scholarly journals Keraring Intrastromal Segment Depth Measured by Spectral-Domain Optical Coherence Tomography in Eyes with Keratoconus

2017 ◽  
Vol 2017 ◽  
pp. 1-9
Author(s):  
Ugo de Sanctis ◽  
Carlo Lavia ◽  
Marco Nassisi ◽  
Savino D’Amelio

Purpose. To evaluate agreement between measured and intended distance of Keraring (Mediphacos, Belo Horizonte, Brazil) intracorneal ring segments from the anterior and posterior corneal surfaces.Methods. Twenty-six Keraring ICRS implanted in 24 keratoconic eyes were examined. The distance from the Keraring apex to the anterior corneal surface and the distance from the inner and the outer corners to the posterior corneal surface were measured 3 months postoperatively using spectral-domain optical coherence tomography. Agreement between measured distance and intended distance was assessed by calculating the absolute differences and 95% limits of agreement (95% LoA).Results. The mean absolute difference was significantly lower (p<0.001) for the measurements taken at the inner corner (23.54±15.90 μm) than that for those taken at the apex (108.92±62.72 μm) and the outer corner (108.35±56.99 μm). The measurements taken at the inner corner were within ±25 and ±50 μm of the intended distance in 15/26 (57.7%) and 24/26 (92.3%) cases, respectively, and showed the narrowest 95% LoA with the intended distance (−57.61 to 55.15 μm).Conclusions. The distance of the inner corner from the posterior corneal surface showed the best agreement with the intended distance. This measurement is suitable for determining whether the actual Keraring depth matches the intended depth.

Biology ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 273
Author(s):  
Marc Schargus ◽  
Catharina Busch ◽  
Matus Rehak ◽  
Jie Meng ◽  
Manuela Schmidt ◽  
...  

The aim of this study was to compare the efficacy of trabeculectomy (TE), single XEN microstent implantation (solo XEN) or combined XEN implantation and cataract surgery (combined XEN) in primary open-angle glaucoma cases, naïve to prior surgical treatment, using a monocentric retrospective comparative cohort study. Intraocular pressure (IOP) and the number of IOP-lowering drugs (Meds) were monitored during the first 24 months after surgery. Further disease progression was monitored using peripapillary retinal nerve fiber layer (RNFL) thickness examinations using spectral domain optical coherence tomography (OCT) as well as visual acuity (VA) and visual field (VF) tests. In the TE group (52 eyes), the mean IOP decreased from 24.9 ± 5.9 to 13.9 ± 4.2 mmHg (p < 0.001) and Meds decreased from 3.2 ± 1.2 to 0.5 ± 1.1 (p < 0.001). In the solo XEN (38 eyes) and the combined XEN groups, the mean IOP decreased from 24.1 ± 4.7 to 15.7 ± 3.0 mmHg (p < 0.001) and 25.4 ± 5.6 to 14.7 ± 3.2 mmHg (p < 0.001), while Meds decreased from 3.3 ± 0.8 to 0.8 ± 1.2 (p < 0.001) and 2.7 ± 1.2 to 0.4 ± 1.0 (p < 0.001), respectively. The VF and VA indices showed no sign of further deterioration, the RNFL thickness further decreased in all treatment groups after surgery. TE and XEN led to comparable reductions in IOP and Meds. Although the VA and VF indices remained unaltered, the RNFL thickness continuously decreased in all treatment groups during the 24-month follow-up.


2015 ◽  
Vol 08 (04) ◽  
pp. 1550012 ◽  
Author(s):  
Qinqin Zhang ◽  
Maureen Neitz ◽  
Jay Neitz ◽  
Ruikang K. Wang

