scholarly journals Long Reach and High Capacity Hybrid Passive Optical Network

Author(s):  
Subhashini N ◽  
Brintha Therese A

<p>A number of applications are growing day by day and so the traffic. The need for bandwidth is also increasing at a rapid rate. The bandwidth and speed with which data can be transferred was very less when compared to core networks. The access network which was once a bottleneck is no longer so because of use of optic fiber (FTTH networks). A number of variants of Passive Optical Network (PON) have been proposed like the WDM PON and the Hybrid PON. Hybrid PON is a combination of TDM PON and WDM PON and is advantageous over WDMPON. This paper focuses on high capacity networks that can provide high data rate and long reach in the access part of the network. NRZ modulation format is normally used for transmission.  We consider the advantages provided by the advanced modulation formats like DPSK. This modulation format is used to here and its benefits are evaluated in Hybrid PON network to increase the capacity and the reach of the network. Parameters like the BER and the Q factors are analysed using Optisystem Software. Distortion and the phenomena of dispersion can limit the performance of such a system. Hence Dispersion compensation mechanisms like the Dispersion Compensation Fiber (DCF) are used in the system to transmit data over large distance.</p>

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Li Li ◽  
Li Hong-Jie

AbstractFor the commercial wavelength division multiplexing passive optical network (WDM-PON) with standard single-mode fiber SSMF-28 and 1:64 passive fiber branching at its far end (RN) and 100 GHz C-band continuous wavelength (CW) lasers, the maximum coverage and optimal transmission power of STM-16 and STM-64 with external modulators at different speeds and wave numbers (4λ, 8λ and 16λ) are obtained, respectively. The performance parameter of the high data rate WDM-PON system is analyzed with respect to a number of channels and reach. In order to improve the network utilization and receiving efficiency, the influence of different channels and transmission distances on the performance of high data rate WDM-PON system is analyzed. Simulation analysis with Optisystem15.0. The maximum transmission power required to achieve the maximum transmission distance under the condition of nonlinear constraints is obtained. In order to save power consumption, the configuration of each multi-band PON is optimized in terms of transmission power. It is found that WDM-PON system has to compromise between aggregated data rate and system reach. Future software defined access network reconfigure the access network depending on the dynamic demand and the resources available. Hence depending on the distance between the optical line terminal (OLT) and optical network unit (ONU) guaranteed data rate can be estimated. ONU is equipped with a tunable optical filter (TOF) hence future wavelength can be reconfigured by both service provider and user. It makes it possible for software to customize optical access network.


2016 ◽  
Vol 37 (3) ◽  
Author(s):  
Sooraj Parkash ◽  
Anurag Sharma ◽  
Harsukhpreet Singh

AbstractThis paper successfully demonstrates bidirectional wavelength division multiplexing passive optical network (WDM-PON) system for 32 channels, 0.8 nm (100 GHz) channels spacing with 3.5 GHz filter bandwidth. The system delivers 160 GB/s data rate and 80 GB/s data rate in downstream and upstream, respectively. The optical source for downstream data and upstream data is mode-locked laser at central office and reflective semiconductor optical amplifier (RSOA) at optical network unit. The maximum reach of designed system is 50 km without using any dispersion compensation scheme. This paper comprises comparison of series of modulation format in downstream and upstream such as SOLITON, NRZ, RZ, MANCHESTER, CSRZ and CRZ-DPSK and optimization of the performance of designed system. It has been observed that CRZ-DPSK/NRZ gives best performance in downstream and upstream transmission for designed system. The simulation work report of minimum BER is e


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Cheikh Kherici ◽  
Malika Kandouci

