scholarly journals Comparison of Common Methods for Precision Volume Measurement of Hematoma

2020 ◽  
Vol 2020 ◽  
pp. 1-11
Author(s):  
Minhong Chen ◽  
Zhong Li ◽  
Jianping Ding ◽  
Xingqi Lu ◽  
Yinan Cheng ◽  
...  

Purpose. Our aim is to conduct analysis and comparison of some methods commonly used to measure the volume of hematoma, for example, slice method, voxelization method, and 3D-Slicer software method (projection method). Method. In order to validate the accuracy of the slice method, voxelization method, and 3D-Slicer method, these three methods were first applied to measure two known volumetric models, respectively. Then, a total of 198 patients diagnosed with spontaneous intracerebral hemorrhage (ICH) were recruited. The patients were split into 3 different groups based on the hematoma size: group 1: volume<10 ml (n=89), group 2: volume between 10 and 20 ml (n=59), and group 3: volume>20 ml (n=50). And the shape of the hematoma was classed into regular (round to ellipsoid) with smooth margins (n=76), irregular with frayed margins (n=85), and multilobular (n=37). The slice method, voxelization method, and 3D-Slicer method were adopted to measure the volume of hematoma, respectively, considering the nonclosed models and the models which may contain inaccurate normal information during CT scan. Moreover, the results were compared with the 3D-Slicer method for closed models. Results. There was a significant estimation error (P<0.05) using these three methods to calculate the volume of the closed hematoma model. The estimated hematoma volume was calculated to be 14.2086743±0.900559087 ml, 14.2119130±0.900851812 ml, and 14.2123825±0.900835916 ml using slice method 1, slice method 2, and the voxelization method, respectively, compared to 14.212656±0.900992371 ml using the 3D-Slicer method. The mean estimation error was -0.00398172 ml, -0.00074303 ml, and -0.00027354 ml caused by slice method 1, slice method 2, and voxelization method, respectively. There was a significant estimation error (P<0.05), applying these three methods to calculate the volume of the nonclosed hematoma model. The estimated hematoma volume was calculated to be 14.1928246±0.902210314 ml using the 3D-Slicer method. The mean estimation error was calculated to be -0.00402121 ml, -0.00078237 ml, -0.00031288 ml, and -0.01983136 ml using slice method 1, slice method 2, voxelization method, and 3D-Slicer method, respectively. Conclusions. The 3D-Slicer software method is considered as a stable and capable method of high precision for the calculation of a closed hematoma model with correct normal direction, while it would be inappropriate for the nonclosed model nor the model with incorrect normal direction. The slice method and voxelization method can be the supplement and improvement of the 3D-Slicer software method, for the purpose of achieving precision medicine.

2009 ◽  
Vol 50 (3) ◽  
pp. 306-311 ◽  
Author(s):  
Chih-Wei Wang ◽  
Chun-Jung Juan ◽  
Yi-Jui Liu ◽  
Hsian-He Hsu ◽  
Hua-Shan Liu ◽  
...  

Background: Although the ABC/2 formula has been widely used to estimate the volume of intracerebral hematoma (ICH), the formula tends to overestimate hematoma volume. The volume-related imprecision of the ABC/2 formula has not been documented quantitatively. Purpose: To investigate the volume-dependent overestimation of the ABC/2 formula by comparing it with computer-assisted volumetric analysis (CAVA). Material and Methods: Forty patients who had suffered spontaneous ICH and who had undergone non-enhanced brain computed tomography scans were enrolled in this study. The ICH volume was estimated based on the ABC/2 formula and also calculated by CAVA. Based on the ICH volume calculated by the CAVA method, the patients were divided into three groups: group 1 consisted of 17 patients with an ICH volume of less than 20 ml; group 2 comprised 13 patients with an ICH volume of 20 to 40 ml; and group 3 was composed of 10 patients with an ICH volume larger than 40 ml. Results: The mean estimated hematoma volume was 43.6 ml when using the ABC/2 formula, compared with 33.8 ml when using the CAVA method. The mean estimated difference was 1.3 ml, 4.4 ml, and 31.4 ml for groups 1, 2, and 3, respectively, corresponding to an estimation error of 9.9%, 16.7%, and 37.1% by the ABC/2 formula ( P<0.05). Conclusion: The ABC/2 formula significantly overestimates the volume of ICH. A positive association between the estimation error and the volume of ICH is demonstrated.


2018 ◽  
Vol 10 (9) ◽  
pp. 209
Author(s):  
Denison Esequiel Schabarum ◽  
Alberto Cargnelutti Filho ◽  
Cláudia Marques de Bem ◽  
Giovani Facco ◽  
Jéssica Andiara Kleinpaul ◽  
...  

