scholarly journals Rheological Method for Alpha Test Evaluation of Developing Superplasticizers’ Performance: Channel Flow Test

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Jae Hong Kim ◽  
Jin Hyun Lee ◽  
Tae Yong Shin ◽  
Jin Young Yoon

Advance in high-range water-reducing admixture revolutionizes the workability and constructability of conventional vibrated concrete as well as self-consolidating concrete. Its need from construction fields has increased, and consequently a variety of new-type polycarboxylates, base polymers for the admixture, are being formulated in these days. Synthesizing new polymers needs a quick, but reliable, test to evaluate its performance on concrete. The test is also asked for selecting the best applicable brand of them before a test concrete will be mixed. This paper proposes a “channel flow test” and its usage for the purpose. The proposed procedure for the test includes the mix proportion of a test mortar, the test method, and rheological interpretation of the test results.

Author(s):  
Dan Hasnedl ◽  
Premysl Epikaridis

In turbo-machinery, abradable layers are used to protect sensible components while keeping minimal possible clearances for maximum efficiency. This article describes the experimental comparison of state of the art abradable layers used as steam turbine seals and a new type of abradable layer made of a metallic felt. The comparison is done via abradability and leakage testing. The leakage is also compared to a state of the art analytical formula to show the effect on the thermal cycle calculation. An abradable test rig is presented together with the test method. Test results show the value of the Felt seal compared to other two types at low contact speed area. A steam test rig is also presented. Seal leakage at real operating conditions is evaluated and compared to an analytical formula. The leakage results show some efficiency gap compared to other two types of seals.


2010 ◽  
Vol 37 (3) ◽  
pp. 401-412 ◽  
Author(s):  
Md. Safiuddin ◽  
J. S. West ◽  
K. A. Soudki

This paper presents the flowing abilities of various self-consolidating concretes (SCCs) and their binder paste and mortar components. The binder pastes and mortars were formulated from the concrete mixtures and tested for flowing ability with respect to flow time and flow spread, respectively, at various dosages of high-range water reducing admixture (HRWRA). The concrete mixtures were prepared with different water (W) to binder (B) ratios and rice husk ash (RHA) contents. The flowing ability of the concretes was measured with regard to slump flow, orimet flow time and flow spread, and inverted slump cone flow time and flow spread. The test results reveal that the W:B ratio, RHA content, and HRWRA dosage significantly influenced the flowing abilities of the binder pastes, mortars, and concretes. In addition, the flowing ability of the SCCs was well correlated with the flowing abilities of their binder paste and mortar components, except for the mortars including RHA.


2010 ◽  
Vol 168-170 ◽  
pp. 1981-1986
Author(s):  
Wu Jian Long ◽  
Kamal Henri Khayat ◽  
Feng Xing

In general, in the evaluation of a test method, the repeatability tests must be performed to establish upper and lower bounds for the precision of a test method. The repeatability is calculated as a standard deviation and relative error of test results. In order to evaluate the repeatability of the workability tests used in self-consolidating concrete (SCC) applications, an SCC mixture proportioned with 0.38 w/cm, Type MS cement, 480 kg/m3 of binder , and crushed aggregate with MSA of 12.5 mm was used. The dosage rate of the HRWRA of the SCC was adjusted to secure two initial slump flow consistency levels of 630 ± 10 mm and 700 ± 10 mm for the repeatability tests. For each consistency level, the concrete was batched five times (for a total of 10 mixtures). Each test was repeated five times by the same operator in order to establish the single-operator precision values. Furthermore, five different operators were used to perform each of the workability tests in order to assess the multi-operator error that could occur during testing. Based on the relative errors obtained in the repeatability tests, relatively low error values were obtained for the slump flow, J-Ring flow, and L-box blocking ratio tests. Relative errors for recommended SCC workability test methods were also summarized.


2014 ◽  
Vol 496-500 ◽  
pp. 1176-1179
Author(s):  
Li Tan ◽  
Yu Fang

LTX-77 test system is a large IC test system that is used for various kinds of analog IC, digital IC and analog digital mixed IC. It can be used to test DC parameters, AC parameters and logic functions. In the paper, the IC test platform is LTX-77 test system. IC ADC0804 was tested as the test object. The test method of IC is described in the view of actual test. The test results show that the test system is convenient and accurate, which has important practical value for IC manufacturers and users.


BMJ ◽  
2021 ◽  
pp. n1637 ◽  
Author(s):  
Marta García-Fiñana ◽  
David M Hughes ◽  
Christopher P Cheyne ◽  
Girvan Burnside ◽  
Mark Stockbridge ◽  
...  

