scholarly journals Development and Validation of Simple RP-HPLC Method for Intracellular Determination of Fluconazole Concentration and Its Application to the Study ofCandida albicansAzole Resistance

2015 ◽  
Vol 2015 ◽  
pp. 1-8 ◽  
Author(s):  
Tigran K. Davtyan ◽  
Levon A. Melikyan ◽  
Nune A. Nikoyan ◽  
Hripsime P. Aleksanyan ◽  
Nairi G. Grigoryan

Candida albicans(strains NCTC-885-653 and ATCC-10231) long-term cultivated in the presence of antifungal agent fluconazole (FLC) and classical microbiological methods for determination of minimal inhibitory concentration (MIC) were used in this study. A simple and sensitive method based on reverse-phase high-performance liquid chromatography (RP-HPLC) has been developed for the determination of FLC intracellular concentration inC. albicansusing tinidazole as an internal standard. Following extraction with dichloromethane, the chromatographic separation was achieved on a Machery-Nagel EC250/2 Nucleodur-100-3 C18 column by gradient elution using the mobile phase consisting of (A) 0.01 M ammonium acetate buffer, pH = 5.00, and (B) acetonitrile. Different analytical performance parameters such as linearity, precision, accuracy, limit of quantification (LOQ), and robustness were determined according to US DHHS FDA and EMEA guidelines. The method was linear for FLC(r=0.9999)ranging from 100 to 10000 ng/mL. The intraday and interday precisions (relative standard deviation) were within 2.79 and 2.64%, respectively, and the accuracy (relative error) was less than 2.82%. The extraction recovery ranged from 79.3 to 85.5%. The reliable method was successfully applied toC. albicansazole-resistance study and it was shown that intracellular concentration of FLC correlated with a yeast drug susceptibility profile and MIC values.

2012 ◽  
Vol 57 (1) ◽  
pp. 484-489 ◽  
Author(s):  
Mei Zhang ◽  
Grant A. Moore ◽  
Murray L. Barclay ◽  
Evan J. Begg

ABSTRACTA rapid and simple high-performance liquid chromatography (HPLC) assay was developed for the simultaneous determination of three triazole antifungals (voriconazole, posaconazole, and itraconazole and the metabolite of itraconazole, hydroxyitraconazole) in human plasma. Sample preparation involved a simple one-step protein precipitation with 1.0 M perchloric acid and methanol. After centrifugation, the supernatant was injected directly into the HPLC system. Voriconazole, posaconazole, itraconazole, its metabolite hydroxyitraconazole, and the internal standard naproxen were resolved on a C6-phenyl column using gradient elution of 0.01 M phosphate buffer, pH 3.5, and acetonitrile and detected with UV detection at 262 nm. Standard curves were linear over the concentration range of 0.05 to 10 mg/liter (r2> 0.99). Bias was <8.0% from 0.05 to 10 mg/liter, intra- and interday coefficients of variation (imprecision) were <10%, and the limit of quantification was 0.05 mg/liter.


2015 ◽  
Vol 13 (2) ◽  
pp. 125-131
Author(s):  
Anisa Alam Tanam ◽  
Mohammad Firoz Khan ◽  
Ridwan Bin Rashid ◽  
Md Zakir Sultan ◽  
Mohammad A Rashid

Acetaminophen (paracetamol) is an analgesic and antipyretic agent with minimum anti-inflammatory properties. In the present study a simple, fast, accurate, precise and reproducible RP-HPLC method has been developed and validated for the quantification of paracetamol in human serum samples using theophylline as internal standard. Protein precipitation with perchloric acid was employed in the extraction of paracetamol and theophylline from biological matrix. The chromatographic separation was accomplished on Phenomenex C18 column with a mobile phase comprising of 0.05 mM sodium sulfate buffer (pH 2.2 ± 0.02 adjusted with phosphoric acid) and acetonitrile at a ratio of 93:7 at a flow rate of 1.0 ml/min. The chromatogram was monitored by UV detection at a wavelength of 254 nm. The method was validated over a linear concentration range of 2-100 ?g/ml and limit of quantification (LOQ) was 1.61 ?g/ml with a correlation coefficient (r2) 0.997. The intra-day and inter-day precision expressed as relative standard deviation were found to be 0.49 - 2.68% and 0.36 - 3.44%, respectively. The average recovery of paracetamol from serum ranged from 99.0 - 106.4%. The method was successfully applied to a pharmacokinetic study after oral administration of immediate release paracetamol tablet (1000 mg) in four healthy Bangladeshi volunteers. The mean Cmax was found to be 11.03 ± 3.21 ?g/ml, which occurred at Tmax of 0.88 ± 0.14 hr. The half life, AUC0-8 and AUC0-? values were found to be 3.09 ± 0.71 hr, 31.06 ± 6.57 hr-?g/ml and 37.92 ± 9.51 hr- ?g/ml, respectively. DOI: http://dx.doi.org/10.3329/dujps.v13i2.21889 Dhaka Univ. J. Pharm. Sci. 13(2): 125-131, 2014 (December)


