Evaluation of the performance of two new generation pulse oximeters in cats at different probe positions and under the influence of vasoconstriction

2021 ◽  
pp. 1098612X2110637
Author(s):  
René Dörfelt ◽  
Julia Diels ◽  
Katrin Hartmann

Objectives The aim of this study was to compare the failure rate of two new generation pulse oximeters at different probe positions, and with and without vasoconstriction, in anaesthetised cats. Methods This prospective clinical study included 103 cats in which the new generation pulse oximeters, the Rad-5 (Masimo) and EDAN H100N (EDAN), were evaluated. Premedication consisted of the vasoconstrictive drug combination butorphanol (0.2 mg/kg IV) and dexmedetomidine (5 µg/kg IV), or butorphanol only (0.2 mg/kg IV). Pulse oximeter failure rate at the tongue was compared between both groups. Pulse oximeter failure rate was also analysed at the alternative probe positions of the lip, pinna, knee fold and toe in the butorphanol group. Student’s t-test, Wilcoxon matched pairs signed rank test, Mann−Whitney U-test, Friedman test and χ2 test were performed. A P value <0.05 was considered to be statistically significant. Results Overall failure to achieve an adequate signal was 37.6% with the Masimo and 48.0% with the EDAN pulse oximeter ( P <0.0001). At the standard probe position on the tongue, the Masimo failed in 4.5%, while the EDAN failed in 35.3% ( P <0.0001). Vasoactive premedication increased the failure rate for the Masimo from 3.8% to 5.2% ( P = 0.3414) and for the EDAN from 22.4% to 49.0% ( P <0.0001). At the alternative probe positions of the lip and knee fold, failure rates for the Masimo were lower (39.7% and 81.4%) than with the EDAN (52.6% and 94.4%; P = 0.0231 and P = 0.0005, respectively), while the Masimo failed more often at the pinna (63.5%) than the EDAN (47.4%; P = 0.0044). At the alternative probe position of the toe, the failure rate for the Masimo (32.7%) was not different from the EDAN (38.5%; P = 0.7547). Conclusions and relevance The Masimo pulse oximeter had lower signal failure rates at the standard probe position on the tongue and at 2/4 alternative probe positions. The standard probe position on the tongue had the lowest failure rate for both devices. Dexmedetomidine-induced vasoconstriction increased the failure rate for the EDAN but not for the Masimo pulse oximeter.

2008 ◽  
Vol 78 (5) ◽  
pp. 922-925 ◽  
Author(s):  
Nikolaos S. Koupis ◽  
Theodore Eliades ◽  
Athanasios E. Athanasiou

Abstract Objective: To comparatively assess clinical failure rate of brackets cured with two different photopolymerization sources after nine months of orthodontic treatment. Materials and Methods: The sample of this study comprised 30 patients who received comprehensive orthodontic treatment by means of fixed appliances. Using the same adhesive, 600 stainless steel brackets were directly bonded and light cured for 10 seconds with the light-emitting diode (LED) lamp or for 20 seconds with the conventional halogen lamp. A split-mouth design randomly alternated from patient to patient was applied. Failure rates were recorded for nine months and analyzed with Pearson χ2 test, and log-rank test at α = .05 level of significance. Results: The overall failure rate recorded with the halogen unit (3.33%) was not significantly different from the failure rate for the LED lamp (5.00%). Significantly more failures were found in boys compared with girls, in the mandibular dental arch compared with the maxillary arch, and in posterior segments compared with anterior segments. However, no significant difference was found between the right and left segments. Conclusion: Both light-curing units showed sufficiently low bond failure rates. LED curing units are an advantageous alternative to conventional halogen sources in orthodontics because they enable a reduced chair-time bonding procedure without significantly affecting bond failure rate.


