Use of Electromagnetic Navigational Bronchoscopy in Conjunction with Endobronchial Ultrasound Transbronchial Needle Aspiration to Increase the Diagnostic Yield in Patients with Pulmonary Nodules and Mediastinal Adenopathy: A Case Series

Author(s):  
R. Steff ◽  
J. Moore ◽  
A. Bauer ◽  
M.A. Ahmed ◽  
F.Z. Cheema
Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2331
Author(s):  
Huzaifa A. Jaliawala ◽  
Samid M. Farooqui ◽  
Kassem Harris ◽  
Tony Abdo ◽  
Jean I. Keddissi ◽  
...  

Since the endobronchial ultrasound bronchoscope was introduced to clinical practice, endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) has become the procedure of choice to sample hilar and mediastinal adenopathy. Multiple studies have been conducted in the last two decades to look at the different technical aspects of the procedure and their effects on the final cytopathological yield. In addition, newer modes of ultrasound scanning and newer tools with the potential to optimize the selection and sampling of the target lymph node have been introduced. These have the potential to reduce the number of passes, reduce the procedure time, and increase the diagnostic yield, especially in rare tumors and benign diseases. Herein, we review the latest updates related to the technical aspects of EBUS-TBNA and their effects on the final cytopathological yield in malignant and benign diseases.


Respiration ◽  
2021 ◽  
pp. 1-5
Author(s):  
Zan-Sheng Huang ◽  
Dong Zhou ◽  
Jing Zhang ◽  
Wan-Lei Fu ◽  
Jing Wang ◽  
...  

Guidelines have recommended endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) and endoscopic ultrasound-guided fine-needle aspiration biopsy as initial sampling approaches of mediastinal lymph nodes for lung cancer staging. However, the small sample volume might restrict the diagnostic utility of needle aspiration in certain mediastinal diseases. We have recently shown that transbronchial mediastinal cryobiopsy, which is capable of providing larger amounts of intact tissue, improves diagnostic yield in rare tumors and benign diseases compared to EBUS-TBNA. Here, we present a case of mediastinal nodular lymphocyte predominant Hodgkin lymphoma successfully diagnosed by endoscopic transesophageal cryobiopsy.


2016 ◽  
Vol 42 (4) ◽  
pp. 248-253 ◽  
Author(s):  
Marcia Jacomelli ◽  
Sergio Eduardo Demarzo ◽  
Paulo Francisco Guerreiro Cardoso ◽  
Addy Lidvina Mejia Palomino ◽  
Viviane Rossi Figueiredo

ABSTRACT Objective: Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. Methods: We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. Results: Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm) and 19 masses (mean diameter, 4.1 ± 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). Conclusions: Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions.


2015 ◽  
Vol 41 (3) ◽  
pp. 219-224 ◽  
Author(s):  
Sebastián Fernández-Bussy ◽  
Gonzalo Labarca ◽  
Sofia Canals ◽  
Iván Caviedes ◽  
Erik Folch ◽  
...  

OBJECTIVE: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a minimally invasive diagnostic test with a high diagnostic yield for suspicious central pulmonary lesions and for mediastinal lymph node staging. The main objective of this study was to describe the diagnostic yield of EBUS-TBNA for mediastinal lymph node staging in patients with suspected lung cancer. METHODS: Prospective study of patients undergoing EBUS-TBNA for diagnosis. Patients ≥ 18 years of age were recruited between July of 2010 and August of 2013. We recorded demographic variables, radiological characteristics provided by axial CT of the chest, location of the lesion in the mediastinum as per the International Association for the Study of Lung Cancer classification, and definitive diagnostic result (EBUS with a diagnostic biopsy or a definitive diagnostic method). RESULTS: Our analysis included 354 biopsies, from 145 patients. Of those 145 patients, 54.48% were male. The mean age was 63.75 years. The mean lymph node size was 15.03 mm, and 90 lymph nodes were smaller than 10.0 mm. The EBUS-TBNA method showed a sensitivity of 91.17%, a specificity of 100.0%, and a negative predictive value of 92.9%. The most common histological diagnosis was adenocarcinoma. CONCLUSIONS: EBUS-TBNA is a diagnostic tool that yields satisfactory results in the staging of neoplastic mediastinal lesions.


Author(s):  
Michael Barker ◽  
Annette Günther ◽  
Henrik Wurps ◽  
Andreas Gebhardt ◽  
Nicolas Schönfeld ◽  
...  

