Surgical outcomes of modified capsular tension ring and intraocular lens implantation in Marfan syndrome with ectopia lentis

2021 ◽  
pp. 112067212110128
Author(s):  
Zexu Chen ◽  
Min Zhang ◽  
Michael Deng ◽  
Tianhui Chen ◽  
Jiahui Chen ◽  
...  

Objective: To evaluate surgical outcomes of modified capsular tension ring (MCTR) and intraocular lens (IOL) implantation in eyes of Marfan syndrome (MFS). Methods: This retrospective case series included MFS patients receiving MCTR transscleral fixation and IOL in-the-bag implantation. The MCTR was sutured to the sclera through a sulcus by 9–0 polypropylene with the modified knotless Z-suture technique. Main outcomes were visual acuity and postoperative complications. Results: A total of 109 MFS patients (187 eyes) had the surgery. Patients were 15.47 ± 14.36 years old and followed up for 10.07 ± 8.99 months. MCTR and IOL implantations were performed in 174 eyes (93.05%). The postoperative BCVA (LogMAR) was 0.24 ± 0.24 (1 month), 0.26 ± 0.20 (3 months), 0.22 ± 0.20 (6 months), 0.20 ± 0.19 (12 months) and 0.25 ± 0.32 (over 12 months), which was significantly better than preoperatively (0.63 ± 0.35) ( p < 0.001). Major complications included posterior capsular opacification (PCO) in 41 eyes (23.56%) and decentered anterior capsular opacification (ACO) in 15 eyes (8.62%). The mean occurrence time was 9.44 ± 7.08 and 8.87 ± 15.08 months respectively. Other complications included transient intraocular pressure elevation in seven eyes (4.02%), retinal detachment in two eyes (1.15%), cystoid macula edema in one eye (0.57%), and endophthalmitis in one eye (0.57%). No eye had suture breakage or IOL dislocation. Conclusions: The visual improvement is significant in eyes of MFS undergoing MCTR transscleral fixation and IOL in-the-bag implantation. The long-term monitoring of complications is warranted, especially in the first-two years.

2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Ke Lin ◽  
Zhixiang Hu ◽  
Zhong Lin ◽  
Tianyu Chen ◽  
Yongping Tang ◽  
...  

Abstract Background To report a new technique for iris capture of the posterior chamber intraocular lens (IOL) implanted in patients with a posterior capsule defect. Methods In this retrospective case series, a rectangular loop ciliary body suture technique was performed to rectify iris capture. The suture passes between the IOL and iris in a direction perpendicular to the iris edge capturing the IOL. Results A total of three IOLs with iris capture underwent a rectangular loop suture technique. No recapture was observed postoperatively. In one case, large astigmatism appeared after the surgery but recovered at 1 month post operation. No further complications were found. Conclusions The rectangular loop suture technique is an effective, convenient, and minimally invasive method for iris capture of the IOL.


2018 ◽  
Vol 16 (2) ◽  
pp. 124-133
Author(s):  
Rosemary Tomy ◽  
Rajkumar Maheshwari ◽  
Ansa Parveen Kunhu Muhammed ◽  
Venkataramana Kalikivayi ◽  
Sajeev Cherian Jacob

Purpose: To assess the indications and visual outcome of eyes undergoing posterior iris fixated intraocular lens (IFIOL) implantation for aphakia, to identify reasons for poor visual outcome, and report occurrence of complications. Methods: In this retrospective case series study, all cases of posterior IFIOL fixation performed over a 30-month period were identified retrospectively. Preoperative and postoperative evaluations comprised objective and subjective refraction, best corrected visual acuity (BCVA), slit lamp biomicroscopy, applanation tonometry, and dilated fundus examination. Results: Fifty-six eyes of 56 patients were analyzed. Mean age was 60.55 ± 17.2 years. The most common indication for IFIOL implantation was surgical aphakia following complicated cataract surgery (n = 33; 58.9%) followed by trauma (n = 10; 17.9%), dropped nucleus/IOL during primary surgery (n = 6; 10.7%), and subluxated/dislocated lens-induced glaucomas (n = 5; 8.9%). BCVA better than or equal to their preoperative BCVA was achieved in 96.43% patients. The surgical aphakia and paediatric/adolescent groups had the best visual results while the dropped nucleus/IOL group and subluxated lens-induced glaucoma groups fared poorly. On the long-term follow-up visit, the most common complication noted was pigment dusting on the corneal endothelium (65.7%). Conclusion: The long-term results suggest that posterior IFIOL implantation is a safe and effective method for correction of aphakia and can be used for a wide range of indications in eyes without adequate capsule support. It may be considered an easier and faster alternative with minimal manipulation to anterior segment structures in paediatric and post-traumatic aphakic eyes.