AbstractThe growth of optical technology is currently being studied extensively to meet the significant demand for bandwidth. The passive optical network (PON) solves the problem of bandwidth as it extends the optical network to individuals and businesses [Sifta R, Munster P, Krajsa O, Filka M, “Simulation of bidirectional traffic in WDM-PON networks", Brno University of Technology, ISSN 0033–2097, R. 90 NR 1/2014.]. In this paper, a comparative study is made between the WDM PON system and the CWDM PON system using two different architectures, one for the WDM PON and the other for the CWDM PON, to illustrate the appropriate technique for the PON network by increasing the Q factor and the OSNR ratio while minimizing the bit error rate (BER < 10–9). Both systems are simulated at 10 Gbps for four users of bidirectional SMF (Single Mode Fiber) fiber lengths and different powers. In order to determine the transmission performance for both systems, the link was designed for fiber lengths of 20, 30, 40, 50 and 60 km as well as for powers from −10 dBm up to 10 dBm for four users. The use of the EDFA amplifier in the WDM PON system is required in this document to minimize degradation caused by attenuation [Parkirti RDK, Singh R. Cost-efficient Colorless WDM-PON Based on RSOA for High Capacity. Int J Adv Res Comput Eng Technol (IJARCET). 2016;5]. On the contrary, in the CWDM PON system, the amplification is not essential because the wavelengths used in this system are not affected by the water peak which causes a strong attenuation of the wavelengths in the 1370–1410 nm range on optical fibers [Nazir M, Arshad F, Asif R. Design and evaluation of power budget for a bidirectional CWDM-Passive Optical Network. In: International Conference on Communication, Computing and Digital Systems (C-CODE), Islamabad, Pakistan, 04 May 2017.]. The peak of water vapor absorption is close to 1383 nm.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Devendra Kr. Tripathi ◽  
Pallavi Singh

Abstract Light-Fidelity (Li-Fi) is the bidirectional communication technique, tenders almost unlimited bandwidth, exploit unlicensed spectrum of light waves. Accordingly, this manuscript illustrates usage of visible light communication (VLC) applied as Li-Fi, an efficient scheme to broadcast data wirelessly as well safer technique in contrary to the customary Wireless-Fidelity (Wi-Fi) networks. In support numerical simulations have been executed over the proposed Li-Fi model for the parametric variation with the data rate, laser power, modulation format and wavelength, communication length. Investigations have showed good output performance, with hike in data rate BER variation as 10−94–10−23 and testing length. Simulations of network with DPSK and NRZ modulation formats at high data transmission of 10 Gbps have showed good output performance with 10−40 with DPSK format. Li-Fi systems are quality solution for the impending communication systems save cost, provide high spectral efficiency.


2019 ◽  
Vol 0 (0) ◽  
Author(s):  
Meet Kumari ◽  
Reecha Sharma ◽  
Anu Sheetal

AbstractNowadays, bandwidth demand is enormously increasing, that causes the existing passive optical network (PON) to become the future optical access network. In this paper, next generation passive optical network 2 (NG-PON2) based, optical time division multiplexing passive optical network (OTDM-PON), wavelength division multiplexing passive optical network (WDM-PON) and time & wavelength division multiplexing passive optical network (TWDM-PON) systems with 20 Gbps (8 × 2.5 Gbps) downstream and 20 Gbps (8 × 2.5 Gbps) upstream capacity for eight optical network units has been proposed. The performance has been compared by varying the input power (−6 to 27 dBm) and transmission distance (10–130 km) in terms of Q-factor and optical received power in the presence of fiber noise and non-linearities. It has been observed that TWDM-PON outperforms OTDM-PON and WDM-PON for high input power and data rate (20/20 Gbps). Also, TWDM-PON shows its superiority for long-reach transmission up to 130 km, which is a cost-effective solution for future NG-PON2 applications.


2015 ◽  
Vol 2015 ◽  
pp. 1-13 ◽  
Author(s):  
Shuai Chen ◽  
Wei Nai ◽  
Fangqi Zhang ◽  
Shaoyin Wang ◽  
Decun Dong ◽  
...  

Wavelength-division-multiplexing passive-optical-network (WDM-PON) has been recognized as a promising solution of the “last mile” access as well as multibroadband data services access for end users, and WDM-RoF-PON, which employs radio-over-fiber (RoF) technique in WDM-PON, is even a more attractive approach for future broadband fiber and wireless access for its strong availability of centralized multiservices transmission operation and its transparency for bandwidth and signal modulation formats. As for multiservices development in WDM-RoF-PON, various system designs have been reported and verified via simulation or experiment till now, and the scheme with multiservices transmitted in each single wavelength channel is believed as the one that has the highest bandwidth efficiency; however, the corresponding mathematical verification is still hard to be found in state-of-the-art literature. In this paper, system design and data transmission performance of a quintuple services integrated WDM-RoF-PON which jointly employs carrier multiplexing and orthogonal modulation techniques, have been theoretically analyzed and verified in detail; moreover, the system design has been duplicated and verified experimentally and the theory system of such WDM-RoF-PON scheme has thus been formed.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Shippu Sachdeva ◽  
Jagjit Malhotra ◽  
Manoj Kumar

