scholarly journals Impacted Metallic Spring Requiring Cervical Esophagotomy: A Case Report and Review of the Literature on Foreign Body Removal

2017 ◽  
Vol 2017 ◽  
pp. 1-3
Author(s):  
Patrick Stoner ◽  
Eric Hilgenfeldt ◽  
Alexander Schlachterman

Foreign body ingestion is a commonly encountered problem and can cause significant morbidity and mortality. When removal of a foreign body from the upper gastrointestinal tract is indicated, endoscopy is the modality of choice and has a high reported success rate. However, in less than 1% of cases, endoscopic removal of a foreign body is unsuccessful and surgical intervention is necessary. We report a unique case of a large, sharp metallic spring swallowed by an incarcerated patient which subsequently became lodged in his upper thoracic esophagus. This spring was unable to be removed endoscopically due to risk of perforation and cervical esophagotomy was needed for its successful removal, illustrating the limitations of endoscopic techniques in removal of foreign bodies and the role surgical intervention has in these rare instances.

2016 ◽  
Vol 2016 ◽  
pp. 1-4 ◽  
Author(s):  
Ismael Garcia ◽  
Joseph Varon ◽  
Salim Surani

Introduction. Foreign body impaction (FBI) in the esophagus can be a serious condition, which can have a high mortality among children and adults, if appropriate diagnosis and treatment are not instituted urgently. 80–90% of all foreign bodies trapped in the esophagus usually pass spontaneously through the digestive tract, without any medical or surgical intervention. 10–20% of them will need an endoscopic intervention.Case Report. We hereby present a case of a large chicken piece foreign body impaction in the esophagus in a 25-year-old male with mental retardation. Patient developed hypoxemic respiratory failure requiring intubation. The removal required endoscopic intervention.Conclusions. Foreign bodies trapped in the upper gastrointestinal tract are a serious condition that can be fatal if they are not managed correctly. A correct diagnosis and treatment decrease the chances of complications. Endoscopic treatment remains the gold standard for extracting foreign body impaction.


2004 ◽  
Vol 4 ◽  
pp. 56-58 ◽  
Author(s):  
Andy Y. Chang ◽  
Chester J. Koh ◽  
John P. Stein

The management of urethral foreign bodies may require the use of various surgical techniques in a urologist's armamentarium. We report a unique case of a urethral foreign body requiring percutaneous and endoscopic techniques for removal.


2018 ◽  
Vol 2018 ◽  
pp. 1-3
Author(s):  
Naima Baddouh ◽  
Lahcen Arjdal ◽  
Abdelaziz Raji ◽  
Mounir Bourrous

Summary. Foreign bodies in esophagus are avoidable accidents that occur most often in children younger than 3 years. The most common presenting symptoms are dysphagia, drooling, and vomiting. Revelation by respiratory distress is a rare and unusual condition. Objective. We describe and discuss the case of an esophageal foreign body, in which the patient presented with respiratory distress. Case report. A two-year-old child was admitted to the emergency department for acute respiratory distress. He had no history of choking episodes or dysphagia. Nevertheless, he was brought by his parents several times for a persistent cough and wheezing that was treated as asthma for a month. Pulmonary examination had revealed polypnea, suprasternal recession, scattered snoring, and diffuse wheeze. As part of his assessment, a chest X-ray was demanded. It had shown, as unexpected, a nonmetallic foreign body in the upper thoracic esophagus. A clothing button was removed by hypopharyngoscopy under sedation without any incident. Subsequent follow-up had not shown any complications related to this episode. Conclusion. Large esophageal foreign bodies can impinge on the trachea causing upper respiratory tract signs. We alert clinicians on variation in the presentation of foreign body ingestion, and we emphasize the importance of an early diagnosis and management.


1996 ◽  
Vol 105 (7) ◽  
pp. 555-561 ◽  
Author(s):  
C. Anthony Hughes ◽  
Fuad M. Baroody ◽  
Bernard R. Marsh

We investigated changing trends in pediatric tracheobronchial foreign body removal and resident experience from 1939 to 1991. We retrieved the records of 234 cases of tracheobronchial foreign body removal at Johns Hopkins. The mean number of cases per year was 5.9. The most common foreign bodies removed were peanuts, accounting for 38.9%. The average yearly incidence of pediatric tracheobronchial foreign bodies remained relatively constant during the period studied. Our data suggested little change in outcome or complications with the advent of optical telescopes in the mid-1970s, despite their great value in improved visualization. Resident experience and training were evaluated by the number of cases attended by each resident during his or her training. The number varied from 1 to 8 cases, not including experience acquired at our sister institutions. Although complete data could not be obtained in many of the older medical records, our review suggests that despite the advantage offered by the optical forceps technology, proper training and experience in traditional rigid endoscopic techniques is still crucial to optimize outcome and minimize the risk of complications in pediatric tracheobronchial foreign body removal. Chevalier Jackson's recommendation that residency training include an animal laboratory course in foreign body removal still applies.


