Effect of the angle of the laid-up filaments on the surfaces on the coefficient of static friction between parts manufactured by extrusion-based 3D printing

Author(s):  
Leonardo Santana ◽  
Jorge Lino Alves ◽  
Aurélio da Costa Sabino Netto

Three-dimensional printers, particularly the extrusion-based ones, are driving a global academic, industrial, and social revolution. The accessibility of the technology has allowed a number of enthusiasts and scientists to dedicate efforts to improve the technical properties of the parts produced. However, there is little literature on the measurement of the coefficient of friction, especially the static one, between a pair of printed parts. In this sense, an investigation was carried out in two stages, in which at first the static coefficient of friction was measured, through a simple apparatus based on the concept of the inclined plane, varying the angle of the filaments laid up on the surfaces of the two parts in contact. The parameter was analyzed at three levels—0°, 45°, and 90°—in components manufactured in poly(lactic acid) and poly(ethylene glycol terephthalate). In the second part of the research, a case study was carried out to test and validate the effects of the best and worst friction conditions on the behavior of the insertion force of snap-fit connections. The results obtained show a significant influence of the filament angle in the interaction between two printed parts. Combinations of contact with different angles decrease the static coefficient of friction, while faces with equal angles tend to increase the magnitude of the response, especially if the arrangement of the filaments allows a fit of the surfaces opposite to sliding. The static coefficient of friction of poly(lactic acid) varied from 0.12 to 0.38, while the static coefficient of friction of poly(ethylene glycol terephthalate) varied from 0.13 to 0.21. The responses of the inclined plane test allowed to predict the behavior of the insertion force and plan the design of quick fittings.

2015 ◽  
Vol 133 (8) ◽  
pp. n/a-n/a ◽  
Author(s):  
Weraporn Pivsa-Art ◽  
Kazunori Fujii ◽  
Keiichiro Nomura ◽  
Yuji Aso ◽  
Hitomi Ohara ◽  
...  

Author(s):  
Mihir Sheth ◽  
R. Ananda Kumar ◽  
Vipul Dav� ◽  
Richard A. Gross ◽  
Stephen P. McCarthy

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Monika Dvořáková ◽  
Eva Rollerová ◽  
Soňa Scsuková ◽  
Alžbeta Bujňáková Mlynarčíková ◽  
Lucia Laubertová ◽  
...  

Our goal was to evaluate the potential health risk of the polymeric NP, poly(ethylene glycol)-block-poly(lactic acid) (PEG-b-PLA), from the view of redox imbalance of the organism in two different life stages. Female Wistar rats were neonatally administered intraperitoneally with PEG-b-PLA NPs [20 mg/kg of b.w. (PEG20) or 40 (PEG40) mg/kg of b.w.] from postnatal day 4 (PND4) to PND7. We measured antioxidant capacity (TEAC), level of protein carbonyls and lipoperoxides in plasma, activities of catalase, glutathione peroxidase (GPx), and superoxide dismutase (SOD) in hemolysates of infantile (sacrificed on PND17) and adult (sacrificed after PND176) rats. Compared to controls, neonatal PEG40 exposure induced a significant TEAC reduction in the infantile rats. Protein carbonyls and lipoperoxide levels were not affected after any dose of PEG-b-PLA NP administration. In adult rats, PEG20 administration caused a significant decrease of protein carbonyl levels compared to controls. In infantile rats, both doses of PEG-b-PLA NP administration increased catalase, Gpx, and SOD activities compared to controls. Surprisingly, in adult rats, the activities of Gpx and SOD decreased significantly after administration of both doses of PEG-b-PLA NPs. Obtained data indicate a possible age-related association between the oxidative status and neonatal PEG-b-PLA NP administration in female rats.


Sign in / Sign up

Export Citation Format

Share Document