Abstract Objective To assess the performance of the SARS-CoV-2 antigen rapid lateral flow test (LFT) versus polymerase chain reaction testing in the asymptomatic general population attending testing centres. Design Observational cohort study. Setting Community LFT pilot at covid-19 testing sites in Liverpool, UK. Participants 5869 asymptomatic adults (≥18 years) voluntarily attending one of 48 testing sites during 6-29 November 2020. Interventions Participants were tested using both an Innova LFT and a quantitative reverse-transcriptase polymerase chain reaction (RT-qPCR) test based on supervised self-administered swabbing at testing sites. Main outcome measures Sensitivity, specificity, and predictive values of LFT compared with RT-qPCR in an epidemic steady state of covid-19 among adults with no classic symptoms of the disease. Results Of 5869 test results, 22 (0.4%) LFT results and 343 (5.8%) RT-qPCR results were void (that is, when the control line fails to appear within 30 minutes). Excluding the void results, the LFT versus RT-qPCR showed a sensitivity of 40.0% (95% confidence interval 28.5% to 52.4%; 28/70), specificity of 99.9% (99.8% to 99.99%; 5431/5434), positive predictive value of 90.3% (74.2% to 98.0%; 28/31), and negative predictive value of 99.2% (99.0% to 99.4%; 5431/5473). When the void samples were assumed to be negative, a sensitivity was observed for LFT of 37.8% (26.8% to 49.9%; 28/74), specificity of 99.6% (99.4% to 99.8%; 5431/5452), positive predictive value of 84.8% (68.1% to 94.9%; 28/33), and negative predictive value of 93.4% (92.7% to 94.0%; 5431/5814). The sensitivity in participants with an RT-qPCR cycle threshold (Ct) of <18.3 (approximate viral loads >10 6 RNA copies/mL) was 90.9% (58.7% to 99.8%; 10/11), a Ct of <24.4 (>10 4 RNA copies/mL) was 69.4% (51.9% to 83.7%; 25/36), and a Ct of >24.4 (<10 4 RNA copies/mL) was 9.7% (1.9% to 23.7%; 3/34). LFT is likely to detect at least three fifths and at most 998 in every 1000 people with a positive RT-qPCR test result with high viral load. Conclusions The Innova LFT can be useful for identifying infections among adults who report no symptoms of covid-19, particularly those with high viral load who are more likely to infect others. The number of asymptomatic adults with lower Ct (indicating higher viral load) missed by LFT, although small, should be considered when using single LFT in high consequence settings. Clear and accurate communication with the public about how to interpret test results is important, given the chance of missing some cases, even at high viral loads. Further research is needed to understand how infectiousness is reflected in the viral antigen shedding detected by LFT versus the viral loads approximated by RT-qPCR.


Author(s):  
Zhanchong Shi ◽  
Qingtian Su ◽  
Xinyi He ◽  
Quanlu Wang ◽  
Kege Zhou ◽  
...  

<p>In order to solve the construction problem of perforating rebars’ precise location and it’s getting through the circular holes for the the conventional perfobond connector, a new type of perfobond connector with boot shaped slots was proposed. This new type perfobond connector has the advantage of convenient construction and pricise location. Three groups of push-out tests with nine specimens were carried out to study the shear capacity of the new type perfobond connector. The effect of the number and the spacing of boot shaped slots on failure modes, shear capacity, peak slip and shear stiffness were mainly studied. The test results show that the new type of perfobond connector with boot shaped slots has a high shear capacity and a good ductility, it could be widely applied on the connection between the steel and the concrete structures.</p>


2013 ◽  
Vol 275-277 ◽  
pp. 1911-1914 ◽  
Author(s):  
Han Jun Hu ◽  
Hui Zhou ◽  
Yu Gang Zheng ◽  
Kai Feng Zhang ◽  
Zhi Hua Wan

The bonded MoS2 films are widely used as solid lubricants in aerospace mechanisms due to their excellent tribological properties. Traditionally, the MoS2 was directly bonded on the Al substrate that was only treated by the technique named of sandblast. For improving the tribological properties of MoS2 films, micro arc oxidation (MAO) instead of sandblast was introduced as a new technique for treating of Al substrate. In this article, the tribological properties of MoS2 films which were bonded on different surface of Al substrate as mentioned above were discussed, respectively. It was concluded from the test results that the MoS2 films bonded on substrate treated by MAO have better tribological properties than those samples treated by sandblast. The endurance life against abrasion of the former is as high as twenty times of the latter by the stand test method of ball on disk using the UMT Multi-Specimen Test System. This test results could be illustrated by the following reasons. The first is the porous microstructures of MAO ceramic coatings on the Al substrate. The coatings have numerous pits to be good at increasing the binding force with the MoS2 films, and the pits can also provide a MoS2 lubricants reservoir during processes of friction. Both of them improved the MoS2 film’s ability of wear-protective. The second is that hardness of the coating is higher than the Al, and this ensures well wearing resistance, especially in practical application to big load-supporting moving parts, such as bearing, gear, etc…


Sign in / Sign up

Export Citation Format

Share Document