Arteriovenous fistula and pre-surgery mapping: Potential role of physical exercise on endothelial function

2019 ◽  
Vol 20 (6) ◽  
pp. 652-658 ◽  
Author(s):  
Giulio Distefano ◽  
Luca Zanoli ◽  
Antonio Basile ◽  
Pasquale Fatuzzo ◽  
Antonio Granata

Background: The success of the construction of an arteriovenous fistula for haemodialysis is related to the vascular function of the vessels involved in the anastomosis, with particular reference to radial artery distensibility after reactive hyperaemia test and to the fall of resistance index. Only few studies have evaluated the impact of exercise protocols on the endothelial and morphological characteristics of the vessels of the upper limb with inconclusive results. In this pilot longitudinal study, we aimed to evaluate the impact of a standardized exercise protocol on the haemodynamic and resistive index of the arteries of the upper limb of uraemic patients. Methods: A total of 17 uraemic patients planned to construct arteriovenous fistula at the distal third of the forearm were enrolled and followed up for 30 days. All patients performed repeated handgrips for 30 min/day. The arterial parameters were detected before and after an ischaemic stress of 5 min and radial and brachial artery flow-mediated dilation was evaluated as well as radial artery resistance index. Results: Pre-exercise measurements of radial artery diameter and resistance index and brachial artery diameter were not modified by 30 days hand physical exercise, whereas the post-exercise haemodynamic were improved. Consequently, flow-mediated dilation of the radial artery was improved (21% ± 14% vs 30% ± 19%; p = 0.03) and resistance index of the radial artery was reduced ( p = 0.02). Conclusion: Exercise has beneficial effects on endothelial function of the radial artery by resistive index and, potentially, on the outcome of the arteriovenous fistula. Further studies with larger sample size are needed to confirm our preliminary data.

2014 ◽  
Vol 39 (2) ◽  
pp. 145-151 ◽  
Author(s):  
Tim H.A. Schreuder ◽  
Thijs M.H. Eijsvogels ◽  
Arno Greyling ◽  
Richard Draijer ◽  
Maria T.E. Hopman ◽  
...  

Tea consumption is associated with reduced cardiovascular risk. Previous studies found that tea flavonoids work through direct effects on the vasculature, leading to dose-dependent improvements in endothelial function. Cardioprotective effects of regular tea consumption may relate to the prevention of endothelial ischaemia–reperfusion (IR) injury. Therefore, we examined the effect of black tea consumption on endothelial function and the ability of tea to prevent IR injury. In a randomized, crossover study, 20 healthy subjects underwent 7 days of tea consumption (3 cups per day) or abstinence from tea. We examined brachial artery (BA) endothelial function via flow-mediated dilation (FMD), using high resolution echo-Doppler, before and 90 min after tea or hot water consumption. Subsequently, we followed a 20-min ischaemia and 20-min reperfusion protocol of the BA after which we measured FMD to examine the potential of tea consumption to protect against IR injury. Tea consumption resulted in an immediate increase in FMD% (pre-consumption: 5.8 ± 2.5; post-consumption: 7.2 ± 3.2; p < 0.01), whilst no such change occurred after ingestion of hot water. The IR protocol resulted in a significant decrease in FMD (p < 0.005), which was also present after tea consumption (p < 0.001). This decline was accompanied by an increase in the post-IR baseline diameter. In conclusion, these data indicate that tea ingestion improves BA FMD. However, the impact of the IR protocol on FMD was not influenced by tea consumption. Therefore, the cardioprotective association of tea ingestion relates to a direct effect of tea on the endothelium in humans in vivo.


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
Stella Brilli ◽  
Dimitris Tousoulis ◽  
Charalambos Antoniades ◽  
George Hatzis ◽  
Nikos Ioakeimidis ◽  
...  

