scholarly journals Repeatability and Reproducibility of SMTube Measurement in Dry Eye Disease Patients

2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Yiran Hao ◽  
Lei Tian ◽  
Kai Cao ◽  
Ying Jie

Purpose. To evaluate the intraobserver repeatability and interobserver reproducibility of Strip Meniscometry Tube (SMTube) and determine the correlations among the SMTube measurements and other ocular examinations in dry eye disease (DED) patients. Methods. The study recruited 73 eyes of 49 DED patients. Every subject was subjected to the following five measurements sequentially: the Ocular Surface Disease Index (OSDI) questionnaire, Tear Meniscus Height (TMH) assessment, SMTube measurements, tear film breakup time (BUT) examination, and Schirmer I test (SIT). The repeatability and reproducibility of the measurements were assessed by the intraclass correlation coefficient (ICC) and the Bland–Altman analysis, and the correlations were evaluated by the Spearman rank-order correlation. Results. The repeatability and reproducibility of the SMTube measurements were good in DED patients. The ICCs between the repeatability and reproducibility of the SMTube measurements were 0.789 and 0.741, respectively, and the Bland–Altman 95% limits of the repeatability and the reproducibility were −1.726 to 1.658 and −0.967 to 1.474, respectively (all P < 0.01 ). The SMTube measurements had correlations with TMH, BUT, and SIT. The Spearman rank correlation coefficients between SMTube and TMH; SMTube and Schirmer I test; and SMTube and BUT were 0.632, 0.617, and 0.653, respectively (all P < 0.01 ). Conclusions. The measurements of the SMTube may provide a novel, swift, noninvasive, and convenient approach to screen and diagnose DED with acceptable repeatability and reproducibility and specific correlations with TMH, BUT, and SIT.

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Yujie Mou ◽  
Huan Xiang ◽  
Lin Lin ◽  
Kelan Yuan ◽  
Xin Wang ◽  
...  

AbstractThis study aims to investigate the reliability and efficacy of maximum fluorescein tear break-up time (FTBUTmax) in diagnosing dry eye disease (DED). 147 participants were enrolled in this study. Ocular symptoms were assessed by Ocular Surface Disease Index (OSDI). The fluorescein tear break-up time (FTBUT) examination, corneal fluorescein staining (CFS), and Schirmer I test were performed on both eyes. Each participant underwent 3 consecutive FTBUT tests, and five types of FTBUT values including FTBUTmax, the minimum FTBUT (FTBUTmin), the first FTBUT (FTBUT1), the average of three FTBUTs (FTBUT123) and the average of the first and second FTBUT (FTBUT12) were recorded. FTBUTmax was larger than the other FTBUT values, but no differences were found among the values of FTBUT1, FTBUT123, FTBUT12 and FTBUTmin. In the ROC analysis, FTBUTmax had the largest or the second largest area under the ROC (AUROC) in all three DED diagnostic criteria, while FTBUTmin had the least AUROC of them. ROC efficacy of FTBUTmax was significantly higher than that of FTBUT123, FTBUT12, FTBUT1 and FTBUTmin in the OSDI criteria and higher than that of FTBUT1 and FTBUTmin in Schirmer I test and CFS tests. FTBUTmax has a close correlation with OSDI, Schirmer I test and CFS, and is an effective tool for the DED diagnosis.


2021 ◽  
Author(s):  
Yujie Mou ◽  
Huan Xiang ◽  
Lin Lin ◽  
Kelan Yuan ◽  
Xin Wang ◽  
...  

