scholarly journals Fungicidal, Corrosive, and Mutational Effects of Polyhexamethylene Biguanide Combined with 1-Bromo-3-chloro-5,5-dimethylimidazolidine-2,4-dione

2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Bing Niu ◽  
Wan Huai ◽  
Zhirui Deng ◽  
Qin Chen

Background. The disinfectants polyhexamethylene biguanide (PHMB) and 1-bromo-3-chloro-5,5-dimethylimidazolidine-2,4-dione (BCDMH) each have limitations. So far, their combined usage has not been examined. In this study, the fungicidal activity of combined disinfectant using PHMB and BCDMH, named PB, against Candida albicans was evaluated. Methods. Suspension quantitative fungicidal test and viable fungi count were used to test fungicidal effects against C. albicans. Coupon corrosion testing was used to evaluate disinfectants’ corrosive effects on stainless steel, copper, and aluminum. The mouse lymphoma assay was used to detect mutations induced by PB. Results and Discussion. Fungicidal activity of the combination of 40 mg/L PHMB and 40 mg/L BCDMH was comparable to, or even better than, those of 600 mg/L PHMB or 640 mg/L BCDMH alone. The combination of 400 mg/L PHMB and 400 mg/L BCDMH exhibited good fungicidal effects in field applications. The combination of 100 mg/L PHMB and 100 mg/L BCDMH did not have corrosive effects on stainless steel and no mutagenic effect was observed under the test conditions. Conclusions. The combination of PHMB and BCDMH has strong fungicidal effects and little metal corrosive and mutagenic effect and can be used as one suitable fungicide for wide household and industrial applications, including shipping containers.

Alloy Digest ◽  
2003 ◽  
Vol 52 (9) ◽  

Abstract Crucible CPM S30V is a martensitic stainless steel designed with a combination of toughness, wear resistance, and corrosion resistance equal to or better than 440C. This datasheet provides information on composition, physical properties, microstructure, hardness, and elasticity as well as fracture toughness. It also includes information on corrosion and wear resistance as well as heat treating and machining. Filing Code: SS-891. Producer or source: Crucible Service Centers.


Alloy Digest ◽  
1994 ◽  
Vol 43 (5) ◽  

Abstract URANUS 52N is a nitrogen-alloyed duplex stainless steel improved in stress-corrosion cracking resistance and with pitting and crevice corrosion resistance better than AISI Type 317L. Applications include handling phosphoric acid contaminated with chlorides and in flue gas desulfurization scrubbers. This datasheet provides information on composition, physical properties, and tensile properties. It also includes information on high temperature performance and corrosion resistance as well as forming, heat treating, and joining. Filing Code: SS-566. Producer or source: Creusot-Marrel.


2008 ◽  
Vol 21 (02) ◽  
pp. 140-146
Author(s):  
M. R. Edwards ◽  
S. P. James ◽  
W. S. Dernell ◽  
R. J. Scott ◽  
A. M. Bachand ◽  
...  

SummaryThe biomechanical characteristics of 1.2 mm diameter allogeneic cortical bone pins harvested from the canine tibia were evaluated and compared to 1.1 mm diameter stainless steel pins and 1.3 mm diameter polydioxanone (PDS) pins using impact testing and four-point bending. The biomechanical performance of allogeneic cortical bone pins using impact testing was uniform with no significant differences between sites, side, and gender. In four-point bending, cortical bone pins harvested from the left tibia (204.8 ± 77.4 N/mm) were significantly stiffer than the right tibia (123.7 ± 54.4 N/mm, P=0.0001). The site of bone pin harvest also had a significant effect on stiffness, but this was dependent on interactions with gender and side. Site C in male dogs had the highest mean stiffness in the left tibia (224.4 ± 40.4 N/mm), but lowest stiffness in the right tibia (84.9 ± 24.2 N/mm). Site A in female dogs had the highest mean stiffness in the left tibia (344.9 ± 117.4 N/mm), but lowest stiffness in the right tibia (60.8 ± 3.7 N/mm). The raw and adjusted bending properties of 1.2 mm cortical bone pins were significantly better than 1.3 mm PDS pins, but significantly worse than 1.1 mm stainless steel pins (P<0.0001). In conclusion, cortical bone pins may be suitable as an implant for fracture fixation based on initial biomechanical comparison to stainless steel and PDS pins used in clinical practice.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


