scholarly journals Validity and Reliability of Devices That Assess Body Temperature During Indoor Exercise in the Heat

2009 ◽  
Vol 44 (2) ◽  
pp. 124-135 ◽  
Author(s):  
Matthew S. Ganio ◽  
Christopher M. Brown ◽  
Douglas J. Casa ◽  
Shannon M. Becker ◽  
Susan W. Yeargin ◽  
...  

Abstract Context: When assessing exercise hyperthermia outdoors, the validity of certain commonly used body temperature measuring devices has been questioned. A controlled laboratory environment is generally less influenced by environmental factors (eg, ambient temperature, solar radiation, wind) than an outdoor setting. The validity of these temperature measuring devices in a controlled environment may be more acceptable. Objective: To assess the validity and reliability of commonly used temperature devices compared with rectal temperature in individuals exercising in a controlled, high environmental temperature indoor setting and then resting in a cool environment. Design: Time series study. Setting: Laboratory environmental chamber (temperature  =  36.4 ± 1.2°C [97.5 ± 2.16°F], relative humidity  =  52%) and cool laboratory (temperature  =  approximately 23.3°C [74.0°F], relative humidity  =  40%). Patients or Other Participants: Fifteen males and 10 females. Intervention(s): Rectal, gastrointestinal, forehead, oral, aural, temporal, and axillary temperatures were measured with commonly used temperature devices. Temperature was measured before and 20 minutes after entering the environmental chamber, every 30 minutes during a 90-minute treadmill walk in the heat, and every 20 minutes during a 60-minute rest in mild conditions. Device validity and reliability were assessed with various statistical measures to compare the measurements using each device with rectal temperature. A device was considered invalid if the mean bias (average difference between rectal and device temperatures) was more than ±0.27°C (±0.50°F). Main Outcome Measure(s): Measured temperature from each device (mean and across time). Results: The following devices provided invalid estimates of rectal temperature: forehead sticker (0.29°C [0.52°F]), oral temperature using an inexpensive device (−1.13°C [−2.03°F]), temporal temperature measured according to the instruction manual (−0.87°C [−1.56°F]), temporal temperature using a modified technique (−0.63°C [−1.13°F]), oral temperature using an expensive device (−0.86°C, [−1.55°F]), aural temperature (−0.67°C, [−1.20°F]), axillary temperature using an inexpensive device (−1.25°C, [−2.24°F]), and axillary temperature using an expensive device (−0.94°F [−1.70°F]). Measurement of intestinal temperature (mean bias of −0.02°C [−0.03°F]) was the only device considered valid. Devices measured in succession (intestinal, forehead, temporal, and aural) showed acceptable reliability (all had a mean bias  =  0.09°C [0.16°F] and r ≥ 0.94]). Conclusions: Even during laboratory exercise in a controlled environment, devices used to measure forehead, temporal, oral, aural, and axillary body sites did not provide valid estimates of rectal temperature. Only intestinal temperature measurement met the criterion. Therefore, we recommend that rectal or intestinal temperature be used to assess hyperthermia in individuals exercising indoors in the heat.

1983 ◽  
Vol 11 (1) ◽  
pp. 31-39 ◽  
Author(s):  
A. H. Ilsley ◽  
A. J. Rutten ◽  
W. B. Runciman

The accuracy of routine body temperature measurements, the suitability of various sites for such measurements, and the performance and practicality of various temperature measuring devices were studied. Oral and axillary temperature measurements made by the nursing staff were within 1°C of a reference value (within 0.5 °C in 67%). Both sites were suitable for routine ward temperature measurement. Mercury-in-glass thermometers are recommended for routine ward use. Electronic and disposable chemical thermometers cost more but the latter are suitable in uncooperative patients and children. Forehead skin temperature measurements using liquid crystal plastic discs were unreliable. Pulmonary artery and rectal temperature measurements were satisfactory in operating theatre and intensive care unit; however, electronic thermometers should be subjected to routine checks. The bladder temperature measuring device proved unsuitable for clinical use. When oesophagus, nasopharynx and tympanum sites are used careful placement is necessary to minimise trauma and obtain reliable measurements.


2014 ◽  
Vol 42 (01) ◽  
pp. 13-19 ◽  
Author(s):  
B. D. Kruse ◽  
R. Müller ◽  
C. Stockhaus ◽  
K. Hartmann ◽  
A. Wehner ◽  
...  