Abstract Long reach Passive optical network (LR-PON) is an attractive solution to fulfill the ever-increasing bandwidth requirements due to propelling internet applications and competent to serve distant optical network units (ONUs). Wavelength division multiplexed (WDM) PON systems experience distance and performance limiting constraint termed as Dispersion. In order to compensate dispersion effects, Fiber bragg gratings (FBGs) and Dispersion compensation fibers (DCFs) are incorporated extensively in PONs. Performance of DCF is better than FBG in terms of dispersion compensation, but it comes at the cost of 3 $/m (very expensive). Therefore, long reach ultra dense WDM-PON systems are needed with incorporation of economical and high performance DCMs. Three newly constructed hybrid DCMs are investigated such as FBG-DCF (module 1), OPC-DCF (module 2), and FBG-DCF-OPC (module 3) in WDM-PON to get optimal DCM in terms of dispersion compensation efficiency (DCE) and economical operation. As per author’s best knowledge, DCE calculations and performance enhancement with cost reduction using hybrid DCMs in ultra dense WDM-PON, is not reported so far. WDM-PON consists of 32 channels at 25 GHz channel spacing is analyzed for 300 km link distance at 10 Gbps/channel using different hybrid DCMs. It is perceived that highest DCE of 70% is given by module 3 with maximum cost reduction of 19.84%. DCE performance of three modules is as follows: Module 3 (DCE 70%), Module 1 (DCE 55%), Module 2 (DCE 45%) and cost reduction/increase from conventional module by 19.84% reduction (Module 3), 19.05% reduction (Module 1), and increase 10.5% (Module 2). Hence, Module 3 is preferred for long reach WDM-PON to get high performance with lesser cost.


Author(s):  
RUCHI AGARWAL ◽  
VIVEKANAND MISHRA

In this paper, the implementation of subcarrier multiplexing technique is developed and investigated with pre-, post- and symmetrical-dispersion compensation methods for 10 Gb/s non-return to zero (NRZ) links using standard and dispersion compensated fibers through computer simulations to optimize high data rate optical transmission. Mathematical analysis is done to evaluate performance in term of bit error rate. Simulation is done using Optisys Software version 10.0. Motivation to this research is to compare all three compensation methods and it is found that the symmetrical compensation method is superior to pre- and post-compensation methods. On comparing pre- and post-compensation methods, it is found that the later is superior to the former. A 10-Gb/s SCM test bed has been set up in which 4 * 2.5 Gb/s data streams are combined into one wavelength that occupies a 20-GHz optical bandwidth. Thus by using these comparisions one can get a promising system to the symmetric high capacity access network with high spectral efficiency, cost effective, good flexibility.


2015 ◽  
Vol 36 (4) ◽  
Author(s):  
Yousef Fazea ◽  
Angela Amphawan

AbstractWavelength-division multiplexed-passive optical network (WDM-PON) is a revolutionary high-capacity and scalable broadband access network. This paper capitalizes on Laguerre–Gaussian (LG) modes to reduce modal dispersion and increase data capacity. A data rate of 25 Gbit/s is attained for a multimode fiber link by multiplexing five LG modes on five wavelengths centered at 1,550.12 nm for a distance up to 800 m.


2014 ◽  
Vol 700 ◽  
pp. 181-184
Author(s):  
Xu Zhang ◽  
Peng Chao Han ◽  
Yin Peng Yu ◽  
Yu Fang Zhou ◽  
Ya Min Xie

As one of promising "last mile" scheme for broadband access network, Fiber-Wireless (FiWi) access network has the advantages of high capacity, long distance, low cost etc because it is the integration of optical back-end and wireless front-end. At the same time, energy consumption of FiWi access network is an important factor that limits the development of networks. A number of ONU sleep states such as ONU power shedding state, ONU doze state, ONU deep sleep state and ONU fast sleep state have been proposed to obtain low-power ONU state, which indirectly reduce energy consumption of networks. However, these low-power states of ONU are born to coordinate to green Passive Optical Network (PON), of which the function of ONU is different from FiWi. In this paper, two low power ONU sleep mechanisms called Static ONU Sleep (SOS) mechanism and Dynamic ONU Sleep (DOS) mechanism, respectively, are proposed and embedded into FiWi access network. By simulation and analysis based on OPNET 14.5, this paper shows that the DOS mechanism has a better performance than SOS, and both of them can save energy of FiWi access network.


Sign in / Sign up

Export Citation Format

Share Document