scholarly journals The Analysis about Compressed Sensing Reconstruction Algorithm Based on Machine Learning Applied in Interference Multispectral Images

2021 ◽  
Vol 2021 ◽  
pp. 1-6
Author(s):  
Chang Han

Interferometric multispectral images contain rich information, so they are widely used in aviation, military, and environmental monitoring. However, the abundant information also leads to the disadvantages that longer time and more physical resources are needed in signal compression and reconstruction. In order to make up for the shortcomings of traditional compression and reconstruction algorithms, the stacked convolution denoising autoencoder (SCDA) reconstruction algorithm for interference multispectral images is proposed in this paper. And, the experimental code based on the TensorFlow system is built to reconstruct these images. The results show that, compared with D-AMP and ReconNet algorithms, the SCDA algorithm has the advantages of higher reconstruction accuracy and lower time complexity and space complexity. Therefore, the SCDA algorithm proposed in this paper can be applied to interference multispectral images.

2020 ◽  
Vol 6 (12) ◽  
pp. 135
Author(s):  
Marinus J. Lagerwerf ◽  
Daniël M. Pelt ◽  
Willem Jan Palenstijn ◽  
Kees Joost Batenburg

Circular cone-beam (CCB) Computed Tomography (CT) has become an integral part of industrial quality control, materials science and medical imaging. The need to acquire and process each scan in a short time naturally leads to trade-offs between speed and reconstruction quality, creating a need for fast reconstruction algorithms capable of creating accurate reconstructions from limited data. In this paper, we introduce the Neural Network Feldkamp–Davis–Kress (NN-FDK) algorithm. This algorithm adds a machine learning component to the FDK algorithm to improve its reconstruction accuracy while maintaining its computational efficiency. Moreover, the NN-FDK algorithm is designed such that it has low training data requirements and is fast to train. This ensures that the proposed algorithm can be used to improve image quality in high-throughput CT scanning settings, where FDK is currently used to keep pace with the acquisition speed using readily available computational resources. We compare the NN-FDK algorithm to two standard CT reconstruction algorithms and to two popular deep neural networks trained to remove reconstruction artifacts from the 2D slices of an FDK reconstruction. We show that the NN-FDK reconstruction algorithm is substantially faster in computing a reconstruction than all the tested alternative methods except for the standard FDK algorithm and we show it can compute accurate CCB CT reconstructions in cases of high noise, a low number of projection angles or large cone angles. Moreover, we show that the training time of an NN-FDK network is orders of magnitude lower than the considered deep neural networks, with only a slight reduction in reconstruction accuracy.


2021 ◽  
pp. 002029402110197
Author(s):  
Yan Liu ◽  
Wei Tang ◽  
Yiduo Luan

The traditional reconstruction algorithms based on p-norm, limited by their reconstruction model and data processing mode, are prone to reconstruction failure or long reconstruction time. In order to break through the limitations, this paper proposes a reconstruction algorithm based on the temporal neural network (TCN). A new reconstruction model based on TCN is first established, which does not need sparse representation and has large-scale parallel processing. Next, a TCN with a fully connected layer and symmetrical zero-padding operation is designed to meet the reconstruction requirements, including non-causality and length-inconsistency. Moreover, the proposed algorithm is constructed and applied to power quality disturbance (PQD) data. Experimental results show that the proposed algorithm can implement the reconstruction task, demonstrating better reconstruction accuracy and less reconstruction time than OMP, ROMP, CoSaMP, and SP. Therefore, the proposed algorithm is more attractive when dictionary design is complicated, or real-time reconstruction is required.


2021 ◽  
Vol 27 ◽  
pp. 1239-1254
Author(s):  
Hong Anh Thi Nguyen ◽  
Tip Sophea ◽  
Shabbir H. Gheewala ◽  
Rawee Rattanakom ◽  
Thanita Areerob ◽  
...  