1970 ◽  
Vol 29 (2) ◽  
Author(s):  
Zuber Ahamed Naqvi ◽  
Saleem Shaikh ◽  
Zameer Pasha

BACKGROUND: Bonding is an important step in fixed orthodontic mechanotherapy. Many new materials introduced an adhesive for bonding. This study was designed to evaluate the clinical bond failure rate of orthodontic brackets bonded with green glue: two way color changes adhesive and transbond XT adhesive paste.METHODS: Eighteen male patients with a mean age of 16 years were included in the study. Convenience sampling technique was used to select the sample for this study. The split-mouth design was used to bond 360 brackets by one operator and both adhesives were used in each patient. Bond failure rates were estimated with respect to bonding procedure, dental arch, tooth type (incisor, canine, and premolar). The results were evaluated using the chisquare test. Kaplan – Meier analysis and the log rank test were used to estimate the survival rate of the brackets. Bracket failure rates for each system were analyzed, and failure causes as reported by the patients and the quadrant of each tooth in which bracketsfailed were recorded.RESULTS: The bond failure rate was 5.00% and 4.44% for green gloo and transbond XT group. No significant difference was found in the bond failure rate between transbond XT and Green gloo group. No significant difference was found in the bond failure rate between the two groups, in relation to right and left side and the type of teeth.CONCLUSION: Green gloo adhesive can be effectively used to bond orthodontic brackets.


2012 ◽  
Vol 26 (2) ◽  
pp. 172-180 ◽  
Author(s):  
Anne C. van der Eijk ◽  
Sandra Horsch ◽  
Paul H. C. Eilers ◽  
Jenny Dankelman ◽  
Bert J. Smit

2021 ◽  
Vol 8 ◽  
Author(s):  
Jan Nixdorff ◽  
Yury Zablotski ◽  
Katrin Hartmann ◽  
Rene Dörfelt

Objectives: The tongue is the standard site for placement of a pulse oximeter probe but is difficult to access during certain procedures such as dental and ophthalmic procedures and computerized tomography of the head. The aim of this study was to evaluate the performance of a new-generation reflectance pulse oximeter using the tail and tibia as sites for probe attachment.Materials and Methods: A total of 100 client-owned dogs that underwent anesthesia for various reasons were premedicated with butorphanol (n = 50; 0.2 mg/kg; group BUT) or butorphanol and dexmedetomidine (n = 50; 5 μg/kg; group DEX), administered intravenously. Anesthesia was induced with propofol and maintained with sevoflurane. A transmittance pulse oximeter probe was placed on the tongue and served as the reference standard. A reflectance probe was randomly placed on the tail base or the proximal tibia, and the position changed after testing. Signals from three consecutive measurements were obtained at each position. Failure was defined as “no signal,” “low signal,” or a pulse difference &gt;10/min compared with the ECG heart rate. Data were analyzed using chi-square test, Wilcoxon matched-pair signed-rank test, and Bland-Altman analysis. P &lt; 0.05 was considered significant.Results: In both groups (BUT and DEX), failure rate was higher when the tibia and tail were used as probe sites compared with the tongue. In both groups, the failure rate was higher for the tibia than for the tail. Dexmedetomidine-induced vasoconstriction increased failure rate at all probe positions.Clinical Significance: The tail base, but not the tibia, is an acceptable position for reflectance pulse oximeter probes in dogs. The tongue remains the probe site of choice, if accessible.


2005 ◽  
Vol 14 (1) ◽  
pp. 26-37 ◽  
Author(s):  
Karen K. Giuliano ◽  
Thomas L. Higgins

• Objective To review the published, peer-reviewed studies to date on use of the new-generation pulse oximeters, which are manufactured with algorithms to filter out patients’ body motions, and describe the application of new-generation pulse oximetry in clinical practice in critical care. • Methods MEDLINE was used to locate appropriate articles on pulse oximetry for the years 1995 to 2003. Each article was examined for scientific merit, content, and applicability to clinical practice. • Results A total of 17 relevant articles on the clinical performance of the new-generation pulse oximeters were reviewed, and the data were organized into a table. • Conclusions The combination of studies done in both clinical and laboratory settings did not provide any strong and convincing evidence that the performance of any single new-generation device was superior to that of any other new-generation device. However, the clinical performance of all the new-generation pulse oximetry devices was better than that of earlier devices.