Upgrading of isolated bridges with space-bar energy-dissipation devices: Shaking table test

2021 ◽  
pp. 136943322110139
Author(s):  
Jelena Ristic ◽  
Zoran Brujic ◽  
Danilo Ristic ◽  
Radomir Folic ◽  
Milos Boskovic

The results of the experimental research program realized on a bridge model constructed by using the seismically isolated system upgraded with space-bar devices (USI-SB) are presented in the paper. The installed adaptable system for seismic protection of bridges utilizes double spherical rolling seismic bearings (DSRSB) as seismic isolators, while the qualitative improvement of seismic performances is achieved through the use of novel adjustable multi-directional space-bar energy dissipation (SB-ED) devices. The experimental program consisted of quasi-static testing of isolation and energy dissipation devices under the cyclic loading and extensive shaking-table testing of a large-scale bridge model with installed USI-SB system. For both types of devices, a very stable all-directional response during cycling tests, as well as the favorable hysteretic behavior of the energy dissipation devices along the entire range of applied large displacements were registered. In the dynamic testing, the system showed high seismic response modification performances needed for the efficient protection, exhibiting its large potential in the qualitative improvement of seismic performances of isolated bridges.

Author(s):  
S. Gao ◽  
Z. Ye ◽  
C. Wei ◽  
X. Liu ◽  
X. Tong

<p><strong>Abstract.</strong> The high-speed videogrammetric measurement system, which provides a convenient way to capture three-dimensional (3D) dynamic response of moving objects, has been widely used in various applications due to its remarkable advantages including non-contact, flexibility and high precision. This paper presents a distributed high-speed videogrammetric measurement system suitable for monitoring of large-scale structures. The overall framework consists of hardware and software two parts, namely observation network construction and data processing. The core component of the observation network is high-speed cameras to provide multiview image sequences. The data processing part automatically obtains the 3D structural deformations of the key points from the captured image sequences. A distributed parallel processing framework is adopted to speed up the image sequence processing. An empirical experiment was conducted to measure the dynamics of a double-tube five-layer building structure on the shaking table using the presented videogrammetric measurement system. Compared with the high-accuracy total station measurement, the presented system can achieve a sub-millimeter level of coordinates discrepancy. The 3D deformation results demonstrate the potential of the non-contact high-speed videogrammetric measurement system in dynamic monitoring of large-scale shake table tests.</p>


Author(s):  
Tadashi Mikoshiba ◽  
Chikahiro Minowa ◽  
Takanori Sato ◽  
Li Shao ◽  
Toshio Chiba

Under the effect of a large earthquake, the range of plastic comes into the column and the beam of the frame structure. By using energy dissipation devices, it is possible to reduce the response and the damage of the structure. A friction type damper which was a compact form and had high damping characteristics, was developed. It was made of steel plate, aluminum sliding plate, rubber washer and high tension bolt. To validate the performance of the new damper, the elemental tests and the shaking table test were conducted. In the shaking table test, frame structure composed of full scale member with friction damper was excited by actual seismic wave. As a result, it was found effective and had a high damping performance. This paper mainly reports the results of the shaking table test.


2019 ◽  
Vol 2019 ◽  
pp. 1-16 ◽  
Author(s):  
Yunxiu Dong ◽  
Zhongju Feng ◽  
Jingbin He ◽  
Huiyun Chen ◽  
Guan Jiang ◽  
...  