2014 ◽  
Vol 8 (3) ◽  
pp. 156-159 ◽  
Author(s):  
Magdalena Łępicka ◽  
Małgorzata Grądzka-Dahlke

Abstract Martensitic stainless steels are used in a large number of various industrial applications, e.g. molds for plastic injections and glass moldings, automotive components, cutting tools, surgical and dental instruments. The improvement of their tribological and corrosion properties is a problem of high interest especially in medical applications, where patient safety becomes a priority. The paper covers findings from plasma nitrided AISI 440B (PN-EN or DIN X90CrMoV18) stainless steel corrosion resistance studies. Conventionally heat treated and plasma nitrided in N2:H2 reaction gas mixture (50:50, 65:35 and 80:20, respectively) in two different temperature ranges (380 or 450°C) specimens groups were examined. Microscopic observations and electrochemical corrosion tests were performed using a variety of analytical techniques. As obtained findings show, plasma nitriding of AISI 440B stainless steel, regardless of the process temperature, results in reduction of corrosion current density. Nevertheless, applying thermo-chemical process which requires exceeding temperature of about 400°C is not recommended due to increased risk of steel sensitization to intergranular and stress corrosion. According to the results, material ion nitrided in 450°C underwent leaching corrosion processes, which led to significant disproportion in chemical composition of the corroded and corrosion-free areas. The authors suggest further research into corrosion process of plasma nitrided materials and its degradation products.


1977 ◽  
Vol 99 (2) ◽  
pp. 126-132 ◽  
Author(s):  
L. K. Ives

Erosion tests were conducted on 310 stainless steel in combustion gas atmospheres at 975°C. SiC particles of 100 mesh (150 μm) size were employed over a velocity range of 15–70 m/s at a 90 deg (perpendicular) angle of impingement. A comparison is made with results obtained at 25°C in air using the same test equipment. Scanning electron microscopy examination of the eroded surfaces revealed important information concerning the nature of the erosion-corrosion process. A multiple component test specimen is described for application in comparing alloys under nearly identical test conditions.


2020 ◽  
Vol 7 (6) ◽  
pp. 619-625
Author(s):  
Jianfeng Shi ◽  
Huan Lian ◽  
Yuanli Huang ◽  
Danmei Zhao ◽  
Han Wang ◽  
...  

Abstract Glutaraldehyde (GA) is an important additive that is mainly used in animal-derived biomaterials to improve their mechanical and antimicrobial capacities. However, GA chemical toxicity and the metabolic mechanism remain relatively unknown. Therefore, residual GA has always been a major health risk consideration for animal-derived medical devices. In this study, extracts of three bio-patches were tested via the GA determination test and mouse lymphoma assay (MLA). The results showed that dissolved GA was a potential mutagen, which could induce significant cytotoxic and mutagenic effects in mouse lymphoma cells. These toxic reactions were relieved by the S9 metabolic activation (MA) system. Furthermore, we confirmed that GA concentration decreased and glutaric acid was generated during the catalytic process. We revealed GA could be oxidized via cytochrome P450 which was the main metabolic factor of S9. We found that even though GA was possibly responsible for positive reactions of animal-derived biomaterials’ biocompatibility evaluation, it may not represent the real situation occurring in human bodies, owing to the presence of various detoxification mechanisms including the S9 system. Overall, in order to achieve a general balance between risk management and practical application, rational decisions based on comprehensive analyses must be considered.


Author(s):  
Azzeddine Ferrah ◽  
Mounir Bouzguenda ◽  
Jehad M. Al-Khalaf Bani Younis

Large and small single-phase and three-phase induction motors are commonly used in industrial applications. The present work represents an attempt towards the design of a high accuracy system for the measurement of fractional horsepower (FHP) induction motor losses and efficiency. The calorimeter designed and built is capable of measuring heat losses of up to 1 kW with an overall accuracy better than 3%. During all tests, ambient temperature, humidity, motor speed and motor frame temperature were recorded using precise digital instruments. The inlet, outlet temperatures and resulting losses were recorded automatically using a high accuracy 12-bit data acquisition system. The preliminary results obtained demonstrate the suitability of the designed calorimeter for the accurate measurement of losses in FHP induction motors.


Sign in / Sign up

Export Citation Format

Share Document