Sunn hemp (Crotalaria juncea L.) is an annual cycle legume with high potential for biological nitrogen fixation, being widely used in crop rotation for biomass formation and control of nematodes. The objectives of this study were to determine the sample size for the mean estimation of productive traits of sunn hemp and verify the sample size variability between traits and sowing dates. Two uniformity trials were performed in the agricultural year 2014/2015, with sowing in October (trial 1) and December (trial 2). At the crop flowering stage, 300 plants of each trial were harvested and fresh and dry matter of leaves, stem, root, aerial part, and total weight were evaluated. The normality and randomness tests were performed for each trait and the sample size was calculated for the semi-amplitudes of the confidence interval (estimation errors) of 2, 4, 6, 8, 10, 12, 14, 16, 18 and 20% of the mean estimate. There is sample size variability between productive traits and between sowing dates. The assessment of at least 101 plants is required for mean estimation of productive traits with maximum estimation error of 20% of the mean and 95% confidence level.


2021 ◽  
pp. 112067212110177
Author(s):  
Ayse Gul Kocak Altintas ◽  
Cagri Ilhan

Purpose: To compare the phaco time parameters including ultrasound time (UST), effective phaco time (EPT), and average phaco power (APP) in eyes with pseudoexfoliation glaucoma (PEG) and had or had not glaucoma filtration surgery. Methods: In this retrospective comparative study, Group 1 was constructed with 84 PEG patients who had not operated previously, and Group 2 was constructed with 49 PEG patients who had glaucoma filtration surgery. The mean values of UST, EPT, and APP were compared. The preoperative clinical characteristics and surgical manipulations were also compared. Results: The mean ages and male-to-female ratios of the groups were similar ( p > 0.05, for both). There was no difference in the preoperative clinical characteristics, including biometric values between the groups ( p > 0.05, for all). Some surgical manipulations, including pupillary stretching ( p = 0.004), pupillary membrane peeling ( p = 0.021), iris hook using ( p = 0.041), and capsular tension ring implantation ( p = 0.041), were significantly performed more commonly in Group 2. Although the mean UST and EPT values were similar ( p > 0.05, for both), the mean APP value was significantly lower in Group 2 ( p = 0.011). Conclusion: The lower APP parameter was observed in PEG patients having had glaucoma filtration surgery. Needing more surgical manipulation to overcome poor pupillary dilation and weak zonular instability can be a reason for this result.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J Proff ◽  
B Merkely ◽  
R Papp ◽  
C Lenz ◽  
P.J Nordbeck ◽  
...  

Abstract Background The prevalence of chronotropic incompetence (CI) in heart failure (HF) population is high and negatively impacts prognosis. In HF patients with an implanted cardiac resynchronisation therapy (CRT) device and severe CI, the effect of rate adaptive pacing on patient outcomes is unclear. Closed loop stimulation (CLS) based on cardiac impedance measurement may be an optimal method of heart rate adaptation according to metabolic need in HF patients with severe CI. Purpose This is the first study evaluating the effect of CLS on the established prognostic parameters assessed by the cardio-pulmonary exercise (CPX) testing and on quality of life (QoL) of the patients. Methods A randomised, controlled, double-blind and crossover pilot study has been performed in CRT patients with severe CI defined as the inability to achieve 70% of the age-predicted maximum heart rate (APMHR). After baseline assessment, patients were randomised to either DDD-CLS pacing (group 1) or DDD pacing at 40 bpm (group 2) for a 1-month period, followed by crossover for another month. At baseline and at 1- and 2-month follow-ups, a CPX was performed and QoL was assessed using the EQ-5D-5L questionnaire. The main endpoints were the effect of CLS on ventilatory efficiency (VE) slope (evaluated by an independent CPX expert), the responder rate defined as an improvement (decrease) of the VE slope by at least 5%, percentage of maximal predicted heart rate reserve (HRR) achieved, and QoL. Results Of the 36 patients enrolled in the study, 20 fulfilled the criterion for severe CI and entered the study follow-up (mean age 68.9±7.4 years, 70% men, LVEF=41.8±9.3%, 40%/60% NYHA class II/III). Full baseline and follow-up datasets were obtained in 17 patients. The mean VE slope and HRR at baseline were 34.4±4.4 and 49.6±23.8%, respectively, in group 1 (n=7) and 34.5±12.2 and 54.2±16.1% in group 2 (n=10). After completing the 2-month CPX, the mean difference between DDD-CLS and DDD-40 modes was −2.4±8.3 (group 1) and −1.2±3.5 (group 2) for VE slope, and 17.1±15.5% (group 1) and 8.7±18.8% (group 2) for HRR. Altogether, VE slope improved by −1.8±2.95 (p=0.31) in DDD-CLS versus DDD-40, and HRR improved by 12.9±8.8% (p=0.01). The VE slope decreased by ≥5% in 47% of patients (“responders to CLS”). The mean difference in the QoL between DDD-CLS and DDD-40 was 0.16±0.25 in group 1 and −0.01±0.05 in group 2, resulting in an overall increase by 0.08±0.08 in the DDD-CLS mode (p=0.13). Conclusion First results of the evaluation of the effectiveness of CLS in CRT patients with severe CI revealed that CLS generated an overall positive effect on well-established surrogate parameters for prognosis. About one half of the patients showed CLS response in terms of improved VE slope. In addition, CLS improved quality of life. Further clinical research is needed to identify predictors that can increase the responder rate and to confirm improvement in clinical outcomes. Funding Acknowledgement Type of funding source: Private company. Main funding source(s): Biotronik SE & Co. KG