Puqian Bridge is located in a quake-prone area in an 8-degree seismic fortification intensity zone, and the design of the peak ground motion is the highest grade worldwide. Nevertheless, the seismic design of the pile foundation has not been evaluated with regard to earthquake damage and the seismic issues of the pile foundation are particularly noticeable. We conducted a large-scale shaking table test (STT) to determine the dynamic characteristic of the bridge pile foundation. An artificial mass model was used to determine the mechanism of the bridge pile-soil interaction, and the peak ground acceleration range of 0.15 g–0.60 g (g is gravity acceleration) was selected as the input seismic intensity. The results indicated that the peak acceleration decreased from the top to the bottom of the bridge pile and the acceleration amplification factor decreased with the increase in seismic intensity. When the seismic intensity is greater than 0.50 g, the acceleration amplification factor at the top of the pile stabilizes at 1.32. The bedrock surface had a relatively small influence on the amplification of the seismic wave, whereas the overburden had a marked influence on the amplification of the seismic wave and filtering effect. Damage to the pile foundation was observed at 0.50 g seismic intensity. When the seismic intensity was greater than 0.50 g, the fundamental frequency of the pile foundation decreased slowly and tended to stabilize at 0.87 Hz. The bending moment was larger at the junction of the pile and cap, the soft-hard soil interface, and the bedrock surface, where cracks easily occurred. These positions should be focused on during the design of pile foundations in meizoseismal areas.


2019 ◽  
Vol 23 (1) ◽  
pp. 37-50 ◽  
Author(s):  
Jihong Bi ◽  
Lanfang Luo ◽  
Nan Jiang

Dynamic equations are presented that have been deduced for a real-time dynamic substructuring shaking table test of an equipment-structure system, based on the branch mode substructure method. The equipment is adopted as the experimental substructure, which is loaded by the shaking table, while the structure is adopted as the numerical substructure. Real-time data communication occurs between the two substructures during the test. A real-time seismic energy calculation method was proposed for the calculation of energy responses, both in the experimental substructure and the numerical substructure. Taking a representative four-story steel frame/equipment model, real-time dynamic substructuring shaking table tests and overall model tests were executed. The proposed real-time dynamic substructuring shaking table testing method was verified by comparing the test results with shaking table test results for the overall model. The energy responses of each component in the equipment-structure system, using different connection types, also were studied. Changes in the connection types can lead to changes in the energy responses of the equipment-structure system, especially with respect to the equipment. The choice of the connection for the equipment-structure coupled system should take into account the operational performance objective of the equipment.


2015 ◽  
Vol 112 (2) ◽  
Author(s):  
T. Nagae ◽  
W. M. Ghannoum ◽  
J. Kwon ◽  
K. Tahara ◽  
K. Fukuyama ◽  
...  

2012 ◽  
Vol 166-169 ◽  
pp. 730-733 ◽  
Author(s):  
Fei Zhu ◽  
Feng Lai Wang ◽  
Xu Jie Sun ◽  
Y. Zhao

Unreinforced stone masonry pagodas have great cultural value and should be detailed investigation its mechanical properties. These buildings were not designed to resist earthquakes in ancient China, at least not in the way of current methods. The objectives of this research were to understand the dynamic behavior of unreinforced stone masonry pagoda and its seismic performance. To accomplish these, a 1/12 scale model of China Dinosaurs Pagoda was constructed and tested on shaking table. The octangle model height is 3.96m, with aspect ratio of height to width is 2.93, both parameters exceed the stipulated limit of Code for Seismic Design of Building. The model built with the stones and motars similar to the prototype materials and the arrangements. Its dynamic behavior and seismic performance were tested on the shaking table towards the free vibration and three earthquake waves. The experimental program adopted in the research is explained in this paper.


2012 ◽  
Vol 256-259 ◽  
pp. 1492-1495
Author(s):  
Xiao Yu Yan

To investigate the seismic response of long-span rigid frame bridges with high-pier, the shaking table test of a 1/10 scaled rigid frame bridge model is introduced in this paper. Details about test equipment, model design, test arrangement, input ground motion waves and test principle are provided. The response of bridge model under the seismic excitation included the uniform excitation and the multi-support excitation is observed. The influence of the soil-structure interaction on the bridge is considered through the real-time dynamic hybrid testing method. The impact effect for different ground motion input during the test is discussed. The influence of multi-support excitation, soil-structure interaction and impact effect on structural seismic responses are studied based on the test results. The isolation effectiveness and the damping effect are discussed as well.