Abstract This study aims to investigate the reliability and efficacy of maximum fluorescein tear break-up time (FTBUTmax) in diagnosing dry eye disease (DED). 147 participants were enrolled in this study. Ocular symptoms were assessed by Ocular Surface Disease Index (OSDI). The fluorescein tear break-up time (FTBUT) examination, corneal fluorescein staining (CFS), and Schirmer I test were performed on both eyes. Each participant underwent 3 consecutive FTBUT tests, and five types of FTBUT values including FTBUTmax, the minimum FTBUT (FTBUTmin), the first FTBUT (FTBUT1), the average of three FTBUTs (FTBUT123) and the average of the first and second FTBUT (FTBUT12) were recorded. FTBUTmax was larger than the other FTBUT values, but no differences were found among the values of FTBUT1, FTBUT123, FTBUT12 and FTBUTmin. In the ROC analysis, FTBUTmax had the largest or the second largest area under the ROC (AUROC) in all three DED diagnostic criteria, while FTBUTmin had the least AUROC of them. ROC efficacy of FTBUTmax was significantly higher than that of FTBUT123, FTBUT12, FTBUT1 and FTBUTmin in the OSDI criteria and higher than that of FTBUT1 and FTBUTmin in Schirmer and CFS tests. FTBUTmax has a close correlation with OSDI, Schirmer I test and CFS, and is an effective tool for the DED diagnosis.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Lei Tian ◽  
Jing-hao Qu ◽  
Xiao-yu zhang ◽  
Xu-guang Sun

Purpose. To determine the intraexaminer repeatability and interexaminer reproducibility of tear meniscus height (TMH) and noninvasive Keratograph tear breakup time (NIKBUT) measurements obtained with the Keratograph 5M (K5M) in a sample of healthy and dry eye populations.Methods. Forty-two patients with dry eye disease (DED group) and 42 healthy subjects (healthy group) were recruited in this prospective study. In all subjects, each eye received 3 consecutive measurements using the K5M for the TMH and NIKBUTs (NIKBUT-first and NIKBUT-average). And then a different examiner repeated the measurements. The repeatability and reproducibility of measurements were assessed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC).Results. The repeatability and reproducibility of TMH and NIKBUTs were good in both DED and healthy groups (CV% ≤ 26.1% and ICC ≥ 0.75 for all measurements). Patients with DED showed better intraexaminer repeatability for NIKBUTs, but worse for TMH than healthy subjects. Average TMH, NIKBUT-first, and NIKBUT-average were significantly lower in DED group than in healthy group (allPvalues < 0.05).Conclusions. Measurements of TMH and NIKBUTs obtained with the K5M may provide a simple, noninvasive screening test for dry eye with acceptable repeatability and reproducibility. The NIKBUTs were more reliable, but TMH was less reliable in patients with DED.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Miraf Sahlu ◽  
Abeba T. Giorgis

Abstract Background Dry eye disease is a multifactorial disease; causing various ocular symptoms with potential damage to the ocular surface. Applying hypotensive eye drops are presumed to initiate or exacerbate existing dry eye disease. The purpose of this study was to determine the frequency of signs and symptoms and severity of dry eye disease among glaucoma patients on topical hypotensive medications and controls. Methods A cross-sectional comparative study, involving 320 glaucoma patients and controls. Ocular Surface Disease Index (OSDI) symptoms score and Schirmer, tear breakup time and corneal staining tests were used to assess dry eye disease. Data was analyzed using SPSS version 24 software; p-value less than 0.05 was considered as statistically significant. Results Among the 160 study glaucoma patients, the mean duration of topical hypotensive medication use was 5.2 ± 5.21 years (range, 4 months - 32 years). Mild to severe level of OSDI score was found in 122 (76%) glaucoma patients and in 137 (86%) controls (p = 0.033). Mild to sever abnormal clinical tests in the glaucoma patients and control, respectively, were 106 (66%) vs 80 (50%) corneal staining (p = 0.045), 79 (49%) vs 72 (45%) TBUT (p = 0.021), and 91 (57%) vs 83 (52%) Schirmer test (p = 0.242). Test results at the level of sever: 2 (1%) vs 0 (0%) corneal staining, 50 (31%) vs 39 (24%) TBUT and 65 (41%) vs 60 (38%) Schirmer test in the glaucoma patents and controls, respectively. Corneal staining and TBUT had correlation with the number of drugs (p = 0.004 and 0.031, respectively), and more relationship of the two tests with total number of drops applied per day (p = 0.01 and p <  0.001, respectively). Patients on pilocarpine and timolol had more corneal staining and lower TBUT [(p = 0.011 and p <  0.001) and (p = 0.04 and 0.012), respectively]. Conclusions The study has identified glaucoma patients to be more affected by dry eye disease than non-glaucoma patients, and presence of significantly lower TBUT and higher corneal staining in the glaucoma patients on multidrops and multidose per day. We recommend consideration of evaluation and management of DED for glaucoma patients on multidrops and multidose hypotensive medications.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Chigozie I. Echieh ◽  
Bassey A. Etim ◽  
Chidiebere Peter Echieh ◽  
Taiwo Oyeniyi ◽  
Jeff Ajewole