2020 ◽  
pp. 107110072097128
Author(s):  
Kyung Rae Ko ◽  
Jong Sup Shim ◽  
Jiwon Kang ◽  
Jaesung Park

Background: We aimed to report surgical outcomes and analyze prognostic factors of medial toe excision for polysyndactyly of the fifth toe. Methods: We reviewed the details of 139 consecutive patients who underwent surgery for postaxial polydactyly of the foot from 2009 to 2018. Among these, 83 patients (90 feet) with polysyndactyly of the fifth toe, treated by medial toe excision (between the duplicated toes) and reconstruction of the fourth web space using a dorsal rectangular flap, were included. The toe alignment and stability were restored by chondroplasty and soft tissue balancing without an osteotomy. A full-thickness skin graft was performed in 52 feet. The mean age at surgery was 27.1 ± 17.5 months and the mean duration of follow-up was 42.8 ± 24.9 months. Results: At the last follow-up, a relatively small size of the reconstructed toe was observed in 19 feet (19/90, 21.1%). Proximal duplication level (metatarsal or proximal phalanx type) and preoperative hypoplasia of the remaining toe were related to the small postoperative size. Valgus deformity of the remaining toe was observed in 2 feet (2/90, 2.2%). We observed 17 cases with delayed healing or early postoperative wound infection. Among these, 7 cases (7/90, 7.8%) showed postoperative thickening or advancement of the web, which was not observed in cases without wound problems. No cases had functional disturbance or pain. Conclusion: The overall surgical outcomes were satisfactory without an osteotomy. Patients with a proximal duplication level or preoperative hypoplasia of the remaining toe should be informed of its possible small size postoperatively. Levels of Evidence: Level IV, retrospective case series.


2020 ◽  
pp. 112067212096203
Author(s):  
David Carmona-González ◽  
Alfredo Castillo-Gómez ◽  
Carlos Palomino-Bautista ◽  
Marta Romero-Domínguez ◽  
María Ángeles Gutiérrez-Moreno

Purpose To compare the accuracy of 11 intraocular lens (IOL) power calculation formulas (SRK-T, Hoffer Q, Holladay I, Haigis, Holladay II, Olsen, Barrett Universal II, Hill-RBF, Ladas Super formula, EVO and Kane). Setting Private university hospital (QuironSalud, Madrid, Spain). Design Retrospective case series Methods Data were compiled from 481 eyes of 481 patients who had undergone uneventful cataract surgery with IOL insertion. Preoperative biometric measurements were made using an IOL Master® 700. Respective ULIB IOL constants ( http://ocusoft.de/ulib/c1.htm ) for each of 4 IOL models implanted were used to calculate the predictive refractive outcome for each formula. This was compared with the actual refractive outcome determined 3 months postoperatively. The primary outcome was mean absolute prediction error (MAE). The study sample was divided according to axial length (AL) into three groups of eyes: short (⩽22.00 mm), normal (22.00–25.00 mm) and long (⩾25.00 mm). Results The Barrett Universal II and Haigis formulas yielded the lowest MAEs over the entire AL range ( p < .01, except EVO) as well as in the long ( p < .01, all formulas) and normal ( p < .01, except Haigis, Holladay II, Olsen and LSF) eyes. In the short eyes, the lower MAEs were provided by Haigis and EVO ( p < .01 except Hoffer Q, SRK/T and Holladay I). Conclusions Barrett Universal II was the most accurate for IOL power calculation in the normal and long eyes. For short eyes, the formulas Haigis and EVO seem best at predicting refractive outcomes.


2018 ◽  
Vol 2018 ◽  
pp. 1-4 ◽  
Author(s):  
Takayuki Baba ◽  
Tomohiro Nizawa ◽  
Toshiyuki Oshitari ◽  
Shuichi Yamamoto

Purpose. To compare the visual and surgical outcomes after a reuse or a replacement of a dislocated in-the-bag intraocular lens (IOL). Methods. This was a retrospective, nonrandomized case series at a single ophthalmological institution. Cases with an in-the-bag dislocation of an IOL were treated by pars plana vitrectomy and the reuse or the replacement of the IOL. The lens was held by intrascleral fixation of the haptics of the IOL under both conditions. The same dislocated IOL was reused in 6 eyes (group A) or it was replaced with another IOL in the other 9 eyes (group B). The pre- and postoperative parameters analyzed included the visual acuity, refractive error, corneal endothelial cell density, and intraocular pressure (IOP). Results. There was no significant difference between the two groups in the postoperative visual acuity (P=0.388), refractive error (P=0.955), IOP (P=0.529), and endothelial cell loss (P=0.940). A breakage or a tilting of the IOL was observed and required replacement in three eyes in the reuse group (P=0.044). Conclusions. Half of the cases with reused in-the-bag dislocated IOL had a breakage or a tilting of the IOL. The replacement of the in-the-bag dislocated IOL is better than the reuse of the IOL with intrascleral haptics fixation.


