Experimental study of precast beam-to-column joints with steel connectors under cyclic loading

2020 ◽  
Vol 23 (13) ◽  
pp. 2822-2834
Author(s):  
Xian Rong ◽  
Hongwei Yang ◽  
Jianxin Zhang

This article investigated the seismic performance of a new type of precast concrete beam-to-column joint with a steel connector for easy construction. Five interior beam-to-column joints, four precast concrete specimens, and one monolithic joint were tested under reversed cyclic loading. The main variables were the embedded H-beam length, web plate or stiffening rib usage, and concrete usage in the connection part. The load–displacement hysteresis curves were recorded during the test, and the behavior was investigated based on displacement ductility, deformability, skeleton curves, stiffness degradation, and energy dissipation capacity. The results showed that the proposed beam-to-column joint with the web plate in the steel connector exhibited satisfactory behavior in terms of ductility, load capacity, and energy dissipation capacity under reversed cyclic loading, and the performance was ductile because of the yielding of the web plate. Therefore, the proposed joint with the web plate could be used in high seismic regions. The proposed joint without the web plate exhibited similar behavior to the monolithic specimen, indicating that this joint could be used in low or moderate seismic zones. Furthermore, the utilization of the web plate was vital to the performance of this system.

2020 ◽  
Vol 17 (9) ◽  
pp. 3934-3939
Author(s):  
B. Nambiyanna ◽  
M. N. Chandan ◽  
R. Prabhakara

Beam-Column Joint plays an imperative part in the seismic enactment of Reinforced concrete moment resisting frame. The response of the structure under the earthquake loads mainly depends on the behavior and performance of the Beam-Column Joint (BCJ). An experimental investigation on exterior reinforced beam-column joints done using steel fibre reinforced self-compacting concrete subjected to reversed cyclic loading is presented in this investigation. The attempt has been made to demonstrate the influence of steel fibers reinforced self-compacting concrete (SCC). Three exterior beam-column joints having the same geometry were cast and tested through reversed cyclic load using displacement-controlled mechanism. All three specimens are designed adequately in accordance with IS 13920:2016 code. The hysteresis loop, ductility factor, stiffness degradation, energy dissipation characteristics, and damage propagation are considered to quantify the response of joint specimens. The results show enhanced ductility, energy dissipation capacity and damage tolerance behavior with the increase in steel fibers percentage in SCC.


2013 ◽  
Vol 753-755 ◽  
pp. 719-723
Author(s):  
Xi Kang Yan ◽  
Kang Ma ◽  
Cheng Dong ◽  
Lei Wang ◽  
Pei Chen

Based on experiment of a two-bay two-story reinforced concrete frame with construction joint under low-reversed cyclic loading, hysteretic performance, displacement ductility, bearing capacity degeneration, rigidity degeneration, energy dissipation and displacement restoring capacity are studied systematically. The studies show that the frame with construction joint has not better seismic performance than the monolithic cast frame.


PCI Journal ◽  
1998 ◽  
Vol 43 (6) ◽  
pp. 58-71 ◽  
Author(s):  
Rosa M. Vasconez ◽  
Antoine E. Naaman ◽  
James K. Wight

2012 ◽  
Vol 626 ◽  
pp. 85-89 ◽  
Author(s):  
Kay Dora Abdul Ghani ◽  
Nor Hayati Hamid

The experimental work on two full-scale precast concrete beam-column corner joints with corbels was carried out and their seismic performance was examined. The first specimen was constructed without steel fiber, while second specimen was constructed by mixed up steel fiber with concrete and placed it at the corbels area. The specimen were tested under reversible lateral cyclic loading up to ±1.5% drift. The experimental results showed that for the first specimen, the cracks start to occur at +0.5% drifts with spalling of concrete and major cracks were observed at corbel while for the second specimen, the initial cracks were observed at +0.75% with no damage at corbel. In this study, it can be concluded that precast beam-column joint without steel fiber has better ductility and stiffness than precast beam-column joint with steel fiber. However, precast beam-column joint with steel fiber has better energy dissipation and fewer cracks at corbel as compared to precast beam-column joint without steel fiber.