Purpose: To provide a geographical map of choroidal thickness (CT) around the macular region among subjects with low, moderate and high myopia. Methods: 20 myopic subjects (n = 40 eyes) without other identified pathologies participated in this study: 20 eyes of ≤ 3 diopters (D) (low myopic), 10 eyes between -3 and -6D (moderate myopic), and 10 eyes of ≥ 6D (high myopic). The mean age of subjects was 30.2 years (± 7.6 years; range, 24 to 46 years). A 1050 nm spectral-domain optical coherence tomography (SD-OCT) system, operating at 120 kHz imaging rate, was used in this study to simultaneously capture 3D anatomical images of the choroid and measure intraocular length (IOL) in the subject. The 3D OCT images of the choroid were segmented into superior, inferior, nasal and temporal quadrants, from which the CT was measured, representing radial distance between the outer retinal pigment epithelium (RPE) layer and inner scleral border. Measurements were made within concentric regions centered at fovea centralis, extended to 5 mm away from fovea at 1 mm intervals in the nasal and temporal directions. The measured IOL was the distance from the anterior cornea surface to the RPE in alignment along the optical axis of the eye. Statistical analysis was performed to evaluate CT at each geographic region and observe the relationship between CT and the degree of myopia. Results: For low myopic eyes, the IOL was measured at 24.619 ± 0.016 mm. The CT (273.85 ± 49.01 μm) was greatest under fovea as is in the case of healthy eyes. Peripheral to the fovea, the mean CT decreased rapidly along the nasal direction, reaching a minimum of 180.65 ± 58.25μm at 5 mm away from the fovea. There was less of a change in thickness from the fovea in the temporal direction reaching a minimum of 234.25 ± 42.27 μm. In contrast to the low myopic eyes, for moderate and high myopic eyes, CTs were thickest in temporal region (where CT = 194.94 ± 27.28 and 163 ± 34.89 μm, respectively). Like the low myopic eyes, moderate and high myopic eyes had thinnest CTs in the nasal region (where CT = 100.84 ± 16.75 and 86.64 ± 42.6μm, respectively). High myopic eyes had the longest mean IOL (25.983 ± 0.021mm), while the IOL of moderate myopia was 25.413 ± 0.022 mm (**p < 0.001). The CT reduction rate was calculated at 31.28 μm/D (diopter) from low to moderate myopia, whilst it is 13.49 μm/D from moderate to high myopia. The similar tendency was found for the IOL reduction rate in our study: 0.265 mm/D from low to moderate myopia, and 0.137 mm/D from moderate to high myopia. Conclusion: The CT decreases and the IOL increases gradually with the increase of myopic condition. The current results support the theory that choroidal abnormality may play an important role in the pathogenesis of myopic degeneration.


2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Ozen Ayrancı Osmanbasoglu ◽  
Zeynep Alkin ◽  
Abdullah Ozkaya ◽  
Yavuz Ozpınar ◽  
Ahmet Taylan Yazici ◽  
...  

Purpose. To analyse the diurnal variation of central choroidal thickness (CCT) in healthy emetropic patients during working hours.Methods. Fifty healthy young emmetrpic volunteers were included in this study. CCT was measured at 9 AM and 4 PM with spectral domain optical coherence tomography (Spectralis, Heidelberg Engineering) with enhanced depth imaging. Diurnal variation of CCT, the correlation between rigth and left eyes and the demographic factors affecting this variation were assessed.Findings. The mean CCT at 9 AM and 4 PM was 308.7 ± 64.5 μm and 308.7 ± 62 μm, respectively, with a mean diurnal amplitude of −0.03 ± 14.7 μm, ranging between −55 μm and 47 μm, the difference was statistically insignificant (P: 0.9). There were positive correlations between right and left eyes among CCT measurements at 9 AM, 4 PM and the mean amplitude of diurnal change (r: 0.65,P<0.01;r: 0.60,P<0.01;r: 0.45,P: 0.00, resp.). There was a statistically significant negative correlation between the magnitude of diurnal change and age (r: −0.27,P: 0.01).Conclusion. Although the mean CCT in the all group does not show significant variation during working hours, the pattern of diurnal variation may vary from person to person according to age, and there is a great harmony between the two eyes.


Author(s):  
Pasha Anvari ◽  
Amin Najafi ◽  
Reza Mirshahi ◽  
Mahsa Sardarinia ◽  
Maryam Ashrafkhorasani ◽  
...  

Purpose: To compare the area of the foveal avascular zone (FAZ) in the superficial and deep retinal layers using two different spectral-domain optical coherence tomography angiography (OCTA) devices. Methods: A cross-sectional comparative study was conducted to obtain macular OCTA images from healthy subjects using Optovue RTVue XR Avanti (Optovue, Inc, Fremont, CA) and Spectralis HRA+OCTA (Heidelberg Engineering, Heidelberg, Germany). Two independent trained graders measured the FAZ area using automated slab segmentation. The FAZ area in the superficial and deep retinal layers were compared. Results: Twenty-three eyes of 23 subjects were included. The graders agreement was excellent (>0.86) for all measurements. The mean FAZ area was significantly larger at the superficial retinal layer as compared to the deep retinal layer on both devices (0.31 ± 0.08 mm2 vs 0.26 ± 0.08 mm2 in Optovue and 0.55 ± 0.16 mm2 vs 0.36 ± 0.13 mm2 in Spectralis, both P < 0.001). The mean FAZ area was significantly greater in the superficial and deep retinal layers using Spectralis as compared to Optovue measurements (P < 0.001 for both comparisons). Conclusion: In contrast to previous reports, the FAZ area was larger in the superficial retina as compared to deep retinal layers using updated software versions. Measurements from different devices cannot be used interchangeably.