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Qiang Wang ◽  
Xu-Feng Wang ◽  
Yong-Yuan Jiang ◽  
Zhi-Guang Li ◽  
Nan Cai ◽  
...  

AbstractWe developed a significantly improved ultra-high performance liquid chromatography-tandem mass spectrometry method for determination of 5-nitro-2-furaldehyde (NF) as a surrogate using a novel internal standard for the detection of nitrofurazone. We used 2,4-dinitrophenylhydrazine derivatization and furfural as the internal standard. Derivatization was easily performed in HCl using ultrasonic manipulation for 5 min followed by liquid extraction using ethyl acetate. The samples were concentrated and purified using reverse phase and alumina cartridges in tandem. The derivatives were separated using a linear gradient elution on a C18 column with methanol and water as the mobile phase in negative ionization mode and multiple reaction monitoring. Under the optimized conditions, the calibration curves were linear from 0.2 to 20 μg/L with correlation coefficients >0.999. Mean recoveries were 80.8 to 104.4% with the intra- and inter-day relative standard deviations <15% at spiking levels of 0.1 to 10 μg/kg. The limits of detection and quantification were 0.05 and 0.1 μg/kg, respectively. This method is a robust tool for the identification and quantitative determination of NF in shrimp samples.


2020 ◽  
Vol 16 (8) ◽  
pp. 1106-1112
Author(s):  
Ibrahim A. Darwish ◽  
Nasr Y. Khalil ◽  
Mohammad AlZeer

Background: Axitinib (AXT) is a member of the new generation of the kinase inhibitor indicated for the treatment of advanced renal cell carcinoma. Its therapeutic benefits depend on assuring the good-quality of its dosage forms in terms of content and stability of the pharmaceutically active ingredient. Objective: This study was devoted to the development of a simple, sensitive and accurate stabilityindicating high-performance liquid chromatographic method with ultraviolet detection (HPLC-UV) for the determination of AXT in its bulk and dosage forms. Methods: Waters HPLC system was used. The chromatographic separation of AXT, internal standard (olaparib), and degradation products were performed on the Nucleosil CN column (250 × 4.6 mm, 5 μm). The mobile phase consisted of water:acetonitrile:methanol (40:40:20, v/v/v) with a flow rate of 1 ml/min, and the UV detector was set at 225 nm. AXT was subjected to different accelerated stress conditions and the degradation products, when any, were completely resolved from the intact AXT. Results: The method was linear (r = 0.9998) in the concentration range of 5-50 μg/ml. The limits of detection and quantitation were 0.85 and 2.57 μg/ml, respectively. The accuracy of the method, measured as recovery, was in the range of 98.0-103.6% with relative standard deviations in the range of 0.06-3.43%. The results of stability testing revealed that AXT was mostly stable in neutral and oxidative conditions; however, it was unstable in alkaline and acidic conditions. The kinetics of degradation were studied, and the kinetic rate constants were determined. The proposed method was successfully applied for the determination of AXT in bulk drug and dosage forms. Conclusions: A stability-indicating HPLC-UV method was developed and validated for assessing AXT stability in its bulk and dosage forms. The method met the regulatory requirements of the International Conference on Harmonization (ICH) and the Food and Drug Administration (FDA). The results demonstrated that the method would have great value when applied in quality control and stability studies for AXT.