Summary Objective: Measurement of rectal temperature is the most common method and considered gold standard for obtaining body temperature in dogs. So far, no study has been performed comparing agreement between rectal and auricular measurements in a large case series. The purpose of the study was to assess agreement between rectal and auricular temperature measurement in normothermic, hypothermic, and hyperthermic dogs with consideration of different environmental conditions and ear conformations. Materials and methods: Reference values for both methods were established using 62 healthy dogs. Three hundred dogs with various diseases (220 normothermic, 32 hypothermic, 48 hyperthermic) were enrolled in this prospective study. Rectal temperature was compared to auricular temperature and differences in agreement with regard to environmental temperature, relative humidity, and different ear conformations (pendulous versus prick ears) were evaluated using Pearson’s correlation coefficient and Bland-Altman analysis. Results: Correlation between rectal and auricular temperature was significant (r: 0.892; p < 0.01). However, Bland-Altman plots showed an inacceptable variation of values (bias: 0.300 °C; limits of agreement: –0.606 to 1.206 °C). This variation was above a maximal clinical tolerance of 0.3 °C, which was established by experts’ opinion (n = 16). Relative humidity had a significant influence (p = 0.001), whereas environmental temperature did not. Conclusion: Variation between the two methods of measuring body temperature was clinically unacceptable. Clinical relevance: Although measurement of auricular temperature is fast, simple, and well tolerated, this method provides a clinically unacceptable difference to the rectal measurement.


2016 ◽  
Vol 16 (2) ◽  
pp. 131
Author(s):  
Elmy Mariana ◽  
Didik Nurul Hadi ◽  
Nur Qoim Agustin

ABSTRAK. Tujuan dari penelitian ini adalah untuk mempelajari respon fisiologi, produksi dan kualitas susu sapi perah Frisian Holstein pada akhir musim kemarau panjang di Balai Pengembangan Ternak Sapi Perah dan Hijauan Makanan Ternak (BPT-SP HMT) Cikole, Lembang, Bandung.  Penentuan sampel menggunakan metode purposive sampling. Parameter mikroklimat yang diamati antara lain adalah temperatur lingkungan, kelembaban relatif, kecepatan angin, radiasi sinar matahari dalam kandang dan Temperature-Humidity Index (THI). Respon fisiologis yang diamati meliputi suhu rektal, suhu kulit, suhu tubuh, frekuensi respirasi dan denyut jantung. Nilai rerata THI (73.93±5.51) menunjukkan sapi perah berada dalam kondisi  stress ringan. Nilai rerata dari suhu rektal, suhu kulit, suhu tubuh, frekuensi respirasi dan denyut jantung secara berurutan 37.94±0.20°C; 32.15±1.25°C; 37.13±0.32°C; 39.13 ±3.00 dan 79.74±6.19. Nilai rerata persentase bahan kering, lemak dan protein susu secara berurutan 10,19 ± 0,72, 2,14 ± 0,38 dan 2,50 ± 0,32. Temperatur lingkungan yang tinggi  mempengaruhi respon fisiologis antara lain peningkatan denyut jantung yang lebih tinggi dari normal dan kualitas susu yang lebih rendah.   (Physiological responses and milk qualities of holstein friesian during long dry season at high altitude)ABSTRACT. The objectives of this study were to evaluate physiological responses and milk qualities of dairy cows in Balai Pengembangan Ternak Sapi Perah dan Hijauan Makanan Ternak (BPT-SP HMT) Cikole West Bandung at the end of long dry season. Samples were determined by using purposive sampling method. Microclimate parameters  were included  ambient temperature, relative humidity, air velocity, solar radiation and temperature-humidity index (THI). Physiological responses consisted of rectal temperature, skin temperature, body temperature, respiration rate and pulse rate. The mean value of THI (73.93±5.51) showed that dairy cows suffered by heat stress. The mean value of rectal temperature, skin temperature, body temperature, respiration rate and pulse rate were 37.94±0.20°C; 32.15±1.25°C; 37.13±0.32°C; 39.13±3.00 and 79.74±6.19 consecutively. The average percentage value of dry matter, fat and protein content in milk were 10.19±0.72, 2.14±0.38 and 2.50±0.32. High ambient temperature and low relative humidity affected physiological responses such as pulse rate that higher than normal,  and  lower milk yield.