Background: Marfan syndrome is characterised by high risk of aortic dissections and increased cardiovascular risk. However, the impact of Marfan syndrome on endothelial function and arterial stiffness is unclear, while the role of matrix metalloproteinases is unknown. We examined the impact of Marfan syndrome on the elastic properties of the arterial tree, and vascular endothelial function, and we evaluated the potential role of matrix metalloproteinases in these effects. Methods: The study population consisted of 17 subjects with Marfan syndrome, aged 26.6±2.3 years old, with BMI 20.5±1.03Kg/m2 and 22 healthy individuals matched for gender, age (26.4±0.78 years old, p=NS) and BMI (22.4±0.86 Kg/m2). Arterial stiffness was evaluated by measuring carotid-femoral pulse wave velocity (PWV), while augmentation pressure and augmentation index (AIx) were also determined, as measures of arterial wave reflections. Endothelial function was evaluated by determining flow mediated dilation (FMD) in the brachial artery while matrix metalloproteinase 9 (MMP-9) levels were determined by ELISA. Results: Patients with Marfan syndrome had significantly lower pulse pressure in the radial artery (41.0±1.07mmHg) compared to controls (51.3±4.4mmHg). In addition, patients had higher AIx (17.6±2.4%) and augmentation pressure (5.44±0.65mmHg) compared to controls (7.72±3.43% and 2.41±1.14mmHg respectively, p<0.05 for both). However, the difference in PWV between patients and controls did not reach statistical significance (6.33±0.33 vs 5.96±0.23m/s respectively, p=NS). Patients with Marfan syndrome had lower FMD (2.05±1.13%) and higher plasma MMP-9 (827±70ng/ml) compared to controls (6.8±2.3% p<0.05 and 326±50ng/ml, p<0.01). Conclusions: Marfan syndrome is associated with increased MMP-9 levels, as well as with elevated augmentation index and augmentation pressure compared to healthy individuals, matched for age, gender and body mass index. Moreover, flow-mediated dilation is also impaired in these subjects. These findings suggest that Marfan syndrome directly affects the elastic properties and endothelial function of the arterial tree, with matrix metalloproteinases being important mediators in the pathophysiology of this syndrome.


2020 ◽  
Vol 41 (33) ◽  
pp. 3144-3152 ◽  
Author(s):  
Boris Schnorbus ◽  
Andreas Daiber ◽  
Kerstin Jurk ◽  
Silke Warnke ◽  
Jochem Koenig ◽  
...  

Abstract Aims In a randomized, parallel, blinded study, we investigate the impact of clopidogrel, prasugrel, or ticagrelor on peripheral endothelial function in patients undergoing stenting for an acute coronary syndrome. Methods and results The primary endpoint of the study was the change in endothelium-dependent flow-mediated dilation (FMD) following stenting. A total of 90 patients (age 62 ± 9 years, 81 males, 22 diabetics, 49 non-ST elevation myocardial infarctions) were enrolled. There were no significant differences among groups in any clinical parameter. Acutely before stenting, all three drugs improved FMD without differences between groups (P = 0.73). Stenting blunted FMD in the clopidogrel and ticagrelor group (both P &lt; 0.01), but not in the prasugrel group. During follow-up, prasugrel was superior to clopidogrel [mean difference 2.13, 95% confidence interval (CI) 0.68–3.58; P = 0.0047] and ticagrelor (mean difference 1.57, 95% CI 0.31–2.83; P = 0.0155), but this difference was limited to patients who received the study therapy 2 h before stenting. Ticagrelor was not significantly superior to clopidogrel (mean difference 0.55, 95% CI −0.73 to 1.82; P = 0.39). No significant differences were seen among groups for low-flow-mediated dilation. Plasma interleukin (IL)-6 (P = 0.02 and P = 0.01, respectively) and platelet aggregation reactivity in response to adenosine diphosphate (P = 0.002 and P = 0.035) were lower in the prasugrel compared to clopidogrel and ticagrelor group. Conclusion As compared to ticagrelor and clopidogrel, therapy with prasugrel in patients undergoing stenting for an acute coronary syndrome is associated with improved endothelial function, stronger platelet inhibition, and reduced IL-6 levels, all of which may have prognostic implications. This effect was lost in patients who received the study medication immediately after stenting. EUDRACT-No 2011-005305-73