2020 ◽  
Vol 16 (4) ◽  
pp. 428-435
Author(s):  
Ahmed F.A. Youssef ◽  
Yousry M. Issa ◽  
Kareem M. Nabil

Background: Simeprevir is one of the recently discovered drugs for treating hepatitis C which is one of the major diseases across the globe. Objective: The present study involves the development of a new and unique High-Performance Liquid Chromatography (HPLC) method using fluorescence detection for the determination of simeprevir (SIM) in human plasma. Methods: Two methods of extractions were tested, protein precipitation using acetonitrile and liquidliquid extraction. A 25 mM dipotassium hydrogen orthophosphate (pH 7.0)/ACN (50/50; v/v), was used as mobile phase and C18 reversed phase column as the stationary phase. The chromatographic conditions were optimized and the concentration of simeprevir was determined by using the fluorescence detector. Cyclobenzaprine was used as an internal standard. Results: Recovery of the assay method based on protein precipitation was up to 100%. Intra-day and inter-day accuracies range from 92.30 to 107.80%, with Relative Standard Deviation (RSD) range 1.65-8.02%. The present method was successfully applied to a pharmacokinetic study where SIM was administered as a single dose of 150 mg SIM/capsule (Olysio®) to healthy individuals. Conclusion: This method exhibits high sensitivity with a low limit of quantification 10 ng mL-1, good selectivity using fluorescence detection, wide linear application range 10-3000 ng mL-1, good recovery and highly precise and validation results. The developed method can be applied in routine analysis for real samples.


2012 ◽  
Vol 11 (1) ◽  
pp. 55-63 ◽  
Author(s):  
Maizbha Uddin Ahmed ◽  
Mohammad Safiqul Islam ◽  
Tasmin Ara Sultana ◽  
AGM Mostofa ◽  
Muhammad Shahdaat Bin Sayeed ◽  
...  

Azithromycin is an effective and well-known antimicrobial agent. In the present study, a simple, sensitive and specific LC/MS/MS method has been developed and validated for the quantification of Azithromycin in  human serum samples using Clarithromycin as internal standard. Azithromycin was extracted from biological matrix  by using solid phase extraction process. The chromatographic separation was performed on Luna C18 (3 ?, 2x150   mm) column with a mobile phase consisting of 35 mM ammonium acetate buffer (mobile phase-A) and acetonitrile  and methanol in ratio of 90:10 ( as mobile phase-B) at a flow rate of 0.25 mL/min. The method was validated over a  linear concentration range of 0.5?50.0 ng/mL and limit of quantification (LOQ) was 0.5 ng/mL with a coefficient of  correlation (r2) = 0.9998. The intra-day and inter-day precision expressed as relative standard deviation were 1.64% – 8.43% and 2.32% – 9.92%, respectively. The average recovery of azithromycin from serum was 98.11%. The method  was successfully applied to a pharmacokinetic study after oral administration of Azithromycin 200 mg/5 ml suspension in healthy Bangladeshi volunteers. DOI: http://dx.doi.org/10.3329/dujps.v11i1.12488 Dhaka Univ. J. Pharm. Sci. 11(1): 55-63, 2012 (June)


2017 ◽  
Vol 20 (2) ◽  
pp. 241-249 ◽  
Author(s):  
A. Jasiecka-Mikołajczyk ◽  
J.J. Jaroszewski

Abstract Tigecycline (TIG), a novel glycylcycline antibiotic, plays an important role in the management of complicated skin and intra-abdominal infections. The available data lack any description of a method for determination of TIG in avian plasma. In our study, a selective, accurate and reversed-phase high performance liquid chromatography-tandem mass spectrometry method was developed for the determination of TIG in turkey plasma. Sample preparation was based on protein precipitation and liquid-liquid extraction using 1,2-dichloroethane. Chromatographic separation of TIG and minocycline (internal standard, IS) was achieved on an Atlantis T3 column (150 mm × 3.0 mm, 3.0 μm) using gradient elution. The selected reaction monitoring transitions were performed at 293.60 m/z → 257.10 m/z for TIG and 458.00 m/z → 441.20 m/z for IS. The developed method was validated in terms of specificity, selectivity, linearity, lowest limit of quantification, limit of detection, precision, accuracy, matrix effect, carry-over effect, extraction recovery and stability. All parameters of the method submitted to validation met the acceptance criteria. The assay was linear over the concentration range of 0.01-100 μg/ml. This validated method was successfully applied to a TIG pharmacokinetic study in turkey after intravenous and oral administration at a dose of 10 mg/kg at various time-points.