Sensors ◽  
2021 ◽  
Vol 21 (17) ◽  
pp. 5932
Author(s):  
Nina Verdel ◽  
Tim Podlogar ◽  
Urša Ciuha ◽  
Hans-Christer Holmberg ◽  
Tadej Debevec ◽  
...  

Monitoring core body temperature (Tc) during training and competitions, especially in a hot environment, can help enhance an athlete’s performance, as well as lower the risk for heat stroke. Accordingly, a noninvasive sensor that allows reliable monitoring of Tc would be highly beneficial in this context. One such novel non-invasive sensor was recently introduced onto the market (CORE, greenTEG, Rümlang, Switzerland), but, to our knowledge, a validation study of this device has not yet been reported. Therefore, the purpose of this study was to evaluate the validity and reliability of the CORE sensor. In Study I, 12 males were subjected to a low-to-moderate heat load by performing, on two separate occasions several days apart, two identical 60-min bouts of steady-state cycling in the laboratory at 19 °C and 30% relative humidity. In Study II, 13 males were subjected to moderate-to-high heat load by performing 90 min of cycling in the laboratory at 31 °C and 39% relative humidity. In both cases the core body temperatures indicated by the CORE sensor were compared to the corresponding values obtained using a rectal sensor (Trec). The first major finding was that the reliability of the CORE sensor is acceptable, since the mean bias between the two identical trials of exercise (0.02 °C) was not statistically significant. However, under both levels of heat load, the body temperature indicated by the CORE sensor did not agree well with Trec, with approximately 50% of all paired measurements differing by more than the predefined threshold for validity of ≤0.3 °C. In conclusion, the results obtained do not support the manufacturer’s claim that the CORE sensor provides a valid measure of core body temperature.


1967 ◽  
Vol 45 (3) ◽  
pp. 321-327 ◽  
Author(s):  
David M. Ogilvie

The effects, on the body temperature of white mice, of repeated short exposures to cold were investigated using two methods of restraint. Animals held in a flattened posture became hypothermic at room temperature, cooled more than five times as fast at −10 °C as mice that could adopt a heat-conserving posture, and continued to cool for some time after they were removed from the cold. With repeated tests, cooling at room temperature decreased, and an improvement in re warming ability was observed. In addition, with lightly restrained mice, the fall in rectal temperature during cold exposure showed a progressive decrease, a phenomenon not observed with severely restrained animals.


2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Kazuyuki Miyamoto ◽  
Keisuke Suzuki ◽  
Hirokazu Ohtaki ◽  
Motoyasu Nakamura ◽  
Hiroki Yamaga ◽  
...  

Abstract Background Heatstroke is associated with exposure to high ambient temperature (AT) and relative humidity (RH), and an increased risk of organ damage or death. Previously proposed animal models of heatstroke disregard the impact of RH. Therefore, we aimed to establish and validate an animal model of heatstroke considering RH. To validate our model, we also examined the effect of hydration and investigated gene expression of cotransporter proteins in the intestinal membranes after heat exposure. Methods Mildly dehydrated adult male C57/BL6J mice were subjected to three AT conditions (37 °C, 41 °C, or 43 °C) at RH > 99% and monitored with WetBulb globe temperature (WBGT) for 1 h. The survival rate, body weight, core body temperature, blood parameters, and histologically confirmed tissue damage were evaluated to establish a mouse heatstroke model. Then, the mice received no treatment, water, or oral rehydration solution (ORS) before and after heat exposure; subsequent organ damage was compared using our model. Thereafter, we investigated cotransporter protein gene expressions in the intestinal membranes of mice that received no treatment, water, or ORS. Results The survival rates of mice exposed to ATs of 37 °C, 41 °C, and 43 °C were 100%, 83.3%, and 0%, respectively. From this result, we excluded AT43. Mice in the AT 41 °C group appeared to be more dehydrated than those in the AT 37 °C group. WBGT in the AT 41 °C group was > 44 °C; core body temperature in this group reached 41.3 ± 0.08 °C during heat exposure and decreased to 34.0 ± 0.18 °C, returning to baseline after 8 h which showed a biphasic thermal dysregulation response. The AT 41 °C group presented with greater hepatic, renal, and musculoskeletal damage than did the other groups. The impact of ORS on recovery was greater than that of water or no treatment. The administration of ORS with heat exposure increased cotransporter gene expression in the intestines and reduced heatstroke-related damage. Conclusions We developed a novel mouse heatstroke model that considered AT and RH. We found that ORS administration improved inadequate circulation and reduced tissue injury by increasing cotransporter gene expression in the intestines.