2016 ◽  
Vol 16 (01) ◽  
pp. 1640015 ◽  
Author(s):  
Yun Tian Wu ◽  
Yu Shan Fu ◽  
Chong-Ming Dai

A new type of partially steel tubed concrete (PSTC) column is proposed that is suitable to be used in new high rise reinforced concrete (RC) buildings. Three exterior joint specimens consisting of RC beams and PSTC columns and two exterior RC joint specimens were designed and tested under high axial load and cyclic loading to investigate the joint behavior in terms of failure pattern, hysteresis response, deformation, energy dissipation capacity and degradation of strength and stiffness. Test results indicate that the PSTC column can benefit the performance of the joint in terms of strength, ductility and energy dissipation capacity and can partly compensate for the unfavorable effect induced by slab. The strong column–weak beam mechanism can also be ensured in RC beam to PSTC column joint.


2014 ◽  
Vol 919-921 ◽  
pp. 1812-1816 ◽  
Author(s):  
Quan Dong Xiao ◽  
Zheng Xing Guo

To study the seismic behavior of Double-Wall Precast Concrete (DWPC) shear wall, three full scale specimens are tested and compared under low-cyclic reversed loading, including two DWPC shear walls and one normal Cast-In-Situ (CIS) shear wall. By observing their experimental phenomena and failure modes, contrasting their displacement ductility coefficients, hysteretic curves, skeleton curves and energy dissipation capacity, the seismic behavior were synthetically evaluated on aspects of strength, stiffness, ductility and energy dissipation. Compared with CIS specimen, DWPC specimens have higher initial stiffness, increased cracking loads by 43% to 47%, and the ultimate loads increased by 22% to 23%. The displacement ductility ratios also meet the ductility requirements with value of 5. The hysteretic curves of three specimens are plump, and the trend of skeleton curves is basically the same. The DWPC specimens demonstrated a good energy dissipation capacity. All the specimens had shown favorable seismic performance.


2012 ◽  
Vol 256-259 ◽  
pp. 2079-2084 ◽  
Author(s):  
Tie Cheng Wang ◽  
An Gao ◽  
Hai Long Zhao

The influence of the pile type and the stirrup on the seismic performance was evaluated based on the results of reversed cyclic loading tests on the four prestressed high strength concrete (PHC) piles. It is indicated that the AB-type pile has the better seismic performance than the A-type pile from the results. The bearing capacity does not increase obviously with decreasing of the stirrup spacing and increasing of the stirrup diameter. The degradation of stiffness does not decrease significantly with decreasing of the stirrup spacing and increasing of the stirrup diameter. The energy dissipation capacity is improved with increasing of the stirrup diameter and decreasing of the stirrup spacing.


Author(s):  
Xiang Hu ◽  
Weichen Xue ◽  
Yanbo Sun ◽  
Chenguang Li

A new type of precast steel reinforced concrete (PSRC) frame, which were composed of composite steel reinforced concrete (CSRC) beam, PSRC column and cast-in-situ (CIS) joint, were proposed in this paper. The assemble technique used in the ordinary steel structures were adopted in PSRC frames to improve the construction efficiency. The seismic performance of PSRC frame structures was investigated based on the test results of connections and frame. Firstly, full-scale internal connection specimens, including a CIS connection specimen RCJ-1 and a PSRC connection specimen PCJ-1, were tested under low reversed cyclic loading. Results revealed that both the specimens RCJ-1 and PCJ-1 exhibited similar performance in terms of loading capacity, stiffness degradation and energy dissipation. The ductility of specimen PCJ-1 was about 3.81, which was a little lower than the specimen RCJ-1. Then, a 1/3-scale PSRC frame structure specimen, namely PCF-1, was tested under low reversed cyclic loading. Results showed that the PSRC frame specimen PCF-1 was failed in mixed failure mechanism, which provide good energy dissipation capacity. The ductility coefficient of PCF-1 was about 3.45 indicating that the PCF-1 behaved in ductility manner. The results of this investigation could enrich the data available documenting the behavior of PSRC frame, and contribute to enlarge the application of PSRC frame structures in seismic zone.


Sign in / Sign up

Export Citation Format

Share Document