Damage Analysis of Heat Resistant Steels

2007 ◽  
Vol 537-538 ◽  
pp. 303-306
Author(s):  
Tamás Bíró ◽  
László Dévényi

This paper shows the result of some metallographical examinations that have been carried out on low-alloyed Cr-Mo-V heat resistant steel. The aim of this research is to present and compare the advantages and disadvantages of the mainly applied metallographical methods. These techniques are optical microscopy, scanning electron microscopy, replica method and special applications of these methods. We have proved that using the investigated methods together gives much more information about the lifetime of the specimen than using these techniques particularly.

Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quaity positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).The problem for many researchers, however, is that they have perfectly serviceable microscopes that they routinely use that have no digital imaging capabilities with little hope of purchasing a new instrument.


2018 ◽  
Author(s):  
Lo Chea Wee ◽  
Tan Sze Yee ◽  
Gan Sue Yin ◽  
Goh Cin Sheng

Abstract Advanced package technology often includes multi-chips in one package to accommodate the technology demand on size & functionality. Die tilting leads to poor device performance for all kinds of multi-chip packages such as chip by chip (CbC), chip on chip (CoC), and the package with both CbC and CoC. Traditional die tilting measured by optical microscopy and scanning electron microscopy has capability issue due to wave or electron beam blocking at area of interest by electronic components nearby. In this paper, the feasibility of using profilemeter to investigate die tilting in single and multi-chips is demonstrated. Our results validate that the profilemeter is the most profound metrology for die tilting analysis especially on multi-chip packages, and can achieve an accuracy of <2μm comparable to SEM.


Author(s):  
J R Santos-Mallet ◽  
T D Balthazar ◽  
A A Oliveira ◽  
W A Marques ◽  
A Q Bastos ◽  
...  

Abstract The aim of the present study was to describe the morphology of the eggs of Culex (Culex) saltanensis Dyar that occurs in the Neotropical region. Eggs of the Cx. (Cux.) saltanensis were collected at the Mata Atlântica FIOCRUZ campus, fixed in 1% osmium tetroxide, prepared for mounting on metal supports, observed under a scanning electron microscope, and described morphologically. The eggs had a coniform shape with a length of approximately 0.5 mm (505–510 µm) and a width in the median portion of 117 µm (113–123 µm). Upper portion is lined with tubers of irregular shape and varying sizes (0.64–1.31 µm), located on a cross-linked matrix forming bands observed under optical microscopy. The micropyle is encased in a necklace of approximately 6.6-µm plates arranged in a flower-like shape. Comparing Cx. (Cux.) saltanensis eggs with several species of different genera, important divergent characteristics can be observed. However, this study points to the need for new descriptions of eggs of species belonging to the same subgenus in order to analyze if there will be differences between them. Culex (Cux.) saltanensis eggs have particular characteristics not observed in eggs of other Culicidae genera.


Biology ◽  
2021 ◽  
Vol 10 (1) ◽  
pp. 51
Author(s):  
Michela Relucenti ◽  
Giuseppe Familiari ◽  
Orlando Donfrancesco ◽  
Maurizio Taurino ◽  
Xiaobo Li ◽  
...  

Several imaging methodologies have been used in biofilm studies, contributing to deepening the knowledge on their structure. This review illustrates the most widely used microscopy techniques in biofilm investigations, focusing on traditional and innovative scanning electron microscopy techniques such as scanning electron microscopy (SEM), variable pressure SEM (VP-SEM), environmental SEM (ESEM), and the more recent ambiental SEM (ASEM), ending with the cutting edge Cryo-SEM and focused ion beam SEM (FIB SEM), highlighting the pros and cons of several methods with particular emphasis on conventional SEM and VP-SEM. As each technique has its own advantages and disadvantages, the choice of the most appropriate method must be done carefully, based on the specific aim of the study. The evaluation of the drug effects on biofilm requires imaging methods that show the most detailed ultrastructural features of the biofilm. In this kind of research, the use of scanning electron microscopy with customized protocols such as osmium tetroxide (OsO4), ruthenium red (RR), tannic acid (TA) staining, and ionic liquid (IL) treatment is unrivalled for its image quality, magnification, resolution, minimal sample loss, and actual sample structure preservation. The combined use of innovative SEM protocols and 3-D image analysis software will allow for quantitative data from SEM images to be extracted; in this way, data from images of samples that have undergone different antibiofilm treatments can be compared.


1997 ◽  
Vol 5 (4) ◽  
pp. 14-15
Author(s):  
John F. Mansfield

The current imaging trend in optical microscopy, scanning electron microscopy (SEM) or transmission electron microscopy (TEM) is to record all data digitally. Most manufacturers currently market digital acquisition systems with their microscope packages. The advantages of digital acquisition include: almost instant viewing of the data as a high-quality positive image (a major benefit when compared to TEM images recorded onto film, where one must wait until after the microscope session to develop the images); the ability to readily quantify features in the images and measure intensities; and extremely compact storage (removable 5.25” storage devices which now can hold up to several gigabytes of data).


