scholarly journals An Evaluation of Body Temperature Measurement

1983 ◽  
Vol 11 (1) ◽  
pp. 31-39 ◽  
Author(s):  
A. H. Ilsley ◽  
A. J. Rutten ◽  
W. B. Runciman

The accuracy of routine body temperature measurements, the suitability of various sites for such measurements, and the performance and practicality of various temperature measuring devices were studied. Oral and axillary temperature measurements made by the nursing staff were within 1°C of a reference value (within 0.5 °C in 67%). Both sites were suitable for routine ward temperature measurement. Mercury-in-glass thermometers are recommended for routine ward use. Electronic and disposable chemical thermometers cost more but the latter are suitable in uncooperative patients and children. Forehead skin temperature measurements using liquid crystal plastic discs were unreliable. Pulmonary artery and rectal temperature measurements were satisfactory in operating theatre and intensive care unit; however, electronic thermometers should be subjected to routine checks. The bladder temperature measuring device proved unsuitable for clinical use. When oesophagus, nasopharynx and tympanum sites are used careful placement is necessary to minimise trauma and obtain reliable measurements.

2019 ◽  
Vol 11 (2) ◽  
pp. 1123
Author(s):  
Ulul Ilmi

Measurement is the process of comparing measuring devices against measured objects. For measurement of magnitude, a measurement tool is needed. In this research activity, the object to be measured is the temperature at the metal expansion. To realize this goal, it is necessary to study the temperature measuring device on the metal expansion. The sensor used for temperature measuring devices is LM35 which is equipped by Arduino and LCD. Based on the test results obtained voltage values measured by a multimeter with an LCD display close to 100 percent or about 99.99 percent. With these results, it can be concluded that the temperature measurement meter is in accordance with the expected research objectives.


2009 ◽  
Vol 44 (2) ◽  
pp. 124-135 ◽  
Author(s):  
Matthew S. Ganio ◽  
Christopher M. Brown ◽  
Douglas J. Casa ◽  
Shannon M. Becker ◽  
Susan W. Yeargin ◽  
...  

Abstract Context: When assessing exercise hyperthermia outdoors, the validity of certain commonly used body temperature measuring devices has been questioned. A controlled laboratory environment is generally less influenced by environmental factors (eg, ambient temperature, solar radiation, wind) than an outdoor setting. The validity of these temperature measuring devices in a controlled environment may be more acceptable. Objective: To assess the validity and reliability of commonly used temperature devices compared with rectal temperature in individuals exercising in a controlled, high environmental temperature indoor setting and then resting in a cool environment. Design: Time series study. Setting: Laboratory environmental chamber (temperature  =  36.4 ± 1.2°C [97.5 ± 2.16°F], relative humidity  =  52%) and cool laboratory (temperature  =  approximately 23.3°C [74.0°F], relative humidity  =  40%). Patients or Other Participants: Fifteen males and 10 females. Intervention(s): Rectal, gastrointestinal, forehead, oral, aural, temporal, and axillary temperatures were measured with commonly used temperature devices. Temperature was measured before and 20 minutes after entering the environmental chamber, every 30 minutes during a 90-minute treadmill walk in the heat, and every 20 minutes during a 60-minute rest in mild conditions. Device validity and reliability were assessed with various statistical measures to compare the measurements using each device with rectal temperature. A device was considered invalid if the mean bias (average difference between rectal and device temperatures) was more than ±0.27°C (±0.50°F). Main Outcome Measure(s): Measured temperature from each device (mean and across time). Results: The following devices provided invalid estimates of rectal temperature: forehead sticker (0.29°C [0.52°F]), oral temperature using an inexpensive device (−1.13°C [−2.03°F]), temporal temperature measured according to the instruction manual (−0.87°C [−1.56°F]), temporal temperature using a modified technique (−0.63°C [−1.13°F]), oral temperature using an expensive device (−0.86°C, [−1.55°F]), aural temperature (−0.67°C, [−1.20°F]), axillary temperature using an inexpensive device (−1.25°C, [−2.24°F]), and axillary temperature using an expensive device (−0.94°F [−1.70°F]). Measurement of intestinal temperature (mean bias of −0.02°C [−0.03°F]) was the only device considered valid. Devices measured in succession (intestinal, forehead, temporal, and aural) showed acceptable reliability (all had a mean bias  =  0.09°C [0.16°F] and r ≥ 0.94]). Conclusions: Even during laboratory exercise in a controlled environment, devices used to measure forehead, temporal, oral, aural, and axillary body sites did not provide valid estimates of rectal temperature. Only intestinal temperature measurement met the criterion. Therefore, we recommend that rectal or intestinal temperature be used to assess hyperthermia in individuals exercising indoors in the heat.