Author(s):  
Muhammad Fawad Rasool ◽  
Umbreen Fatima Qureshi ◽  
Nazar Muhammad Ranjha ◽  
Imran Imran ◽  
Mouqadus Un Nisa ◽  
...  

AbstractTh accurate rapid, simple and selective reversed phase high performance liquid chromatography (RP-HPLC) has been established and validated for the determination of captopril (CAP). Chromatographic separation was accomplished using prepacked ODSI C18 column (250 mm × 4.6 mm with 5 μm particle size) in isocratic mode, with mobile phase consisting of water: acetonitrile (60:40 v/v), pH adjusted to 2.5 by using 85% orthophosphoric acid at a flow rate of 1 mL/min and UV detection was performed at 203 nm. RP-HPLC method used for the analysis of CAP in mobile phase and rabbit plasma was established and validated as per ICH-guidelines. It was carried out on a well-defined chromatographic peak of CAP was established with a retention time of 4.9 min and tailing factor of 1.871. The liquid–liquid extraction method was used for extraction of CAP from the plasma. Excellent linearity (R2 = 0.999) was shown over range 3.125–100 µg/mL with mean percentage recoveries ranges from 97 to 100.6%. Parameters of precision and accuracy of the developed method meet the established criteria. Intra and inter-day precision (% relative standard deviation) study was also performed which was less than 2% which indicate good reproducibility of the method. The limit of detection (LOD) and quantification for the CAP in plasma were 3.10 and 9.13 ng/mL respectively. The method was suitably validated and successfully applied to the determination of CAP in rabbit plasma samples.


Author(s):  
Kumar S. Ashutosh ◽  
Debnath Manidipa ◽  
Rao J.V.L.N. Seshagiri ◽  
Sankar D. Gowri

This paper is concern with a reverse phase high performance liquid chromatography (RP-HPLC) bio-analytical method development and validation for Prasugrel in human plasma using photo diode array detector (PDA detector). The HPLC separation was carried out in an isocratic mode on an X-Terra C18 column (4.6 x 150 mm; 5 μm) with a mobile phase consisting of potassium dihydrogen phosphate [pH 3.0] and acetonitrile in the ratio of 30:70 v/v at a flow rate of 1.0 mL/min. The run time was maintained for 5 mins and the detection was monitored at 210 nm. The percentage recovery was found 99.61-100.06 in human plasma. This reveals that the method is quite accurate. The linearity was found 15-40 μg/mL in human plasma. The inter-day and intra-day precision in plasma was found within the limits. The lower limit of quantification (LLOQ) obtained by the proposed method was 0.05 μg/mL. The percentage relative standard deviation (%RSD) obtained for the drug spiked in plasma for stability studies were less than 2 %.Kathmandu University Journal of Science, Engineering and TechnologyVol. 13, No. 1, 2017, Page: 65-75


2021 ◽  
Author(s):  
Tao Lin ◽  
Xinglian Chen ◽  
Li Wang ◽  
Haixian Fang ◽  
Maoxuan Li ◽  
...  

Abstract The simultaneous determination method of 8 amide pesticides by multi-walled carbon nanotubes (MWCNs) cleanup, combined with QuEChERS method and ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry has been developed and successfully applied in complex matrix such as green onions, celery, leeks, citrus, lychees, avocado. The matric effect of MWCNs is optimized and compared with QuEChERS materials. The results show that MWCNs can effectively reduce the matrix effect in sample extraction. The mass spectrometry is optimized, through their chemical structure skeletons, the ESI+ and ESI- mode are simultaneously scanned in the method. The coefficient (r) is greater than 0.9990, the limit of quantification ranges from 0.03 to 0.80 μg/kg, the recovery rate ranges from 71.2% to 120%, and the relative standard deviation (RSD) ranges from 3.8% to 9.4%. The method is fast, simple, sensitive, and has good purification effect. It is suitable for the rapid determination of amide pesticides in complex matrix agri-food.


Sign in / Sign up

Export Citation Format

Share Document