior to that of SN6AD1 MIOL as far as intermediate vision, near vision and contrast sensitivity are concerned. doi: https://doi.org/10.12669/pjms.36.7.3364 How to cite this:Lian H, Ma W, Wei Q, Yuan X. A comparative study on early vision quality after implantation of refractive segmental and diffractive multifocal intraocular lens. Pak J Med Sci. 2020;36(7):---------. doi: https://doi.org/10.12669/pjms.36.7.3364 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Zhonghao Ren ◽  
Liyan Xu ◽  
Qi Fan ◽  
Kaili Yang ◽  
Shengwei Ren ◽  
...  

Purpose. The study aimed to evaluate the visual quality of forme fruste keratoconus (FFK) and mild and moderate keratoconus by using an optical quality analysis system II (OQAS-II) and to explore the correlation between optical quality parameters and the disease progression. Methods. Twenty-one normal eyes, twenty-one FFK eyes, twenty-one mild keratoconus eyes, and twenty-one moderate keratoconus eyes were included in this prospective study. The optical quality parameters, such as object scatter index (OSI), modulation transfer function cutoff (MTF cutoff), strehl ratio (SR), and OQAS-II values at contrasts of 100% (OV-100), 20% (OV-20), and 9% (OV-9), were measured by OQAS-II. The repeatability of these parameters was analyzed by intraclass correlation coefficient (ICC), repeatability coefficient (RC), and coefficient of variation (CVw). Correlations between optical quality parameters and mean central keratometry readings (Kmean) were evaluated. The sensitivity and specificity of the parameters were analyzed using the receiver operating characteristic (ROC). Results. All the optical quality parameters among four groups showed good repeatability (all ICC≥0.75). The MTF cutoff, SR, OV-100, OV-20, OV-9 in FFK, mild and moderate keratoconus eyes were significantly lower than those in the normal group (all P<0.05). The ROC analyses of the MTF cutoff, SR, OV-100, OV-20, and OV-9 showed significant area under the curve (AUC) in discriminating FFK form normal, mild keratoconus from FFK, and moderate keratoconus from mild keratoconus (all P<0.05). The OSI in mild and moderate keratoconus eyes were significantly higher than that in FFK and normal group (all P<0.05), while the OSI showed no significant difference between the FFK group and normal group (P>0.05). The ROC analyses of the OSI showed significant AUC in discriminating mild keratoconus from FFK and moderate keratoconus from mild keratoconus (all P<0.05). In addition, the MTF cutoff was closely correlated to Kmean in keratoconus eyes (r = −0.710, P<0.001). Conclusion. The repeatability of OQAS-II is good in measuring visual quality of normal as well as FFK, mild, and moderate keratoconus. The visual quality of the FFK, mild, and moderate keratoconus is worse than that in normal eyes. The OQAS-II has the potential value in screening FFK from normal eyes and might be a useful tool for evaluating the progression of keratoconus.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Sylwia Wagner ◽  
Grzegorz Wagner ◽  
Ewa Mrukwa-Kominek

Purpose. Long-term evaluation of the visual refractive outcomes and the quality of life after implantation of the WIOL-CF (Medicem, Czech Republic) in both eyes. Design. retrospective, nonrandomized noncomparative case series. Methods. 50 eyes of 25 patients, including 11 women (44%) and 14 men (56%). The age range of the patients was 38 to 77 years (mean age 55.48 ± 10.97 years). All patients underwent bilateral implantation of the WIOL-CF. Exclusion criteria were previous ocular surgeries except for cataract surgery and refractive lens exchange, irregular corneal astigmatism of >1.0 diopter, and ocular pathologies or corneal abnormalities. Postoperative examinations were performed at 14 days and 3, 6, 12 months of surgery; the last follow-up was between 24 and 36 months after the procedure. All exams included manifest refraction, monocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 5 m (Snellen), monocular uncorrected visual acuity in 70 cm and 40 cm (Jeager) and binocular UCVA, DCVA in 5 m, 70 cm, and 40 cm, binocular contrast sensitivity (CS) under photopic conditions, binocular defocus curves, high-order aberrations, quality-of-vision VF-14 questionnaire, and spectacle independence. Results. Significant improvement in monocular visual acuity at all distances was demonstrated; the mean postoperative spherical equivalent was 0.32 ± 0.45D. The postoperative means of binocular distance UCVA and BCVA were also improved ( p  < .001) and so were the mean uncorrected intermediate VA (2.053 ± 1.268) and near uncorrected VA (2.737 ± 1.447). There was a significant improvement in contrast sensitivity at all spatial frequencies and higher-order aberration, compared to preoperative results. Conclusions. The evaluation of a WIOL-CF showed good distance, intermediate, and near visual acuity. Contrast sensitivity increased after surgery in all spatial frequencies. Patient satisfaction was high despite some optical phenomena. The rate of postoperative spectacle independence also turned out high. Financial Disclosure. No author has a financial or proprietary interest in any material or method mentioned.