Animals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 408
Author(s):  
Francesca Del Baldo ◽  
Alessia Diana ◽  
Claudia Canton ◽  
Nikolina Linta ◽  
Roberto Chiocchetti ◽  
...  

A flash glucose monitoring system (FGMS) has been validated for use in diabetic dogs. However, it is unknown whether skin thickness affects FGMS measurements. The aim of this study was to evaluate whether FGMS accuracy is affected by skin thickness. Fourteen client-owned diabetic dogs on insulin treatment were prospectively enrolled in the study. The dogs were divided into two groups according to their ultrasound-measured skin thickness: dogs with skin thickness < 5 mm (Group 1) and dogs with skin thickness > 5 mm (Group 2). On days 1, 7 and 14, glucose curves were obtained simultaneously using the FGMS and a validated portable blood glucose meter. Paired measurements were used to calculate the mean bias and to determine accuracy according to ISO 15197:2013 criteria. The mean bias was significantly inversely correlated (p = 0.02; r = −0.6) with the mean skin thickness. Clinical accuracy was observed only in Group 2, with 99% of the results in zone A + B of the Parkes consensus error grid analysis. In conclusion, skin thickness seems to affect FGMS measurements, and the device is accurate in dogs with thicker skin (>5 mm); in dogs with thin skin (<5 mm), the clinical accuracy is low, and the results should be interpreted with caution.


Angiology ◽  
2021 ◽  
pp. 000331972199141
Author(s):  
Arafat Yildirim ◽  
Mehmet Kucukosmanoglu ◽  
Fethi Yavuz ◽  
Nermin Yildiz Koyunsever ◽  
Yusuf Cekici ◽  
...  

Many parameters included in the Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) and CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke, vascular disease, age 65-74 years, sex category) scores also predict coronary artery disease (CAD). We modified the ATRIA score (ATRIA-HSV) by adding hyperlipidemia, smoking, and vascular disease and also male sex instead of female. We evaluated whether the CHA2DS2-VASc, CHA2DS2-VASc-HS, ATRIA, and ATRIA-HSV scores predict severe CAD. Consecutive patients with coronary angiography were prospectively included. A ≥50% stenosis in ≥1epicardial coronary artery (CA) was defined as severe CAD. Patient with normal CA (n = 210) were defined as group 1, with <50% CA stenosis (n = 178) as group 2, and with ≥50% stenosis (n = 297) as group 3. The mean ATRIA, ATRIA-HSV, CHA2DS2-VASc, and CHA2DS2VASc-HS scores increased from group 1 to group 3. A correlation was found between the Synergy between PCI with Taxus and Cardiac Surgery score and ATRIA ( r = 0.570), ATRIA-HSV ( r = 0.614), CHA2DS2-VASc ( r = 0.428), and CHA2DS2-VASc-HS ( r = 0.500) scores ( Ps < .005). Pairwise comparisons of receiver operating characteristics curves showed that ATRIA-HSV (>3 area under curve [AUC]: 0.874) and ATRIA (>3, AUC: 0.854) have a better performance than CHA2DS2-VASc (>1, AUC: 0.746) and CHA2DS2-VASc-HS (>2, AUC: 0.769). In conclusion, the ATRIA and ATRIA-HSV scores are simple and may be useful to predict severe CAD.