Author(s):  
Nidhi Pandey ◽  
Poonam Goel ◽  
Anita Malhotra ◽  
Reeti Mehra ◽  
Navjot Kaur

Background: The objective of the study was to assess vascular function in normal pregnant women and women with gestational diabetes and to study its temporal relationship with gestational age at 24-28-week POG and at 36-38-week POG and changes in FMD in postpartum period.Methods: Assessment of vascular function was done at 24-28-week POG, 36-38-week POG and at 6-12-week postpartum by flow mediated dilation of brachial artery in 37 healthy pregnant women and 37 pregnant women with GDM.Results: In GDM group mean FMD at 24-28 weeks of POG, at 36-38 weeks POG was lower as compared to the control group (11.225±6.20,8.464±6.09 versus 14.49±5.21, 10.898±4.12) although the difference in mean FMD in two groups was not statistically significant. It was found that the decrease in FMD at 36-38-week POG as compared to 24-28 weeks POG was statistically significant in both the groups (p<0.001).Conclusions: This study revealed that when endothelial function as assessed by FMD was compared at different period of gestation, the mean decrease in FMD at 36-38-week POG as compared to 24-28-week POG and 6-week post-partum was statistically significant in patients with GDM and as well as the control group, however this trend of change was same in both the groups and was not statistically significant when compared between the two group (GDM versus control). A negative correlation of FMD was found with BMI, and HBA1c, that was stronger in GDM group.


2020 ◽  
pp. 112972982092393
Author(s):  
Ya-wen Mo ◽  
Chun-yan Sun ◽  
Li Song ◽  
Li-fang Zhou ◽  
Ting-ting Zhuang ◽  
...  

Background: The important effect of regular blood flow surveillance on arteriovenous fistula maintenance is emphasized. The ultrasonic dilution technique for blood flow surveillance can be performed during hemodialysis, but there are some limitations. Blood flow is traditionally measured by duplex Doppler ultrasound during the nondialysis period. However, the surveillance workload for arteriovenous fistula has increased with the rapid increase in the hemodialysis population size. Efficient methods for blood flow surveillance during hemodialysis are needed. Methods: Eighty-four hemodialysis patients with a forearm radiocephalic arteriovenous fistula were enrolled in this cross-sectional study. Each received blood flow measurements using ultrasonic dilution technique and duplex Doppler ultrasound during hemodialysis. Duplex Doppler ultrasound measurements included the blood flow of the brachial artery and radial artery. The correlations between these variables were analyzed. Results: The correlation coefficients ( r) between flow measured by ultrasonic dilution technique and brachial artery flow measured by duplex Doppler ultrasound, between flow measured by ultrasonic dilution technique and radial artery flow measured by duplex Doppler ultrasound, and between brachial artery flow and radial artery flow measured by duplex Doppler ultrasound were 0.724, 0.784, and 0.749, respectively (all p < 0.001). Conclusion: Blood flow measured by ultrasonic dilution technique was positively correlated with blood flow measured by duplex Doppler ultrasound during hemodialysis, suggesting that duplex Doppler ultrasound can be used to monitor the trends in the blood flow of the brachial artery and radial artery for timely intervention to improve patency during hemodialysis.


2014 ◽  
Vol 03 (04) ◽  
pp. 225-228
Author(s):  
Sankaran PK ◽  
Gunapriya Raghunath ◽  
Sathyan R. ◽  

AbstractDuring routine dissection of upper limb, a variation in the origin of radial artery was observed in a female cadaver of about 60 years. The radial artery is usually a smaller terminal branch of the brachial artery in the forearm. On the right side of the cadaver the radial artery was found to originate from second part of the axillary artery, whereas on the left side the origin of radial artery was found to be normal. This variant of radial artery has been rarely documented in literature. Accurate anatomy of radial artery and its variations have definite diagnostic, interventional, and surgical significance.


