scholarly journals Matrix Metalloproteinase Neutrophil Gelatinase-Associated Lipocalin Complex Predicts Atrial Fibrillation Recurrence after Electrical Cardioversion in Obese Patients

2016 ◽  
Vol 7 (1) ◽  
pp. 11-20 ◽  
Author(s):  
Elzbieta Mlodawska ◽  
Anna Tomaszuk-Kazberuk ◽  
Paulina Lopatowska ◽  
Ewa Waszkiewicz ◽  
Hanna Bachorzewska-Gajewska ◽  
...  

Background: There is not much data on matrix metalloproteinase neutrophil gelatinase-associated lipocalin (MMP-NGAL) complex in patients with atrial fibrillation (AF). Aim: The aim of the study was to assess the value of MMP-NGAL complex in predicting AF recurrence after electrical cardioversion. Methods: The serum levels of NGAL, cystatin C, interleukin-6, high-sensitivity C-reactive protein, copeptin, MMP-NGAL complex, matrix metalloproteinase 2, tissue inhibitor of metalloproteinase 1, Von Willebrand factor, B-type natriuretic peptide and the urinary level of NGAL were evaluated before cardioversion. Results: A total of 83 patients with persistent AF were enrolled in the study. Left atrial diameter (LA) ≥4.5 cm was significantly associated with AF recurrence at follow-up (p = 0.009). In selected 39 obese patients, MMP-NGAL complex was associated with AF recurrence (p = 0.03). If the concentration of MMP-NGAL complex increased by 1 ng/ml, the odds of AF recurrence increased by 4% (OR 1.04; CI: 1.00-1.08; p = 0.03). MMP-NGAL complex did not correlate with AF recurrence in patients with a first episode of AF, in patients ≥65 years of age and in patients with a LA ≥4.5 cm or with chronic kidney disease. Conclusions: It is known that the greater the BMI at baseline, the higher the likelihood of progression from paroxysmal to permanent AF. However, European Society of Cardiology (ESC) guidelines do not consider obese patients a population with a low likelihood of success of cardioversion. That is why we need a sensitive marker to predict sinus rhythm maintenance in such a population. We found that MMP-NGAL complex may predict AF recurrence after successful cardioversion in obese patients.

Open Heart ◽  
2020 ◽  
Vol 7 (1) ◽  
pp. e001190 ◽  
Author(s):  
John Molvin ◽  
Amra Jujic ◽  
Olle Melander ◽  
Manan Pareek ◽  
Lennart Råstam ◽  
...  

ObjectiveAtrial fibrillation (AF) is the most common arrhythmia and associated with increased morbidity and mortality. Its increasing prevalence calls for novel biomarkers to identify underlying pathophysiological mechanisms as well as patients at risk.MethodsPlasma samples from 1694 individuals from the Swedish population-based Malmö Preventive Project (mean age 69.5 years; 29.3% female; mean follow-up time 9.7±3.1 years) were analysed with the Olink proximity extension assay CVD III panel consisting of 92 proteins to identify proteins associated with incident AF or atrial flutter, referred to as incident AF. Incident cases of AF (n=278) were retrieved by linkage to the registers. Participants were followed until the first episode of AF or until censoring by death or emigration. Bonferroni-corrected multivariable Cox regression models adjusted for known risk factors were used to explore possible associations of the 92 proteins and incidence of AF.ResultsMultivariable Cox regression analyses of 11 proteins associated with incident AF (mean follow-up time 9.7±3.1 years) after Bonferroni correction confirmed N-terminal pro-B-type natriuretic peptide (HR per 1 SD increment (95% CI) 1.80 (1.58 to 2.04); p=1.2×10−19) as risk marker of incident AF. Further, matrix metalloproteinase-2 (1.22 (1.07 to 1.39); p=0.002) and osteopontin (1.27 (1.12 to 1.44); p=2.7×10−4) were associated with incident AF at follow-up independently of traditional risk markers and NT-proBNP.ConclusionIn a general Swedish population, we confirmed the well-known association of NT-proBNP with incident AF and also identified matrix metalloproteinase-2 and osteopontin as novel risk markers for incident AF, independently of traditional risk factors and NT-proBNP.


Cancer ◽  
1998 ◽  
Vol 82 (7) ◽  
pp. 1359-1366 ◽  
Author(s):  
Hiro-omi Kanayama ◽  
Kin-ya Yokota ◽  
Yasushi Kurokawa ◽  
Yoshihide Murakami ◽  
Masaaki Nishitani ◽  
...  