2003 ◽  
Vol 18 (9) ◽  
pp. 2050-2054 ◽  
Author(s):  
Marcello Gombos ◽  
Vicente Gomis ◽  
Anna Esther Carrillo ◽  
Antonio Vecchione ◽  
Sandro Pace ◽  
...  

In this work, we report on the observation of Nd1Ba6Cu3O10,5 (Nd163) phase of the NdBaCuO system in melt-textured Nd123 bulk samples grown from a mixture of Nd123 and Nd210 phase powders. The observation was performed with polarized light optical microscopy and scanning electron microscopy–energy dispersive x-ray analyses. Images of the identified phase crystals show an aspect quite different from Nd422 crystals. Unexpectedly, Nd163 was individuated, even in “pure” Nd123 samples. Moreover, after long exposure to air, Nd163 disappeared completely in samples synthesized from powders containing Nd210. Thermogravimetry analyses of powders show that the stability of this phase in air is limited to temperatures higher than 900 °C, so Nd163 is unstable and highly reactive at room temperature. Moreover, an explanation of the observation of Nd163 in Nd210 free samples, based on the spontaneous formation of Nd163 phase in a Nd123 melt, is proposed.


2014 ◽  
Vol 84 (18) ◽  
pp. 1939-1947 ◽  
Author(s):  
Geoffrey RS Naylor ◽  
Margaret Pate ◽  
Graham J Higgerson

Previous researchers established a set of reference cottons with known fiber maturity and linear density (fineness) values based on the analysis of a large number of individual transverse fiber cross-sections viewed under the optical microscope. Part 1 identified that the limited optical resolution of the captured images may be the source of a significant systematic error in the assigned values of cell wall area and hence fiber maturity and linear density values. In this paper the optical microscopy technique was implemented. Individual cross-sections were measured using this approach and also higher resolution and higher magnification images were obtained using scanning electron microscopy. It was found that the data obtained from optical microscopy were similar to the SEM data, with the perimeter being 2% smaller, the cell wall area being 6% larger and the maturity ratio values being 8% higher. It was concluded that the combined approach of utilizing SEM in conjunction with optical imaging is a useful approach for verifying and perhaps correcting the data obtained from optical imaging. Further the SEM images highlighted that the current experimental protocol does not adequately address the challenge of ensuring that the fibers are mounted normal to the plane of cutting the transverse cross-section. Modeling demonstrated that while maturity ratio values are relatively insensitive to this misalignment, measured cell wall area values and hence fiber linear density values will be overestimated. This may be the major source of error associated with the technique and warrants further attention in future studies.


2012 ◽  
Vol 535-537 ◽  
pp. 996-999 ◽  
Author(s):  
Bao Feng Zhang ◽  
Qi Chen ◽  
Xiao Wei Chen ◽  
Hong Liang Zhao

In this study, the effect of KBF4 addition on the microstructure of the Mg-6Zn-1Si alloy has been investigated by Optical Microscopy (OM), Scanning Electron Microscopy (SEM) with Energy Dispersive Spectrometer(EDS). At 1.5wt% KBF4 addition, the morphology of Mg2Si phase completely changed from Chinese script type into uniformly, dispersedly distributed graininess or small block, with the average size of the Mg-6Zn-1Si alloy decreasing from 135μm to 82μm.


2016 ◽  
Vol 881 ◽  
pp. 422-426
Author(s):  
Carlos Maurício Fontes Vieira ◽  
Regina Maria Pinheiro ◽  
Sergio Neves Monteiro

This work has for objective to evaluate the microstructure of clayey ceramic incorporated with a waste in the form of sludge generated during treatment of effluent of a paper making industry. The microstructure of ceramics incorporated with 0 and 10 wt.% of waste, and then fired at 600°C, was evaluated by optical microscopy, scanning electron microscopy and X-ray diffraction. The results showed that the waste changes the microstructure of the clayey ceramic increasing the porosity, as well as forming new crystalline phases, mainly with calcium compounds.


Zootaxa ◽  
2019 ◽  
Vol 4619 (3) ◽  
pp. 401-430 ◽  
Author(s):  
NESTOR FERNANDEZ ◽  
PIETER THERON ◽  
SERGIO LEIVA ◽  
ANINE JORDAAN

Diplobodes africanus Mahunka, 1987, is redescribed by using Scanning Electron Microscopy (SEM) in order to complement optical microscopy. Diplobodes thailande sp. nov. from Thailand is described. For both species we include inclined views, to permit detailed analysis of ventral regions and to aid understanding of the complex relationships between elevated and depressed zones. Diplobodes thailande sp. nov. presents previously undescribed structures on legs III, which are involved in the leg folding process. Rwandabodes kayoveae gen. nov., sp. nov. presents a series of particular characteristics, such as: elevated interlamellar process on prodorsum, composed of a triangular structure, externally delimited by a low lamellar furrow; in setae inserted on elevated interlamellar process; large free lamellar tip; notogaster lacking ridges; anterior genital furrow extends into an oblique lateral depression; depressed area anterior to anal zone; both zones clearly delimited. These characteristics permit easy differentiation from related genera. 


Sign in / Sign up

Export Citation Format

Share Document