scholarly journals Application of an innovative high-throughput liquid chromatography-tandem mass spectrometry method for simultaneous analysis of 18 hazardous drugs to rule out accidental acute chemotherapy exposures in health care workers

2019 ◽  
Vol 26 (4) ◽  
pp. 794-802 ◽  
Author(s):  
Pan Shu ◽  
Ting Zhao ◽  
Bo Wen ◽  
Kari Mendelsohn-Victor ◽  
Duxin Sun ◽  
...  

Objectives Despite safe handling guidelines published by several groups, health care worker exposure to hazardous drugs continues to occur due to suboptimal engineering controls and low use of protective equipment. Simple, multi-target and specific analytical methods are needed so that acute exposures to these drugs in the workplace can be assessed rapidly. Our aim was to develop an analytical method for simultaneous detection and quantification of widely used cancer drugs to rule out accidental acute chemotherapy exposures in health care workers. Methods We examined the feasibility of alternate high-performance liquid chromatographic-tandem mass spectrometry methods to simultaneously detect eighteen chemotherapy analytes in plasma and urine. The linear concentration ranges tested during assay development were 0.1–50 ng/mL. After development of a multi-analyte assay protocol, plasma samples (n = 743) from a multi-center cluster-randomized clinical trial (n = 12 sites) of an hazardous drug educational intervention were assayed. Confirmatory assays were performed based on the individual acute-spill case-histories. Results An innovative HPLC-multiple reaction monitoring-information dependent acquisition-enhanced production ion (MRM-IDA-EPI) analytical method was developed to simultaneously detect: cytarabine, gemcitabine, dacarbazine, methotrexate, topotecan, mitomycin, pemetrexed, irinotecan, doxorubicin, vincristine, vinblastine, ifosamide, cyclophosphamide, vinorelbine, bendamustine, etoposide, docetaxel, and paclitaxel. The retention times ranged from 4 min to 13 min for the analytical run. The limit of detection (MRM-IDA-EPI) and limit of quantitation (MRM) was 0.25 ng/mL and 0.1 ng/mL, respectively for most analytes. No detectable plasma concentrations were measured at baseline, post-intervention and in cases of documented acute spills. Use of a secondary tandem mass spectrometry approach was able to successfully rule out false positive results. Conclusions Development of a sensitive high-throughput multi-analyte cancer chemotherapy assay is feasible using an MRM-IDA-EPI method. This method can be used to rapidly rule out systemic exposure to accidental acute chemotherapy spills in health care workers.

Author(s):  
Jun-Young Yang ◽  
Hyun-Kyong Ahn ◽  
Si-Won Lee ◽  
You-Jung Han ◽  
Young-Jun Oh ◽  
...  

AbstractSince the urinary concentration of 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) is a reliable biomarker of exposure to tobacco smoke, we developed a relatively simple high-throughput chromatographic method to quantify total urinary NNAL concentrations in the general population.The high-throughput analytical method was developed using ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) to identify and quantify total urinary NNAL concentrations in 10 non-smokers and 15 otherwise healthy smokers.Loss of nitric oxide atAn UPLC-MS/MS analytical method to quantify total urinary NNAL concentrations in smokers that does not require sample derivatization is presented herein. The method could be useful in clarifying the toxicities associated with human exposure to cigarette smoking. However, quantification might be adversely affected by co-eluting interfering compounds or selective ion suppression or enhancement as a result of having only one ion transition to monitor NNAL and NNAL-methyl-


2021 ◽  
pp. 130060
Author(s):  
Fabio Mazzotti ◽  
Lucia Bartella ◽  
Ines Rosita Talarico ◽  
Anna Napoli ◽  
Leonardo Di Donna

Sign in / Sign up

Export Citation Format

Share Document