Predictive Direct Power Control (PDPC) of Grid-connected Dual-active Bridge Multilevel Inverter (DABMI)

Author(s):  
H.H. Goh ◽  
Azuwien Aida ◽  
S.S. Lee ◽  
S.Y. Sim ◽  
K.C. Goh

This paper deals with controlling a grid-connected dual-active bridge multilevel inverter for renewable energy integration. The concept of direct power control is integrated with model predictive control algorithm, which is termed as predictive direct power control, to control the real and reactive power injected into the power grid. The proposed multilevel inverter allows more options of feasible voltage vectors for switching vector selections in order to generate multilevel outputs, and thereby obtaining high power quality in the power grid. By using the predictive direct power control, simulation results show that the proposed multilevel inverter produces lower power ripple and manage to achieve currents with low total harmonic distortion which are well within the IEEE standard. The modeling and simulation of the system are implemented and validated by MATLAB Simulink software.

Author(s):  
Azziddin M. Razali ◽  
Nor Azizah Yusoff ◽  
Kasrul Abdul Karim ◽  
Auzani Jidin ◽  
Tole Sutikno

This paper presents a comprehensive and systematic approach in developing a new switching look-up table for direct power control (DPC) strategy applied to the three-phase grid connected three-level neutral-point clamped (3L-NPC) pulse width modulated (PWM) rectifier. The term of PWM rectifier used in this paper is also known as AC-DC converter. The approach provides detailed information regarding the effects of each multilevel converter space vector to the distribution of input active and reactive power in the converter system. Thus, the most optimal converter space vectors are able to be selected by the switching look-up table, allowing smooth control of the active and reactive powers for each sector. In addition, the proposed DPC utilizes an NPC capacitor balanced strategy to enhance the performance of front-end AC-DC converter during load and supply voltage disturbances. The steady state as well as the dynamic performances of the proposed DPC are presented and analyzed by using MATLAB/Simulink software. The results show that the AC-DC converter utilizing the new look-up table is able to produce almost sinusoidal line currents with lower current total harmonic distortion, unity power factor operation, adjustable DC-link output voltage and good dynamic response during load disturbance.


Energies ◽  
2020 ◽  
Vol 13 (11) ◽  
pp. 2951 ◽  
Author(s):  
Azuwien Aida Bohari ◽  
Hui Hwang Goh ◽  
Agustiono Kurniawan Tonni ◽  
Sze Sing Lee ◽  
Sy Yi Sim ◽  
...  

This paper explores the feasibility of multilevel dual-active bridge-inverter (DABMI) applications for grid-connected applications of a modern Model of Predictive Direct Power Control (MPDPC) based on the conservative power theory (CPT). In the case of unbalanced grid voltages, the objective of the study is to promote continued active and reactive energy in MPDPC without reducing efficiency such as transient response and current harmonics. The nature of the instantaneous p-q theory permits only one out of three control targets to be fulfilled. The proposed control approached directly regulates the instantaneous active and reactive power to achieve three particular control objectives namely sinusoidal and symmetrical grid current, cancelling twice of fundamental grid frequency reactive power ripples, and removing twice grid frequency active power ripple. The techniques of complicated Grid part sequence extraction are unnecessary and improved at no extra expense, as is the case with current MPDPC fault-tolerant approaches. The instantaneous power at the next sampling instant is predicted with the newly developed discrete-time model. Each possible switching state will then be evaluated in the cost function defined until the optimal state which lead to the minimum power errors is determined. In MATLAB/Simulink simulation, the proposed CPT-based MPDPC measures reliability and performance at balanced and unbalanced grid voltages then compared with the conventional and existing MPDPC The proposed method manages to achieve all of three control targets which generates sinusoidal grid currents and attenuates active and reactive power ripple of twice the grid frequency exactly at the same time without losing its critical efficiency including transient reaction and current harmonics.


Author(s):  
Z.E.Z. Laggoun ◽  
H. Benalla ◽  
K. Nebti

Introduction. The quality of electrical energy is essential during disturbances, at the level of power electronic devices will suffer serious operating problems causing dangerous damage. Aim. A new approach to direct power control without grid voltage sensor improves the quality and control of instantaneous active and reactive power converters. Methodology. First, the technique without network voltage sensor with a direct power control based on a switching table, which is a classic approach, is discussed and its performance is analyzed under increasing and decreasing load. In addition, the performance of the proposed technique is also analyzed under the same circumstances and their performance is compared. Originality. The new method consists of a nonlinear grid voltage modulated controller and a conventional controller which guarantees very good results in a polluted network. The proposed method is verified using MATLAB/Simulink. Results. The simulation results under different input voltage conditions show that the proposed method not only has good tracking performance in active and reactive power, but also reduces the current total harmonic distortion to 1.9 %, which is good lower than the requirement for network operation.


2013 ◽  
Vol 441 ◽  
pp. 328-331
Author(s):  
Hui Zhao ◽  
Biao Wang ◽  
Hong Jun Wang ◽  
You Jun Yue

In this paper, we study a modified predictive direct power control scheme (P-DPC).This scheme which based on model predictive control (MPC) uses a discrete rectifier model to infer the predictive direct power control theme again, and selects the operating time of voltage vector and voltage vector to realize fixed switching frequency through setting the minimum power errors of each sampling period. This control scheme has a lower switching frequency compared to MP-DPC; and it is still simple and clear implemented in the stationary reference frame directly, meanwhile, it does not need PI controllers or voltage-oriented controllers compared to other developed control schemes. We make simulations using MATLAB. The result show the excellence of this novel predictive direct power control scheme through improving the switching frequency, current THD and active power and reactive power quality compared to MP-DPC and LUT-DPC.


Author(s):  
Arezki Fekik ◽  
Hakim Denoun ◽  
Ahmad Taher Azar ◽  
Mustapha Zaouia ◽  
Nabil Benyahia ◽  
...  

In this chapter, a new technique has been proposed for reducing the harmonic content of a three-phase PWM rectifier connected to the networks with a unit power factor and also providing decoupled control of the active and reactive instantaneous power. This technique called direct power control (DPC) is based on artificial neural network (ANN) controller, without line voltage sensors. The control technique is based on well-known direct torque control (DTC) ideas for the induction motor, which is applied to eliminate the harmonic of the line current and compensate for the reactive power. The main idea of this control is based on active and reactive power control loops. The DC voltage capacitor is regulated by the ANN controller to keep it constant and also provides a stable active power exchange. The simulation results are very satisfactory in the terms of stability and total harmonic distortion (THD) of the line current and the unit power factor.


Author(s):  
Fawzi Senani

<span lang="EN-US">The paper presents the complete modeling and control strategy of variable speed wind turbine system (WTS) driven doubly fed induction generators (DFIG). A back-to-back converter is employed for the power conversion exchanged between DFIG and grid. The wind turbine is operated at the maximum power point tracking (MPPT) mode its maximum efficiency. Direct power control (DPC) based on selecting of the appropriate rotor voltage vectors and the errors of the active and reactive power, the control strategy of rotor side converter combines the technique of MPPT and direct power control. In the control system of the grid side converter the direct power control has been used to maintain a constant DC-Link voltage, and the reactive power is set to 0. Simulations results using MATLAB/SIMULINK are presented and discussed on a 1.5MW DFIG wind generation system demonstrate the effectiveness of the proposed control.</span>