2021 ◽  
pp. 112067212110637
Author(s):  
Rania S Elkitkat ◽  
Yasser Rifay ◽  
Hesham M Gharieb ◽  
Hossam Eldin A Ziada

Purpose To determine the normative and the cut-off values of various indices available in the MS 39 Anterior Segment Optical Coherence Tomography (MS-39 AS-OCT) for keratoconus (KC) diagnosis, and to detect the accuracy of the variable available parameters. Methods This cross sectional observational study was conducted at Dr Rifay Ophthalmology Center, Rabat, Morocco, on 172 eyes with KC (group 1) and 248 eyes of healthy controls (group 2). Participants were screened using MS-39 AS-OCT (CSO, Firenze, Italy). The investigated indices included: keratometric indices, pachymetric indices, elevation indices, Keratoconus Summary Indices (KSI), aberration indices, and epithelial mapping evaluation. Results Most of the studied indices were significantly different between both groups (P value <0.001). Twenty two indices had Area Under the Receiver Operating Curve (AUROC) values >0.950, eight of which were from the KSI. The indices with the highest AUROC values were: Root Mean Square (RMS) for the front corneal surface at 6 mm circle (AUROC = 0.996, and best cut-off >1.69 with sensitivity of 97.67% and specificity of 97.98%) and RMS per unit of area for the front surface at 6 mm circle (AUROC = 0.996, and best cut-off >0.06 with sensitivity of 97.67% and specificity of 97.98%). Epithelial thickness-derived metrics were not among the parameters with the highest accuracy. Conclusions This study presented the mean and the cut-off values for a plethora of parameters available in the MS-39 AS-OCT. The results of this study show that MS-39 AS-OCT is a valuable equipment for diagnosing keratoconic corneas, with a high accuracy detected for many parameters.


2014 ◽  
Vol 6 (2) ◽  
pp. 131-139 ◽  
Author(s):  
Madhu Thapa ◽  
Safal Khanal ◽  
Gulsan B Shrestha ◽  
Ananda K Sharma

Objective: To determine the normal values for peripapillary retinal nerve fibre layer thickness (RNFL) measured by spectral domain optical coherence tomography (SD- OCT) in a healthy Nepalese population and to compare the RNFL thicknesses between the genders and among the various age groups.Material and methods: One hundred and fifty six eyes of 156 healthy Nepalese subjects (66 males and 88 females) of various age groups were enrolled in this observational, cross-sectional, hospital-based study. The peripapillary RNFL of the randomly chosen eye of each subject was imaged with a high resolution SD-OCT (Spectralis HRA+OCT, Heidelberg Engineering). The RNFL thickness was measured around the optic nerve head using 16 automatically averaged, consecutive, circular B scans with a 3.4 mm diameter and compared between the genders and among the various age groups.Results: The mean age of the subjects was 38.94 ± 17.00 years (range - 14 to 76 years). The average peripapillary RNFL was found to be 102.64 ± 9.56 μm (95 % CI 97.01 - 101.93). The mean ± SD peripapillary RNFL measurements at the superior, nasal, inferior and temporal sectors in the study population were 129.51 ± 15.09 μm, 76.55 ± 12.02 μm, 134.53 ± 17.19 μm and 70.74 ± 15.53 μm respectively. The average RNFL thickness was 99.47 ± 10.18 μm in the male whereas it was 105.09 ± 8.31 μm in the female participants. The RNFL decreased by 2.26 μm per age per decade.  Conclusion: The Average RNFL thickness is 102.64 ± 9.56 μm in the Nepalese population. Gender and age related variation in the RNFL could serve as a useful guideline in the diagnosis of glaucoma in our population.DOI: http://dx.doi.org/10.3126/nepjoph.v6i2.11709Nepal J Ophthalmol 2014; 6(12): 131-139 


2021 ◽  
pp. 112067212110087
Author(s):  
Oluwaseun Olaniyi Awe ◽  
Oluwatoyin Helen Onakpoya ◽  
Adenike Odunmorayo Adeoye