2016 ◽  
Vol 36 (1) ◽  
pp. 16-25 ◽  
Author(s):  
Yeoungjee Cho ◽  
David W. Johnson ◽  
David A. Vesey ◽  
Carmel M. Hawley ◽  
Elaine M. Pascoe ◽  
...  

♦ Background Peritoneal dialysis (PD) patients develop progressive and cumulative peritoneal injury with longer time spent on PD. The present study aimed to a) describe the trend of peritoneal injury biomarkers, matrix metalloproteinase-2 (MMP-2) and tissue inhibitor of metalloproteinase-1 (TIMP-1), in incident PD patients, b) to explore the capacity of dialysate MMP-2 to predict peritoneal solute transport rate (PSTR) and peritonitis, and c) to evaluate the influence of neutral pH, low glucose degradation product (GDP) PD solution on these outcomes. ♦ Methods The study included 178 participants from the balANZ trial who had at least 1 stored dialysate sample. Changes in PSTR and peritonitis were primary outcome measures, and the utility of MMP-2 in predicting these outcomes was analyzed using multilevel linear regression and multilevel Poisson regression, respectively. ♦Results Significant linear increases in dialysate MMP-2 and TIMP-1 concentrations were observed ( p < 0.001), but neither was affected by the type of PD solutions received (MMP-2: p = 0.07; TIMP-1: p = 0.63). An increase in PSTR from baseline was associated with higher levels of MMP-2 ( p = 0.02), and the use of standard solutions over longer PD duration ( p = 0.001). The risk of peritonitis was independently predicted by higher dialysate MMP-2 levels (incidence rate ratio [IRR] per ng/mL 1.01, 95% confidence interval [CI] 1.005 – 1.02, p = 0.002) and use of standard solutions (Biocompatible solution: IRR 0.45, 95% CI 0.24 – 0.85, p = 0.01). ♦ Conclusion Dialysate MMP-2 and TIMP-1 concentrations increased with longer PD duration. Higher MMP-2 levels were associated with faster PSTR and future peritonitis risk. Administration of biocompatible solutions exerted no significant effect on dialysate levels of MMP-2 or TIMP-1, but did counteract the increase in PSTR and the risk of peritonitis associated with the use of standard PD solutions. This is the first longitudinal study to examine the clinical utility of MMP-2 as a predictor of patient-level outcomes.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
T J Bunch ◽  
Heidi T May ◽  
Tami L Bair ◽  
Victoria Jacobs ◽  
Brian G Crandall ◽  
...  

Introduction: Catheter ablation of atrial fibrillation (AF) is an established therapeutic rhythm approach in symptomatic patients. Obesity is a dominant driver of AF recurrence after ablation. Weight reduction strategies lower general AF burden and as such may be critical to long-term success rates after ablation. Hypothesis: Long-term outcomes after AF ablation will be better in obese patients with sustained weight loss. Methods: All patients that underwent an index ablation with a BMI recorded and >30 kg/m 2 and at least 3 years of follow-up were included (n=407). The group was separated and compared by weight trends over the 3 years (1. Lost >3% of index weight, n=141; 2. Maintained index weight ±3%, n=147; 3. Gained >3% of index weight at 3 years, n=119). Long-term outcomes included AF recurrence and a composite defined as major adverse clinical events, MACE (stroke/TIA, heart failure (HF) hospitalization, and death). Results: The average age was 63.6±10.4 years, 59.3% were male and 51.7% had paroxysmal AF. AF comorbidities include: hypertension (79.5%), heart failure (36.0%), sleep apnea (35.2%), diabetes (28.9%), and stroke/TIA (5.9%). Those that maintained their weight (HR: 1.45, p=0.05) and those that gained weight (HR 1.54, p=0.07) were more likely to have AF recurrence compared to those that lost weight. Similarly, MACE increased from 18.4% in those that lost weight at 3 years compared to 18.6% (HR 1.32, p=0.29) in those that maintained their weight and 26.5% in those that gained weight (HR 2.01, p=0.02). A small group of patients (n=5), lost >3% then gained it back and ultimately increased their weight by 3%. This group had the highest rates of AF recurrence (100%). Conclusion: Maintained weight loss is a critical component in reducing AF recurrence rates after index catheter ablation in obese patients. Sustained weight loss also results in a reduction in AF-related comorbidities and mortality.


Sign in / Sign up

Export Citation Format

Share Document