2020 ◽  
Vol 4 (3) ◽  
pp. 450-453
Author(s):  
Samuel Nesemann ◽  
Kimberly Hubbard ◽  
Mehdi Siddiqui ◽  
William Fernandez

Introduction: Rectal foreign bodies (RFB) pose a challenge to emergency physicians. Patients are not often forthcoming, which can lead to delays to intervention. Thus, RFBs require a heightened clinical suspicion. In the emergency department (ED), extraction may require creative methods to prevent need for surgical intervention. Case Report: The authors present a case of a successful extraction of a RFB in the ED and review of the literature. Conclusion: Retained RFBs are an unusually problematic reason for an ED visit. Thus, it is important for emergency physicians to be comfortable managing such cases appropriately.


Author(s):  
P D Chakravarty ◽  
T Kunanandam ◽  
G Walker

Abstract Background Ingested foreign bodies are a common presentation to paediatric ENT services. Depending on the site, these are usually managed with flexible or rigid oesophagoscopy and retrieval. This paper presents a novel technique for removing a hollow foreign body that could not be removed using conventional means. Method and results After rigid and flexible approaches failed, a guidewire was passed through the foreign body under fluoroscopic guidance and a dilatation balloon passed through the lumen of the object. Inflating the balloon allowed dilatation of the inflamed mucosa above and below the object, facilitating straightforward removal under traction. Conclusion This is a novel and reproducible technique that uses equipment readily available in tertiary referral centres. Employed in this context, the technique enabled removal of an impacted object surrounded by granulation tissue, and would be appropriate for other objects with a lumen.


2015 ◽  
Vol 30 (1) ◽  
pp. 106-113 ◽  
Author(s):  
Ho-Jun Lee ◽  
Hyun-Soo Kim ◽  
Jin Jeon ◽  
Sang-Hun Park ◽  
Sung-Uk Lim ◽  
...  

2014 ◽  
Vol 129 (1) ◽  
pp. 93-94 ◽  
Author(s):  
W Nivatvongs ◽  
M Ghabour ◽  
G Dhanasekar

AbstractBackground:Removing a button battery from the ear can be a tricky and challenging procedure.Method and Results:We describe the innovative use of a magnetic telescopic rod to successfully remove a button battery from the ear canal of a nine-year-old boy.Conclusion:We propose that this equipment should be available in ENT clinics and operating theatres to be used for removing foreign bodies made from ferrous materials.


2017 ◽  
Vol 4 (10) ◽  
pp. 3277
Author(s):  
Pramod Mirji ◽  
Vikas Daddenavar ◽  
Eshwar Kalburgi

Background: Foreign body ingestion and food bolus impaction is a common clinical scenario and can present as an endoscopic emergency. Though majority of them pass spontaneously 10-20% require endoscopic intervention. Flexible endoscopy is recommended as therapeutic measure with minimal complications. The aim of our study is to present 2 years’ experience in dealing with foreign bodies in the upper gastrointestinal tract.Methods: Cases of foreign body (FB) ingestion admitted to department of general surgery from January 2015 to December 2016 were evaluated. The patients were reviewed with details on age, sex, type of FB, its location in gastrointestinal tract, treatment and outcome.Results: A total of 23 cases were studied. Age range was 2-75 years. Males were predominant (60.87%). Coins were found most commonly (52.17%). Esophagus was the commonest site of FB lodgment (65.22%). Upper esophagus being the most common (39.13%). Upper gastrointestinal flexible endoscopy was useful in retrieving FB in all the 23 cases. There were no complications throughout the study period.Conclusions: Flexible endoscopy should be used as definitive treatment and endoscopic treatment is safe and effective. 


2014 ◽  
Vol 24 (02) ◽  
pp. 196-200
Author(s):  
Morteza Tahmasebi ◽  
Hamdollah Zareizadeh ◽  
Azim Motamedfar

Abstract Background and Objective: Detection of radiolucent soft-tissue foreign bodies is a challenging problem, which is especially further complicated when retained foreign body is highly suggested by clinicians but radiography is negative. So, blind exploration is sometimes hazardous for patients. The purpose of this study was to determine the accuracy of ultrasonography (USG) in detecting radiolucent soft-tissue foreign bodies in the extremities. Materials and Methods: From November 2011 to January 2012, patients with clinically suspected radiolucent soft-tissue foreign body and negative radiography were evaluated by USG with a 12-MHz linear array transducer. The patients with positive clinical and USG examination were included in our study and underwent exploration or USG removal. Results: Fifty-one patients underwent foreign body removal under ultrasonography-guided or surgical exploration and 47 patients had foreign body (31, 12, 3, and 1 case had thorn, wood, glass, and plastic, respectively). Ultrasound was positive in 50 patients. USG falsely predicted the presence of foreign body in four cases and was falsely negative in one of the cases. Accuracy, sensitivity, and positive predictive value were determined as 90.2%, 97.9%, and 92%, respectively. Conclusions: The real-time high-frequency USG is a highly sensitive and accurate tool for detecting and removing radiolucent foreign bodies which are difficult to be visualized by routine radiography.