Purpose: To assess morphological optic disc dimensions using spectral-domain optical coherence tomography (OCT) in a Nigerian population. Materials and method: Good quality SD-OCT scans of the optic disc of 147 eyes of 88 participants were selected, enrolled, and retrospectively reviewed. All subjects had optic nerve head and retinal nerve fibre layer OCT imaging, as well as analysis, done using the Topcon 3D OCT-1 Maestro®. The age, sex, and some OCT-generated optic disc dimensions namely disc area (DA), vertical disc diameter (VDD), horizontal disc diameter (HDD) were retrieved from the database and analyzed. Results: The mean age of the study subjects was 52.6±20.9 years with a range of 8–90 years; male to female ratio was 1:1.3. The right eye and left eye accounted for 75 and 72 of the 147 scans respectively. The mean DA, VDD, and HDD were 2.54 ± 0.48 mm2, 1926.5 ± 189.6 μm and 1673.9 ± 173.9 μm, respectively. Males had significantly larger DA than females (2.56 ± 0.53 mm2 vs 2.51 ± 0.44 mm2, p = 0.043). The mean DA and VDD of eyes of subjects aged 21–40 years were significantly higher compared to subjects aged 60 years and more ( p = 0.008 and 0.001, respectively). Conclusion: The mean optic disc area and diameters are larger than those reported in similar studies involving blacks and other races. The mean disc area reduces with increasing age.


2017 ◽  
Vol 24 (2) ◽  
pp. 93-100
Author(s):  
Aistė Kadziauskienė ◽  
Ernesta Strelkauskaitė ◽  
Eglė Mockevičiūtė ◽  
Rimvydas Ašoklis ◽  
Eugenijus Lesinskas ◽  
...  

Conflict of interest. None of the authors have any conflict of interest to declare, financial or otherwise. No financial or other support was received for the study. Background. The  aim of the  study was to assess changes in macular thickness after trabeculectomy in respect to the  use of 5-fluorouracil (5-FU) as well as to analyse possible associations between the  postoperative changes in macular thickness and intraocular pressure (IOP). Materials and methods. The prospective observational study included 106 eyes (100 patients) with glaucoma who underwent trabeculectomy with or without 5-FU. Subsequently 5-FU needling was performed if failure of the  filtrating bleb occurred. Macular thickness and the  IOP were evaluated before, one week, and six months after the surgery. The mean and sectoral macular thickness was assessed using spectral domain optical coherence tomography. Results. The mean (±SD) IOP reduced from 27.71 (±6.88) mmHg at baseline to 18.3  (±8.1)  mmHg one week (p 


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Riham S. H. M. Allam ◽  
Mai N. Abd-Elmohsen ◽  
Mohamed M. Khafagy ◽  
Karim A. Raafat ◽  
Sherif M. Sheta

Purpose. To evaluate the role of spectral-domain optical coherence tomography (SD-OCT) in early detection of Chloroquine maculopathy in rheumatoid arthritis (RA) patients.Methods. 40 left eyes of 40 female rheumatoid arthritis patients who received treatment chloroquine for more than one year were recruited in the study. All patients had no symptoms or signs of Chloroquine retinopathy. They were evaluated using SD-OCT, where the Central Foveal Thickness (CFT), parafoveal thickness and perifoveal thickness, average Retinal Nerve Fiber Layer (RNFL) thickness, and Ganglion Cell Complex (GCC) measurements were measured and compared to 40 left eyes of 40 normal females.Results. The mean CFT was found to be thinner in the Chloroquine group (238.15 µm ± 22.49) than the normal controls (248.2 µm ± 19.04), which was statistically significant (pvalue = 0.034). The mean parafoveal thickness was lesser in the Chloroquine group than the control group in all quadrants (pvalue<0.05). The perifoveal thickness in both groups showed no statistically significant difference (pvalue>0.05) in all quadrants. No significant difference was detected between the two groups regarding RNFL, GCC, or IS/OS junction.Conclusions. Preclinical Chloroquine toxicity can lead to early thinning in the central fovea as well as the parafoveal regions that is detected by SD-OCT.


2012 ◽  
Vol 2012 ◽  
pp. 1-5 ◽  
Author(s):  
Masashi Kakinoki ◽  
Taichirou Miyake ◽  
Osamu Sawada ◽  
Tomoko Sawada ◽  
Hajime Kawamura ◽  
...  

Purpose. To compare the macular thicknesses in diabetic macular edema (DME) measured with spectral-domain optical coherence tomography (SD-OCT) and time-domain (TD) OCT.Patients and Methods.The average macular thicknesses of 50 eyes of 29 patients with DME were measured using SD-OCT and TD-OCT.Results.The mean macular thicknesses measured with TD-OCT and SD-OCT were401.5±117.8 μm (mean ± SD) and446.2±123.5 μm, respectively. The macular thicknesses measured with the two devices were well correlated (Pearson's product moment correlation,r=0.977,P<0.001). A significant correlation was found between the best-corrected visual acuity and the retinal thickness measured by TD-OCT and SD-OCT (Pearson's product moment correlation, TD-OCT,r=0.34;P<0.05; SD-OCT,r=0.32;P<0.05).Discussion.The mean macular thickness measured with SD-OCT was about 45 μm thicker than that measured with TD-OCT. Attention should be paid when comparing data obtained using different OCT machines.