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Johan Economou Lundeberg ◽  
Jenny Oddstig ◽  
Ulrika Bitzén ◽  
Elin Trägårdh

Abstract Background Lung cancer is one of the most common cancers in the world. Early detection and correct staging are fundamental for treatment and prognosis. Positron emission tomography with computed tomography (PET/CT) is recommended clinically. Silicon (Si) photomultiplier (PM)-based PET technology and new reconstruction algorithms are hoped to increase the detection of small lesions and enable earlier detection of pathologies including metastatic spread. The aim of this study was to compare the diagnostic performance of a SiPM-based PET/CT (including a new block-sequential regularization expectation maximization (BSREM) reconstruction algorithm) with a conventional PM-based PET/CT including a conventional ordered subset expectation maximization (OSEM) reconstruction algorithm. The focus was patients admitted for 18F-fluorodeoxyglucose (FDG) PET/CT for initial diagnosis and staging of suspected lung cancer. Patients were scanned on both a SiPM-based PET/CT (Discovery MI; GE Healthcare, Milwaukee, MI, USA) and a PM-based PET/CT (Discovery 690; GE Healthcare, Milwaukee, MI, USA). Standardized uptake values (SUV) and image interpretation were compared between the two systems. Image interpretations were further compared with histopathology when available. Results Seventeen patients referred for suspected lung cancer were included in our single injection, dual imaging study. No statically significant differences in SUVmax of suspected malignant primary tumours were found between the two PET/CT systems. SUVmax in suspected malignant intrathoracic lymph nodes was 10% higher on the SiPM-based system (p = 0.026). Good consistency (14/17 cases) between the PET/CT systems were found when comparing simplified TNM staging. The available histology results did not find any obvious differences between the systems. Conclusion In a clinical setting, the new SiPM-based PET/CT system with a new BSREM reconstruction algorithm provided a higher SUVmax for suspected lymph node metastases compared to the PM-based system. However, no improvement in lung cancer detection was seen.


Micromachines ◽  
2021 ◽  
Vol 12 (2) ◽  
pp. 164
Author(s):  
Dongxu Wu ◽  
Fusheng Liang ◽  
Chengwei Kang ◽  
Fengzhou Fang

Optical interferometry plays an important role in the topographical surface measurement and characterization in precision/ultra-precision manufacturing. An appropriate surface reconstruction algorithm is essential in obtaining accurate topography information from the digitized interferograms. However, the performance of a surface reconstruction algorithm in interferometric measurements is influenced by environmental disturbances and system noise. This paper presents a comparative analysis of three algorithms commonly used for coherence envelope detection in vertical scanning interferometry, including the centroid method, fast Fourier transform (FFT), and Hilbert transform (HT). Numerical analysis and experimental studies were carried out to evaluate the performance of different envelope detection algorithms in terms of measurement accuracy, speed, and noise resistance. Step height standards were measured using a developed interferometer and the step profiles were reconstructed by different algorithms. The results show that the centroid method has a higher measurement speed than the FFT and HT methods, but it can only provide acceptable measurement accuracy at a low noise level. The FFT and HT methods outperform the centroid method in terms of noise immunity and measurement accuracy. Even if the FFT and HT methods provide similar measurement accuracy, the HT method has a superior measurement speed compared to the FFT method.


2021 ◽  
Vol 5 (3) ◽  
pp. 1-30
Author(s):  
Gonçalo Jesus ◽  
António Casimiro ◽  
Anabela Oliveira

