Reliability and Validity of the Posture and Fine Motor Assessment of Infants

1989 ◽  
Vol 9 (5) ◽  
pp. 259-272 ◽  
Author(s):  
Jane Case-Smith

The Posture and Fine Motor Assessment of Infants (PFMAI) (Case-Smith, 1987) is a newly developed instrument for assessing the quality of motor function in infants. The test measures components of posture and fine motor control as they first develop. The purpose of this study was to support the test's reliability and validity. Interrater reliability, analyzed with intraclass correlation coefficients (ICCs), was high (.989 for total scores). Test-retest reliability, measured by ICCs, was .853 and .913 for the two test sections. The PFMAI demonstrated concurrent validity with the Peabody Developmental Motor Scales, Revised (Folio & Fewell, 1983) (correlations were .673 and .829 for the individual sections). Scores on the PFMAI were highly correlated with the infant's ages (.892 to .941); this finding provided one indication of construct validity.

2015 ◽  
Vol 31 (3) ◽  
pp. 159-163 ◽  
Author(s):  
Nathan W. Saunders ◽  
Panagiotis Koutakis ◽  
Anne D. Kloos ◽  
Deborah A. Kegelmeyer ◽  
Jessica D. Dicke ◽  
...  

Clinicians are in need of valid and objective measures of postural sway. Accelerometers have been shown to be suitable alternatives to expensive and stationary force plates. We evaluated the test-retest reliability and balance task discrimination capability of a new wireless triaxial accelerometer (YEI 3-Space Sensor). Four testing conditions (eyes open or closed, while on a firm or compliant surface) were used to progressively challenge the static balance of 20 healthy male (n = 8) and female (n = 12) older adults (mean age 81 ± 4.3 y). Subjects completed 2 blocks of three 30-second trials per condition. The accelerometer was positioned on the lower back to acquire mediolateral (M-L) and anterior-posterior (A-P) accelerations. Intraclass correlation coefficients were all good to excellent, with values ranging from .736 to .972 for trial-to-trial and from .760 to .954 for block-to-block. A significant stepwise increase in center of mass acceleration root mean square values was found across the 4 balance conditions (F[1.49, 28.26] = 39.54, P < .001). The new accelerometer exhibited good to excellent trial-to-trial and block-to-block reliability and was sensitive to differences in visual and surface conditions and acceleration axes.


Author(s):  
Kanako Kondo ◽  
Masanobu Mizuta ◽  
Yoshitaka Kawai ◽  
Tohru Sogami ◽  
Shintaro Fujimura ◽  
...  

Purpose: Auditory-perceptual evaluation is essential for the assessment of voice quality. The Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V) provides a standardized protocol and assessment form for clinicians to analyze the voice quality and has been adapted into several different languages. The aims of this study were to develop the Japanese version of the CAPE-V and to investigate its reliability and validity. Method: The Japanese CAPE-V consisted of the same three speech contexts (vowels, sentences, and conversation) as developed in the original English version. The sentences were designed according to the concepts of the original version and reviewed by Japanese phoneticians. To validate the usefulness of the Japanese CAPE-V, voices of 173 Japanese-speaking subjects (76 subjects with dysphonia and 97 without voice complaints) were evaluated by five experienced judges, according to the Japanese CAPE-V as well as the GRBAS (Grade, Roughness, Breathiness, Asthenia, Strain) scale. Results: The Japanese CAPE-V provided a high interrater reliability (intraclass correlation coefficients [ICCs] > .85 for all the parameters) as well as a high intrarater reliability (ICCs > .85 for all the parameters). In addition, overall severity, roughness, and breathiness in the Japanese CAPE-V were highly correlated with the corresponding dimensions in the GRBAS scale, having Spearman correlation coefficients greater than .8. Conclusion: This study demonstrated the reliability and validity of the newly developed Japanese CAPE-V as an auditory-perceptual evaluation instrument.


2011 ◽  
Vol 23 (7) ◽  
pp. 1124-1132 ◽  
Author(s):  
Luc P. De Vreese ◽  
Ulrico Mantesso ◽  
Elisa De Bastiani ◽  
Annachiara Marangoni ◽  
Tiziano Gomiero

ABSTRACTBackground: The aim of this study was to verify the reliability and validity of the Italian version of the Assessment for Adults with Developmental Disabilities (AADS-I), the only available measure specifically designed to assess the frequency, management difficulties and impact on the quality of life (QoL) of positive and negative non-cognitive symptoms in persons with intellectual disabilities (ID) and dementia.Methods: AADS-I was administered to professional carers of 63 aging ID individuals. We computed the internal consistency separately of the frequency, management difficulty and effect on the QoL subscales of Behavioral Excesses and Behavioral Deficits and their inter-rater and test-retest reliabilities.Results: Homogeneity of AADS-I was found to range from good to excellent: Cronbach's α coefficients were 0.77, 0.83 and 0.82, respectively for frequency, management difficulty and effect on the QoL of Behavioral Excesses, and 0.82, 0.76 and 0.79 of Behavioral Deficits. Intraclass correlation coefficients (ICC) between two independent carers were 0.67, 0.79 and 0.73 and 0.67, 0.67 and 0.67 for frequency, management difficulty and effect on the QoL of Behavioral Excesses and Deficits, respectively. Corresponding ICC for test-retest reliability were 0.80, 0.75, 0.78 and 0.70, 0.81, 0.81. Age, gender and typology of ID did not correlate with the AADS-I subscale scores, whereas the severity of ID related only with the frequency subscale of Behavioral Deficits. This subscale also correlated with the Dementia Questionnaire for Persons with Intellectual Disabilities. Behavioral deficits are more frequent in subjects with dementia.Conclusions: These results confirm the reliability and validity of the Italian version of AADS.


2006 ◽  
Vol 86 (1) ◽  
pp. 66-76 ◽  
Author(s):  
Geert Verheyden ◽  
Godelieve Nuyens ◽  
Alice Nieuwboer ◽  
Pol Van Asch ◽  
Piet Ketelaer ◽  
...  

Abstract Background and Purpose. Standardized scales are a prerequisite for rehabilitation and research. This study was designed to determine the reliability and validity of scores on items of the trunk assessment of the Melsbroek Disability Scoring Test (MDST) and Trunk Impairment Scale (TIS) in people with multiple sclerosis (MS). Subjects. Thirty people with MS participated in the study. Methods. Interrater and test-retest reliability and construct validity were assessed. Results. Kappa and weighted kappa values for the items of the trunk assessment of the MDST ranged from .74 to .95, and the kappa and weighted kappa values for the TIS items ranged from .46 to 1.00. Intraclass correlation coefficients for interrater and test-retest agreement were .93 and .92, respectively, for the trunk assessment of the MDST and .97 and .95, respectively, for the TIS. Bland-Altman analysis showed consistency of scores without observer bias. Construct validity was established. Discussion and Conclusion. The MDST and TIS provide reliable assessments of the trunk and are valid scales for measuring trunk performance in people with MS. [Verheyden G, