Determination of cotton fiber maturity and linear density (fineness) by examination of fiber cross-sections. Part 2: A comparison optical and scanning electron microscopy

2014 ◽  
Vol 84 (18) ◽  
pp. 1939-1947 ◽  
Author(s):  
Geoffrey RS Naylor ◽  
Margaret Pate ◽  
Graham J Higgerson

Previous researchers established a set of reference cottons with known fiber maturity and linear density (fineness) values based on the analysis of a large number of individual transverse fiber cross-sections viewed under the optical microscope. Part 1 identified that the limited optical resolution of the captured images may be the source of a significant systematic error in the assigned values of cell wall area and hence fiber maturity and linear density values. In this paper the optical microscopy technique was implemented. Individual cross-sections were measured using this approach and also higher resolution and higher magnification images were obtained using scanning electron microscopy. It was found that the data obtained from optical microscopy were similar to the SEM data, with the perimeter being 2% smaller, the cell wall area being 6% larger and the maturity ratio values being 8% higher. It was concluded that the combined approach of utilizing SEM in conjunction with optical imaging is a useful approach for verifying and perhaps correcting the data obtained from optical imaging. Further the SEM images highlighted that the current experimental protocol does not adequately address the challenge of ensuring that the fibers are mounted normal to the plane of cutting the transverse cross-section. Modeling demonstrated that while maturity ratio values are relatively insensitive to this misalignment, measured cell wall area values and hence fiber linear density values will be overestimated. This may be the major source of error associated with the technique and warrants further attention in future studies.

Author(s):  
M.E. Lee ◽  
A. Moller ◽  
P.S.O. Fouche ◽  
I.G Gaigher

Scanning electron microscopy of fish scales has facilitated the application of micro-structures to systematics. Electron microscopy studies have added more information on the structure of the scale and the associated cells, many problems still remain unsolved, because of our incomplete knowledge of the process of calcification. One of the main purposes of these studies has been to study the histology, histochemistry, and ultrastructure of both calcified and decalcified scales, and associated cells, and to obtain more information on the mechanism of calcification in the scales. The study of a calcified scale with the electron microscope is complicated by the difficulty in sectioning this material because of the close association of very hard tissue with very soft tissues. Sections often shatter and blemishes are difficult to avoid. Therefore the aim of this study is firstly to develop techniques for the preparation of cross sections of fish scales for scanning electron microscopy and secondly the application of these techniques for the determination of the structures and calcification of fish scales.


Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quaity positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).The problem for many researchers, however, is that they have perfectly serviceable microscopes that they routinely use that have no digital imaging capabilities with little hope of purchasing a new instrument.


Author(s):  
J. S. Shah ◽  
R. Durkin ◽  
A. N. Farley

It is now possible to perform High Pressure Scanning Electron Microscopy (HPSEM) in the range 10 to 2000 Pa. Here the effect of scattering on resolution has been evaluated by calculating the profile of the beam in high pressure and assessing its effect on the image contrast . An experimental scheme is presented to show that the effect of the primary beam ionization is to reduce image contrast but this effect can be eliminated by a novel use of specimen current detection in the presence of an electric field. The mechanism of image enhancement is discussed in terms of collection of additional carriers generated by the emissive components.High Pressure SEM (HPSEM) instrumentation is establishing itself as commercially viable. There are now a number of manufacturers, such as JEOL, ABT, ESCAN, DEBEN RESEARCH, selling microscopes and accessories for HPSEM. This is because high pressure techniques have begun to yield high quality micrographs at medium resolution.To study the effect of scattering on the incident electron beam, its profile - in a high pressure environment - was evaluated by calculating the elastic and inelastic scattering cross sections for nitrogen in the energy range 5-25 keV. To assess the effect of the scattered beam on the image contrast, the modification of a sharp step contrast function due to scattering was calculated by single scattering approximation and experimentally confirmed for a 20kV accelerated beam.


2013 ◽  
Vol 47 ◽  
pp. 13-20
Author(s):  
O. V. Anissimova

Algae samples were collected during different seasons from 1997 to 2011 in two swamps located at Zvenigorod Biological Station in Moscow Region. There were found 25 Cosmarium species and varieties, 9 taxa of them being new to the region. Descriptions of the taxa were specified by observation of cell wall ornamentation with light and scanning electron microscopy. Original descriptions, photos and drawings of algae are presented.


2018 ◽  
Author(s):  
Lo Chea Wee ◽  
Tan Sze Yee ◽  
Gan Sue Yin ◽  
Goh Cin Sheng

Abstract Advanced package technology often includes multi-chips in one package to accommodate the technology demand on size & functionality. Die tilting leads to poor device performance for all kinds of multi-chip packages such as chip by chip (CbC), chip on chip (CoC), and the package with both CbC and CoC. Traditional die tilting measured by optical microscopy and scanning electron microscopy has capability issue due to wave or electron beam blocking at area of interest by electronic components nearby. In this paper, the feasibility of using profilemeter to investigate die tilting in single and multi-chips is demonstrated. Our results validate that the profilemeter is the most profound metrology for die tilting analysis especially on multi-chip packages, and can achieve an accuracy of <2μm comparable to SEM.


Author(s):  
J R Santos-Mallet ◽  
T D Balthazar ◽  
A A Oliveira ◽  
W A Marques ◽  
A Q Bastos ◽  
...  

Abstract The aim of the present study was to describe the morphology of the eggs of Culex (Culex) saltanensis Dyar that occurs in the Neotropical region. Eggs of the Cx. (Cux.) saltanensis were collected at the Mata Atlântica FIOCRUZ campus, fixed in 1% osmium tetroxide, prepared for mounting on metal supports, observed under a scanning electron microscope, and described morphologically. The eggs had a coniform shape with a length of approximately 0.5 mm (505–510 µm) and a width in the median portion of 117 µm (113–123 µm). Upper portion is lined with tubers of irregular shape and varying sizes (0.64–1.31 µm), located on a cross-linked matrix forming bands observed under optical microscopy. The micropyle is encased in a necklace of approximately 6.6-µm plates arranged in a flower-like shape. Comparing Cx. (Cux.) saltanensis eggs with several species of different genera, important divergent characteristics can be observed. However, this study points to the need for new descriptions of eggs of species belonging to the same subgenus in order to analyze if there will be differences between them. Culex (Cux.) saltanensis eggs have particular characteristics not observed in eggs of other Culicidae genera.


2007 ◽  
Vol 537-538 ◽  
pp. 303-306
Author(s):  
Tamás Bíró ◽  
László Dévényi

This paper shows the result of some metallographical examinations that have been carried out on low-alloyed Cr-Mo-V heat resistant steel. The aim of this research is to present and compare the advantages and disadvantages of the mainly applied metallographical methods. These techniques are optical microscopy, scanning electron microscopy, replica method and special applications of these methods. We have proved that using the investigated methods together gives much more information about the lifetime of the specimen than using these techniques particularly.


1997 ◽  
Vol 5 (4) ◽  
pp. 14-15
Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quality positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).


Sign in / Sign up

Export Citation Format

Share Document