Referring to a literature review published recently in this Journal, we report a single-center case series of 45 children and adolescents (age 2-17 years) with suspected tuberculosis (TB) and negative microscopy on repeated sputum or gastric aspirate samples. All subjects underwent flexible airway endoscopy including bronchoalveolar lavage (BAL) and endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) without adverse events. Among 41 subjects with a final TB diagnosis, Mycobacterium tuberculosis was detected by PCR and/or culture in 20 (49% bacteriological confirmation) with 11 cases relying exclusively on results from TBNA samples. Only 7 of 17 positive culture results related to sputum (17% confirmation rate), and 9 of 17 on the combination of sputum and BAL (22%) respectively. The sampling site of a person’s first positive culture was TBNA in 13 of 17 cases (76%). Bacteriological confirmation was essential for diagnostic accuracy and tailored treatment based on individual drug susceptibility testing. We therefore recommend the inclusion of bronchoscopy and EBUS-TBNA in a comprehensive diagnostic protocol for smear-negative pediatric TB suspects.


CytoJournal ◽  
2011 ◽  
Vol 8 ◽  
pp. 20 ◽  
Author(s):  
Adrienne Carruth Griffin ◽  
Lauren Ende Schwartz ◽  
Zubair W. Baloch

Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an integral tool in the diagnosis and staging of malignant tumors of the lung. Rapid on-site evaluation (ROSE) of fine needle aspiration (FNA) samples has been advocated for as a guide for assessing the accuracy and adequacy of biopsy samples. Although ROSE has proven useful for numerous sites and procedures, few studies have specifically investigated its utility in the assessment of EBUS-TBNA specimens. The intention of this study was to explore the utility of ROSE for EBUS-TBNA specimens. Materials and Methods: The pathology files at our institution were searched for all EBUS-TBNA cases performed between January 2010 and June 2010. The data points included number of sites sampled per patient, location of site(s) sampled, on-site evaluation performed, preliminary on-site diagnosis rendered, final cytologic diagnosis, surgical pathology follow-up, cell blocks, and ancillary studies performed. Results: A total of 294 EBUS-TBNA specimens were reviewed and included in the study; 264 of 294 (90%) were lymph nodes and 30 of 294 (10%) were lung mass lesions. ROSE was performed for 140 of 294 (48%) specimens. The on-site and final diagnoses were concordant in 104 (74%) and discordant in 36 (26%) cases. Diagnostic specimens were obtained in 132 of 140 (94%) cases with on-site evaluation and 138 of 154 (90%) without on-site evaluation. The final cytologic diagnosis was malignant in 60 of 132 (45%) cases with ROSE and 46 of 138 (33%) cases without ROSE, and the final diagnosis was benign in 57 of 132 (47%) with ROSE and 82 of 138 (59%) without ROSE. A cell block was obtained in 129 of 140 (92%) cases with ROSE and 136 of 154 (88%) cases without ROSE. Conclusions: The data demonstrate no remarkable difference in diagnostic yield, the number of sites sampled per patient, or clinical decision making between specimens collected via EBUS-TBNA with or without ROSE. As a result, this study challenges the notion that ROSE is beneficial for the evaluation of EBUS-TBNA specimens.


2020 ◽  
Vol 13 (12) ◽  
pp. e239170
Author(s):  
David Quigley ◽  
Parthiban Nadarajan ◽  
Finbar O Connell

Endobronchial ultrasound (EBUS) has long been a common diagnostic tool used in the diagnosis of pulmonary pathologies. In the last decade, increased interest has been shown in its usage via the oesophagus for sampling lesions inaccessible via the airways. We describe three cases in which we used this modality to biopsy lesions not visualised via conventional EBUS and which would be too risky to be attempted via a CT-guided biopsy with a high likelihood of complications. More focused education on using EBUS via the oesophagus for respiratory trainees could greatly improve overall clinical practice. It improves the diagnostic yield of lesions and prevents subsequent referral to gastrointestinal colleagues which may delay diagnosis especially during the COVID-19 pandemic as was the case in our patient cohort where services are already limited. EBUS, due to its smaller size, is less irritant to the upper airways and requires less sedation than endoscopic ultrasound (EUS) scopes. It is also shorter than an EUS scope improving manoeuvrability. Each of our cases resulted in early histological diagnosis and subsequent appropriate treatment.


Sign in / Sign up

Export Citation Format

Share Document