2020 ◽  
pp. 105566562098023
Author(s):  
Ashwina S. Banari ◽  
Sanjeev Datana ◽  
Shiv Shankar Agarwal ◽  
Sujit Kumar Bhandari

Objectives: To compare nasal and upper airway dimensions in patients with cleft lip and palate (CLP) who underwent nasoalveolar molding (NAM) with those without NAM during infancy using acoustic pharyngometry and rhinometry. Materials and Methods: Eccovision acoustic pharyngometry and rhinometry (Sleep Group Solutions) was used for assessment of mean area and volume of nasal and upper airway in patients with complete unilateral CLP (age range 16-21 years) treated with NAM (group 1, n = 19) versus without NAM (group 2, n = 22). Results: The mean nasal cross-sectional areas and volume were higher in group 1 compared to group 2 on both cleft ( P value <.001) and noncleft side ( P value >.05). The mean area and volume of upper airway were also significantly higher in group 1 compared to group 2 ( P value <.05). Conclusions: Nasoalveolar molding being one of the first interventions in chronology of treatment of patients with CLP, its long-term outcome on nasal and upper airway patency needs to be ascertained. The results of the present study show that the patients with CLP who have undergone NAM during infancy have better improvement in nasal and upper airway patency compared with those who had not undergone NAM procedure. The basic advantages of being noninvasive, nonionizing and providing dynamic assessment of nasal and upper airway patency make acoustic pharyngometry and rhinometry a diagnostic tool of choice to be used in patients with CLP.


2019 ◽  
Vol 1 (1) ◽  
pp. 7-10
Author(s):  
Gaurav Singh ◽  
Madan Mishra ◽  
Amit Gaur ◽  
Dhritiman Pathak

Background: Fractures of the mandible can be studied and described in anatomic terms, functional considerations, treatment strategies, and outcome measures. The performance of any fixation system depends on multiple factors including plate adaptation, screw placement, bone quality, drilling conditions, and postoperative patient compliance. Bite force assesses masticatory muscle function under clinical and experimental conditions. Method: 30 patients with isolated, noncomminuted mandibular fractures were randomly divided into two equal groups. Group 1 patients were treated using 3-dimensional locking miniplates and group 2 patients were treated with standard miniplates. The bite forces were recorded at definite time intervals: preoperatively, and second week, sixth week, third month, and sixth month postoperatively. Result: At 6 weeks postoperative, 3 month postoperative, and 6 month postoperative, the mean bite force was found to be significantly higher among group 1 patients as compared to those in group 2 in all the sites. While at 2 week postoperative, the mean bite force was found to be significantly higher in Group 2 as compared to Group 1 at incisor region. Conclusion: The overall results of the present study show better performance in bite force for the 3-dimensional locking miniplate when compared with standard miniplates.


2021 ◽  
Vol 9 (4) ◽  
pp. 232596712110024
Author(s):  
Koray Şahin ◽  
Fatih Şentürk ◽  
Mehmet Ersin ◽  
Ufuk Arzu ◽  
Mechmet Chodza ◽  
...  

Background: Knot-tying suture-bridge (SB) rotator cuff repair may compromise the vascularity of the repaired tendon, causing tendon strangulation and medial repair failure. The knotless SB repair technique has been proposed to overcome this possibility and decrease retear rates. Purpose: To compare clinical and structural outcomes and retear patterns between the knot-tying and knotless SB techniques. We hypothesized that the knotless technique would result in lower retear rates owing to the preservation of intratendinous vascularity. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A total of 104 patients with full-thickness rotator cuff tears were randomly and prospectively allocated to undergo knot-tying (group 1) or knotless (group 2) SB repair. Clinical outcome measures included range of motion, the visual analog scale (VAS) for pain, and the Constant score for function. Repair integrity was evaluated on magnetic resonance imaging scans using the Sugaya classification. Retears were also classified according to their pattern as type 1 (lateral) or type 2 (medial). Results: Overall, 88 patients (group 1: n = 42 [mean ± SD age, 54.3 ± 9.8 years]; group 2: n = 46 [mean ± SD age, 55.8 ± 8.2 years]) were included in the final analysis. The mean ± SD follow-up period was 25.4 ± 8.3 and 23.3 ± 7.2 months for groups 1 and 2, respectively. From preoperatively to postoperatively, the mean VAS pain score improved significantly in both groups (group 1: from 7.4 ± 1.7 to 1.0 ± 1.7; group 2: from 7.1 ± 1.9 to 1.3 ± 2.0; P < .0001 for both), as did the mean ± SD Constant score (group 1: from 51.7 ± 13.4 to 86.0 ± 11.5; group 2: from 49.4 ± 18.4 to 87.2 ± 14.8; P < .0001 for both). There was no significant difference between the groups for the postoperative VAS or Constant score. The retear rate was not significantly different between the groups (19.0% [8/42] in group 1 and 28.3% [13/46] in group 2; P > .05). There was a significant difference in the type 2 failure rate (75.0% [6/8] in group 1 and 23.1% [3/13] in group 2; P = .03). Conclusion: Both techniques showed excellent improvement and comparable clinical outcomes, and there was no significant difference in retear rates. Consistent with previously published data, the type 2 failure rate was significantly higher with the knot-tying technique. Registration: NCT03982108 ( ClinicalTrials.gov identifier).


Sign in / Sign up

Export Citation Format

Share Document