2021 ◽  
Vol 17 (5) ◽  
pp. 155014772110181
Author(s):  
Wei-Ling Lin ◽  
Chun-Hung Hsieh ◽  
Tung-Shou Chen ◽  
Jeanne Chen ◽  
Jian-Le Lee ◽  
...  

Today, the most serious threat to global health is the continuous outbreak of respiratory diseases, which is called Coronavirus Disease 2019 (COVID-19). The outbreak of COVID-19 has brought severe challenges to public health and has attracted great attention from the research and medical communities. Most patients infected with COVID-19 will have fever. Therefore, the monitoring of body temperature has become one of the most important basis for pandemic prevention and testing. Among them, the measurement of body temperature is the most direct through the Forehead Thermometer, but the measurement speed is relatively slow. The cost of fast-checking body temperature measurement equipment, such as infrared body temperature detection and face recognition temperature machine, is too high, and it is difficult to build Disease Surveillance System (DSS). To solve the above-mentioned problems, the Intelligent pandemic prevention Temperature Measurement System (ITMS) and Pandemic Prevention situation Analysis System (PPAS) are proposed in this study. ITMS is used to detect body temperature. However, PPAS uses big data analysis techniques to prevent pandemics. In this study, the campus field is used as an example, in which ITMS and PPAS are used. In the research, Proof of Concept (PoC), Proof of Service (PoS), and Proof of Business (PoB) were carried out for the use of ITMS and PPAS in the campus area. From the verification, it can be seen that ITMS and PPAS can be successfully used in campus fields and are widely recognized by users. Through the verification of this research, it can be determined that ITMS and PPAS are indeed feasible and capable of dissemination. The ITMS and PPAS are expected to give full play to their functions during the spread of pandemics. All in all, the results of this research will provide a wide range of applied thinking for people who are committed to the development of science and technology.


2021 ◽  
Vol 20 ◽  
pp. 31-39
Author(s):  
Zayed Almheiri ◽  
Rawan Aleid ◽  
Sharul Sham Dol

The purpose of this research is to conduct aerodynamics study and design a hybrid drone system of fixed-wing and multi-copter. The mission of this drone is to measure human body temperature during COVID19 pandemic. The specific aim of the drone is to fly and cover larger industrial areas roughly about 50 km2 with longer flying time than the conventional drone, of about 1.5 hours. The applications of the simulation software such as XFLR5 and ANSYS have a big impact in identifying areas that need to be improved for the drone system. XFLR5 software was used to compare the characteristics of different airfoils with highest lift over drag, L/D ratio. Based on the airfoil selection, it was found that NACA 4412 airfoil produces the highest L/D ratio. The detailed geometry of the drone system includes a fuselage length of 1.9 meters and wingspan of 2 meters. Moreover, 10 sheets of solar panels were placed along the wing for sustainable flight operation to cover wider areas of mission. The structural analysis was done on ANSYS to test the elastic stress, equivalent strain, deformation, factor of safety pressure as well as lift and drag forces under various operational conditions and payloads. The landing gear was analyzed for harsh landing. ANSYS Computational Fluid Dynamics (CFD) was utilized to study the aerodynamics of the drone at different parameters such as the velocities and angles of attack during the operation. This design ensures the stability of the drone during the temperature measurement phase. The best thermal-imaging camera for such purpose would be the Vue Pro R 336, 45° radiometric drone thermal camera with a resolution of 640 x 512 pixels. This camera has the advantage of a permanent continuous out focus that give the ability of taking measurements even if there was changing on the altitude or any kind of vibrations.


Sign in / Sign up

Export Citation Format

Share Document