Sensor platforms used in environmental monitoring applications are often subject to harsh environmental conditions while monitoring complex phenomena. Therefore, designing dependable monitoring systems is challenging given the external disturbances affecting sensor measurements. Even the apparently simple task of outlier detection in sensor data becomes a hard problem, amplified by the difficulty in distinguishing true data errors due to sensor faults from deviations due to natural phenomenon, which look like data errors. Existing solutions for runtime outlier detection typically assume that the physical processes can be accurately modeled, or that outliers consist in large deviations that are easily detected and filtered by appropriate thresholds. Other solutions assume that it is possible to deploy multiple sensors providing redundant data to support voting-based techniques. In this article, we propose a new methodology for dependable runtime detection of outliers in environmental monitoring systems, aiming to increase data quality by treating them. We propose the use of machine learning techniques to model each sensor behavior, exploiting the existence of correlated data provided by other related sensors. Using these models, along with knowledge of processed past measurements, it is possible to obtain accurate estimations of the observed environment parameters and build failure detectors that use these estimations. When a failure is detected, these estimations also allow one to correct the erroneous measurements and hence improve the overall data quality. Our methodology not only allows one to distinguish truly abnormal measurements from deviations due to complex natural phenomena, but also allows the quantification of each measurement quality, which is relevant from a dependability perspective. We apply the methodology to real datasets from a complex aquatic monitoring system, measuring temperature and salinity parameters, through which we illustrate the process for building the machine learning prediction models using a technique based on Artificial Neural Networks, denoted ANNODE ( ANN Outlier Detection ). From this application, we also observe the effectiveness of our ANNODE approach for accurate outlier detection in harsh environments. Then we validate these positive results by comparing ANNODE with state-of-the-art solutions for outlier detection. The results show that ANNODE improves existing solutions regarding accuracy of outlier detection.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Robert Peter Reimer ◽  
Konstantin Klein ◽  
Miriam Rinneburger ◽  
David Zopfs ◽  
Simon Lennartz ◽  
...  

AbstractComputed tomography in suspected urolithiasis provides information about the presence, location and size of stones. Particularly stone size is a key parameter in treatment decision; however, data on impact of reformatation and measurement strategies is sparse. This study aimed to investigate the influence of different image reformatations, slice thicknesses and window settings on stone size measurements. Reference stone sizes of 47 kidney stones representative for clinically encountered compositions were measured manually using a digital caliper (Man-M). Afterwards stones were placed in a 3D-printed, semi-anthropomorphic phantom, and scanned using a low dose protocol (CTDIvol 2 mGy). Images were reconstructed using hybrid-iterative and model-based iterative reconstruction algorithms (HIR, MBIR) with different slice thicknesses. Two independent readers measured largest stone diameter on axial (2 mm and 5 mm) and multiplanar reformatations (based upon 0.67 mm reconstructions) using different window settings (soft-tissue and bone). Statistics were conducted using ANOVA ± correction for multiple comparisons. Overall stone size in CT was underestimated compared to Man-M (8.8 ± 2.9 vs. 7.7 ± 2.7 mm, p < 0.05), yet closely correlated (r = 0.70). Reconstruction algorithm and slice thickness did not significantly impact measurements (p > 0.05), while image reformatations and window settings did (p < 0.05). CT measurements using multiplanar reformatation with a bone window setting showed closest agreement with Man-M (8.7 ± 3.1 vs. 8.8 ± 2.9 mm, p < 0.05, r = 0.83). Manual CT-based stone size measurements are most accurate using multiplanar image reformatation with a bone window setting, while measurements on axial planes with different slice thicknesses underestimate true stone size. Therefore, this procedure is recommended when impacting treatment decision.


2017 ◽  
Vol 2017 ◽  
pp. 1-10
Author(s):  
Hsuan-Ming Huang ◽  
Ing-Tsung Hsiao

Background and Objective. Over the past decade, image quality in low-dose computed tomography has been greatly improved by various compressive sensing- (CS-) based reconstruction methods. However, these methods have some disadvantages including high computational cost and slow convergence rate. Many different speed-up techniques for CS-based reconstruction algorithms have been developed. The purpose of this paper is to propose a fast reconstruction framework that combines a CS-based reconstruction algorithm with several speed-up techniques.Methods. First, total difference minimization (TDM) was implemented using the soft-threshold filtering (STF). Second, we combined TDM-STF with the ordered subsets transmission (OSTR) algorithm for accelerating the convergence. To further speed up the convergence of the proposed method, we applied the power factor and the fast iterative shrinkage thresholding algorithm to OSTR and TDM-STF, respectively.Results. Results obtained from simulation and phantom studies showed that many speed-up techniques could be combined to greatly improve the convergence speed of a CS-based reconstruction algorithm. More importantly, the increased computation time (≤10%) was minor as compared to the acceleration provided by the proposed method.Conclusions. In this paper, we have presented a CS-based reconstruction framework that combines several acceleration techniques. Both simulation and phantom studies provide evidence that the proposed method has the potential to satisfy the requirement of fast image reconstruction in practical CT.


Sign in / Sign up

Export Citation Format

Share Document