Abstract Background Occupational predisposition to dry eye disease is known. Simultaneous exposure to multiple factors may pose more risk. Street sweepers are exposed to sunlight in addition to dust which all sweepers are exposed to. Tropical climate predisposes to significant exposure to sunlight. Combined exposure to dust and sunlight may lead to a synergy of factors. This study aims to assess the prevalence of dry eye disease (DED) amongst Street sweepers and Office cleaners in Calabar metropolis. Methods A cross-sectional study was conducted among street sweepers and office cleaners. A systematic random sampling and multi-stage sampling method were used to select street sweepers (n = 115) and office cleaners (n = 115) respectively for the study. A pretested semi-structured interviewer-administered questionnaire was used to obtain information after which the respondents had an ophthalmic examination. An assessment of DED was done with Ocular Surface Disease Index (OSDI) questionnaire, Schirmer’s test, and tear break up time (TBUT). OSDI scores of 33 and above; Schirmer’s test readings of < 10 mm wetting in 5 min and a TBUT of less than 10s in either eye were considered as positive dry eye disease. Results The majority of respondents were females 215(93.5%) compared to males 15 (6.5%). The overall mean age of respondents was 40.96 ± 9.8 years. The average OSDI score, Schirmer’s test as well as TBUT among participants was 26.4 ± 16.0, 16.44 ± 9.52 mm, and 12.38 ± 4.53 s respectively. The prevalence of DED among Street sweepers was 35.7% compared to 20% among office cleaners using the OSDI questionnaire (p = 0.352). The prevalence of DED among street sweepers was 32.2% compared to 30.4% among Office cleaners using the Schirmer’s test. (p = 0.73) The TBUT reported a prevalence of 38.3% of DED among Street sweepers compared to 32.2% in office cleaners. (p = 0.48) Overall; the prevalence of dry eye disease among Street sweepers and office cleaners using OSDI score, Schirmers test, as well as TBUT were not statistically significant (> 0.05) Street Sweepers had higher odds of developing dry eye disease compared to office cleaners (OR = 2.085; C.I. =1.106–3.929; p = 0.02). Negative correlation coefficient was observed between TBUT and OSDI (rs = − 0.102; p = 0.125). This was not statistically significant. Conclusion Street sweepers had a higher prevalence of dry eye disease compared to office cleaners due to a higher risk of increased exposure to environmental factors such as dust, smoke, and sunlight. This effect is possibly due to a synergy of factors. Studies on dose-response are warranted.


2019 ◽  
Vol 2019 ◽  
pp. 1-9 ◽  
Author(s):  
Zsolt Barta ◽  
Levente Czompa ◽  
Aniko Rentka ◽  
Eva Zold ◽  
Judit Remenyik ◽  
...  

Aim. To evaluate tear film parameters and relationship of objective clinical signs and subjective symptoms of dry eye disease (DED) in inflammatory bowel disease (IBD) subgroups. Methods. 39 patients with Crohn’s disease (CD), 26 patients with ulcerative colitis (UC), and 39 control persons with no ocular symptoms or surface disorders were included in this prospective, case-control, and cross-sectional study. The ocular surface disease index (OSDI) questionnaire was applied to evaluate dry eye symptoms, and objective tests of DED were performed on both eyes of each subject. Results. The average of OSDI scores was 30.59 (±16.68) in CD patients, 24.67 (±23.48) in UC patients, and 11.19 (±5.8) in controls. Except for tear film breakup time (tBUT) and Schirmer-I values other objective parameters were better in UC patients, than in CD patients. CD patients rather than UC patients tend to develop DED. This was associated with immunosuppressant and TNF-α inhibitor use. Conclusions. Clinicians must be aware of the spectrum of DED involvement in IBD and suggest using artificial tears in order to decrease severity of ocular complications.


2020 ◽  
Vol 9 (11) ◽  
pp. 3791
Author(s):  
Gerhard Garhöfer ◽  
Valentin Aranha Dos Santos ◽  
Hannes Stegmann ◽  
Doreen Schmidl ◽  
Narine Adzhemian ◽  
...  