1998 ◽  
Vol 85 (1) ◽  
pp. 204-209 ◽  
Author(s):  
John W. Castellani ◽  
Andrew J. Young ◽  
Michael N. Sawka ◽  
Kent B. Pandolf

This study examined whether serial cold-water immersions over a 10-h period would lead to fatigue of shivering and vasoconstriction. Eight men were immersed (2 h) in 20°C water three times (0700, 1100, and 1500) in 1 day (Repeat). This trial was compared with single immersions (Control) conducted at the same times of day. Before Repeat exposures at 1100 and 1500, rewarming was employed to standardize initial rectal temperature. The following observations were made in the Repeat relative to the Control trial: 1) rectal temperature was lower and heat debt was higher ( P < 0.05) at 1100; 2) metabolic heat production was lower ( P < 0.05) at 1100 and 1500; 3) subjects perceived the Repeat trial as warmer at 1100. These data suggest that repeated cold exposures may impair the ability to maintain normal body temperature because of a blunting of metabolic heat production, perhaps reflecting a fatigue mechanism. An alternative explanation is that shivering habituation develops rapidly during serially repeated cold exposures.


1993 ◽  
Vol 115 (1) ◽  
pp. 209-214 ◽  
Author(s):  
T. D. Tang ◽  
M. T. Pauken ◽  
S. M. Jeter ◽  
S. I. Abdel-Khalik

An experimental investigation has been conducted to quantify the extent by which monolayers of fatty alcohols can reduce evaporation from a deep stationary water pool within a controlled environment. Octadecanol (stearyl alcohol), C17H35–CH2–OH, was chosen as the surface film and ethanol was selected to be the spreading agent. Evaporation suppression of 60 percent was achieved at a water temperature of 25°C with an air temperature of 20°C and a relative humidity of 70 percent. The experimental techniques and data have been validated by comparing the measured evaporation rates for film-free water with earlier data published by other investigators. Data for the evaporation rates of water covered by octadecanol films were correlated as a function of vapor concentration differences between the water surface and air.


2020 ◽  
Vol 40 (2) ◽  
pp. 92-103
Author(s):  
K. O. Bello ◽  
A. E. Adiatu ◽  
M. O. Osunlakin ◽  
O. O. Oni

One hundred and thirty five 18weeks old Bovans Nera Black strain pullets were used in a 10week study to determine their heat balance and blood profile under varying stocking density in locally fabricated metal-type cage system. The cages were stocked 2, 3 and 4birds/cell. Daily ambient temperature and relative humidity of the cage and rectal temperature of the birds were taken and heat balance calculated. Record of Packed cell volume (PCV), Haemoglobin concentration (Hb), Red blood cell (RBC), White blood count (WBC) and differential of the birds were taken at beginning and end of the study for the haematological indices while blood glucose, total protein, Albumin and blood urea were taken for the bio-chemical measurements. Ambient temperature, relative humidity, and heat balance showed no significant (P>0.05) difference with cage stocking density. Cage stocking density had significant (P<0.05) effect on rectal temperature of layers. Bird stocked 3/cell recorded the least (41.14oC) rectal temperature while those stocked 4/cell recorded the highest (41.27oC). All the haematological parameters of the birds were not significantly (P>0.05) influenced by stocking density of the cage type. Bio-chemical measurements were not significantly (P>0.05) different among layers under varying stocking density of the cage except total protein (P<0.05). Layers stocked 4/cell recorded highest (5.22g/dl) total protein while those stocked 3/cell had the least value (4.37g/dl). However, the values were within the normal range recommended for healthy chicken. The study concluded that locally fabricated metal-type battery cage could be used to rear layers and stocking density of 3birds/cell is ideal without compromising the welfare of the birds.


Sign in / Sign up

Export Citation Format

Share Document