2019 ◽  
Author(s):  
Carlos Alberto Idrobo ◽  
Gisella Santaella ◽  
Ángela María Gutiérrez

Abstract ABSTRACT Background: To determine the accuracy of the T2 formula as applied to highly myopic eyes, to compare the T2 formula to the SRK/T and Holladay 1 formulas, and to describe possible ways to improve the estimation of corneal height and prediction error in two settings, the Hadassah Hospital, Ophthalmology Department, Jerusalem, Israel and Clínica Barraquer, Bogotá, Colombia. Methods: In this retrospective case series , optical biometer measurements were taken for 63 highly myopic patients (> 25 mm ) undergoing uneventful crystalline lens phacoemulsification and insertion of an acrylic intraocular lens. Prediction errors were obtained, with estimations of ± 0.50 D, ± 1.00 D, and greater than ± 2.00 D. A method to improve the corneal height calculation is described. Results: The SRK/T formula (mean absolute error [MAE] = 0.418; median absolute error [MedAE] = 0.352) was the most accurate, followed by the T2 (MAE = 0.435; MedAE = 0.381) and Holladay 1 (MAE = 0.455; MedAE = 0.389) formulas. Both the SRK/T and T2 formulas overestimated corneal height, but values were higher with the T2 formula. Corneal height was more precisely estimated using an alternative method that, when combined with axial length optimization, resulted in lower MAE (0.425) and MedAE (0.365) values than when applying the T2 formula alone. Conclusions: The T2 formula seems to be less accurate than the SRK/T formula in highly myopic eyes. An improved corneal height estimation method is described for the the T2 formula. Key words: T2 formula, high myopia, corneal height estimation, cataract surgery, intraocular lens calculation .


2020 ◽  
pp. 247412642094660
Author(s):  
Peter J. Belin ◽  
Jang H. Kim ◽  
Ahmed Sheikh ◽  
Jules Winokur ◽  
David Rhee ◽  
...  

Purpose: Postoperative hydrophilic intraocular lens opacification can lead to decreased vision and may require intraocular lens exchange. This study aims to identify the incidence of scleral-fixated Akreos AO60’s (Bausch + Lomb) lens opacification and risk factors for this phenomenon. Methods: This is a retrospective case series of all patients who underwent scleral-fixated Akreos AO60 lens at our institution between January 1, 2015 and December 31, 2019. The following data were recorded: age, sex, medical history, indication for Akreos AO60 implantation, laterality, ocular history, previous ocular surgical procedures, subsequent intraocular surgical procedures after the Akreos implantation, lens opacification, visual significance of opacification, and Akreos explantation. Intraoperative and postoperative complications were recorded. Main outcome measures were the overall incidence of Akreos lens opacification as well as the incidence of these eyes undergoing subsequent intraocular surgery. Results: A total of 262 eyes of 257 patients underwent Akreos lens implantation. Overall, 2% (5 of 262) developed lens opacification. Two patients had Descemet stripping automated endothelial keratoplasty (DSAEK) concurrently with Akreos implantation. One patient underwent subsequent Baerveldt glaucoma implantation and DSAEK. The fourth patient had vitrectomy with sulfur hexafluoride gas followed by DSAEK. This represents a 25% (4 of 16) opacification rate among all patients who underwent DSAEK ( P ≤ .01, Fisher exact test). One patient developed opacification after undergoing 2 vitrectomies for retinal detachment in the absence of DSAEK. Conclusions: Akreos lens opacification can be visually significant and may occur after a retinal or corneal procedure that involves the use of intraocular gas or air.


2016 ◽  
Vol 7 (3) ◽  
pp. 496-504 ◽  
Author(s):  
John S.M. Chang ◽  
Jack C.M. Ng ◽  
Vincent K.C. Chan ◽  
Antony K.P. Law

Purpose: To report visual outcomes and complications after cataract surgery in nanophthalmic eyes with a phacoemulsification system using the active fluidics control strategy. Methods: This is a retrospective case series. All eyes with an axial length of less than 20 mm that underwent cataract surgery or refractive lens exchange using the Centurion Vision System (Alcon Laboratories Inc.) in Hong Kong Sanatorium and Hospital were evaluated. The visual acuity and intraoperative and postoperative complications were reported. Prior approval from the Hospital Research Committee has been granted. Results: Five eyes of 3 patients were included. The mean follow-up period was 10.2 ± 5.3 months (range, 4–18). Two eyes (40%) had a one-line loss of corrected distance visual acuity. No uveal effusion and posterior capsular tear developed. An optic crack and haptic breakage in the intraocular lens developed in 1 eye (20%) and 2 eyes (40%), respectively. Additional surgeries to treat high postoperative intraocular pressure were required in 1 eye (20%). Conclusion: The use of a new phacoemulsification system, which actively monitors and maintains the intraoperative pressure, facilitated anterior chamber stability during cataract surgery in nanophthalmic eyes. This minimized the risk of major complications related to unstable anterior chambers such as uveal effusion and posterior capsular tear. Development of intraoperative crack/breakage in a high-power intraocular lens was common.


Sign in / Sign up

Export Citation Format

Share Document