Purpose: To determine the association between tear film thickness (TFT) as measured with ultra-high resolution optical coherence tomography (UHR-OCT) and signs and symptoms of dry eye disease (DED). Methods: A total of 450 eyes from 225 patients with DED from six different randomized clinical trials were included in this pooled analysis. In all subjects, TFT was measured with a custom-built UHR-OCT system. Symptoms of DED were quantified using a standardized Ocular Surface Disease Index (OSD)I questionnaire and clinical signs including tear film break up time (TFBUT) and Schirmer I test were assessed. Associations of the average TFT with OSDI, TFBUT, and Schirmer I test were calculated using a linear regression analysis. Results: The average TFT of the included sample (mean age, 45.0 ± 13.3 years; 65% female) was 4.2 ± 0.5 µm and the OSDI 36.2 ± 10.4. A significant negative correlation was found between TFT and OSDI (r = −0.36 to −0.31; p < 0.001). Tear break up time and Schirmer I test were not correlated with OSDI. Significant albeit weak correlations were found between TFT and TFBUT (r = 0.17 to 0.25; p < 0.01) as well as Schirmer I (r = 0.36 to 0.37; p < 0.001). Subgroup analysis revealed that the correlation was stronger in the subjects with abnormal Schirmer I (<15 mm; r = 0.50 to 0.54; p < 0.001). Conclusions: The present study demonstrates an objective measurement of TFT using a novel OCT approach for DED that correlates with symptoms and signs of DED. Our data are consistent with the idea that TFT represents the aqueous-deficient component of DED.


Author(s):  
Maneesha Sethi ◽  
Amarjeet Singh Bali ◽  
P. Sadhotra

Background: Dry eye is a multifactorial disease particularly prevalent in Asia for which there are several treatments. Among anti-inflammatory treatment, cyclosporine 0.05% is preferred therapy. Our study evaluated effects of cyclosporine 0.05% ophthalmic solution on the diagnostic tools of dry eye.Material & Methods: A prospective study was carried out in ophthalmological outpatient department of ASCOMS and Hospital. Total 60 patients of dry eye disease who fulfilled the inclusion criteria were treated with cyclosporine 0.05% ophthalmic solution twice a day. The diagnostic parameters of dry eye were assessed at baseline, at month 1 and 3. Patients underwent Ocular Surface Disease Index (OSDI) score, Schirmer’s test, Tear film break up time (TBUT) .Results: After three months, mean OSDI score was significantly improved (p < 0.001). There was significant improvement in mean Schirmer score (p < 0.001). Baseline TBUT also increased significantly (p < 0.001). Conclusion: Cyclosporine 0.05% ophthalmic solution has significant effect on diagnostic parameters of dry eye disease.  


2019 ◽  
Author(s):  
José-María Sánchez-González ◽  
Concepción De-Hita-Cantalejo ◽  
María Carmen Sánchez-González

Abstract Background: To study the effect of uncrosslinked and crosslinked hyaluronic acid combined with other artificial tear components in patients with dry eye caused by moderate meibomian gland dysfunction.Method: Prospective, single-blind, contralateral eye study. Fifty eyes were analyzed (25 patients). Eye selection for each tear type was random, and the eye drop formulations Aquoral Forte® (artificial tear A) and Aquoral Lipo® (artificial tear B) were used. The determined dosing schedule was three times a day for six weeks, and the study participants underwent a clinical examination before and 45 days after lubricant treatment. The Schirmer test, tear breakup time (TBUT) test, and Ocular Surface Disease Index (OSDI) questionnaire were applied before and after instillation period with both types of artificial tears. Results: On the Schirmer test, a significant improvement was obtained with both tear A (p < 0.01) and tear B (p < 0.01). On the TBUT test, a significant improvement was obtained with tear A (p < 0.01) and tear B (p < 0.01). The OSDI score significantly decreased after instillation period with both artificial tear types (p < 0.01). Conclusion: Uncrosslinked hyaluronic acid combined with other components, such as tamarind seed polysaccharide, and crosslinked hyaluronic acid combined with liposomes and crocin are effective for management symptoms of dry eye disease.