2004 ◽  
Vol 287 (1) ◽  
pp. H374-H380 ◽  
Author(s):  
Patricia C. E. de Groot ◽  
Fleur Poelkens ◽  
Miriam Kooijman ◽  
Maria T. E. Hopman

The aim of the study was to assess endothelial function, measured by flow-mediated dilation (FMD), in an inactive extremity (leg) and chronically active extremity (arm) within one subject. Eleven male spinal cord-injured (SCI) individuals and eleven male controls (C) were included. Echo Doppler measurements were performed to measure FMD responses after 10 and 5 min of arterial occlusion of the leg (superficial femoral artery, SFA) and the arm (brachial artery, BA), respectively. A nitroglycerine spray was administered to determine the endothelium independent vasodilatation in the SFA. In the SFA, relative changes in FMD were significantly enhanced in SCI compared with C (SCI: 14.1 ± 1.3%; C: 9.2 ± 2.3%), whereas no differences were found in the BA (SCI: 12.5 ± 2.9%; C: 14.2 ± 3.3%). Because the FMD response is directly proportional to the magnitude of the stimulus, the FMD response was also expressed relative to the shear rate. No differences between the groups were found for the FMD-to-shear rate ratio in the SFA (SCI:0.061 ± 0.023%/s−1; C: 0.049 ± 0.024%/s−1), whereas the FMD-to-shear rate ratio was significantly decreased in the BA of SCI individuals (SCI: 0.037 ± 0.01%/s−1; C: 0.061 ± 0.027%/s−1). The relative dilatory response to nitroglycerine did not differ between the groups. (SCI: 15.6 ± 2.0%; C: 13.4 ± 2.3%). In conclusion, our results indicate that SCI individuals have a preserved endothelial function in the inactive legs and possibly an attenuated endothelial function in the active arms compared with controls.


2010 ◽  
Vol 39 (3) ◽  
pp. 222-231 ◽  
Author(s):  
Denise C. Cooper ◽  
Milos S. Milic ◽  
Paul J. Mills ◽  
Wayne A. Bardwell ◽  
Michael G. Ziegler ◽  
...  

2014 ◽  
Vol 39 (8) ◽  
pp. 927-936 ◽  
Author(s):  
Ingrid C. Szijgyarto ◽  
Veronica J. Poitras ◽  
Brendon J. Gurd ◽  
Kyra E. Pyke

Exercise elevates conduit artery shear stress and stimulates flow-mediated dilation (FMD). However, little is known regarding the impact of acute psychological and physical stress on this response. The purpose of this study was to examine the impact of the Trier Social Stress Test (TSST (speech and arithmetic tasks)) and a cold pressor test (CPT) with and without social evaluation (SE) on exercise-induced brachial artery FMD (EX-FMD). A total of 59 healthy male subjects were randomly assigned to 1 of 3 conditions: TSST, CPT, or CPT with SE. During 6 min of handgrip exercise, brachial artery EX-FMD was assessed before and 15 and 35 min poststress with echo and Doppler ultrasound. Shear stress was estimated as shear rate, calculated as brachial artery mean blood velocity/brachial artery diameter. Results are means ± SD. All conditions elicited significant physiological stress responses. Salivary cortisol increased from 4.6 ± 2.4 nmol/L to 10.0 ± 5.0 nmol/L (p < 0.001; condition effect: p = 0.292). Mean arterial pressure increased from 98.6 ± 12.1 mm Hg to 131.9 ± 18.7 mm Hg (p < 0.001; condition effect: p = 0.664). Exercise shear rate did not differ between conditions (p = 0.592), although it was modestly lower poststress (prestress: 72.3 ± 4.5 s−1; 15 min poststress: 70.8 ± 5.4 s−1; 35 min poststress: 70.6 ± 6.1 s−1; trial effect: p = 0.011). EX-FMD increased from prestress to 15 min poststress in all conditions (prestress: 6.2% ± 2.8%; 15 min poststress: 7.9% ± 3.2%; 35 min poststress: 6.6% ± 2.9%; trial effect: p < 0.001; condition effect: p = 0.611). In conclusion, all conditions elicited similar stress responses that transiently enhanced EX-FMD. This response may help to support muscle perfusion during stress.


Sign in / Sign up

Export Citation Format

Share Document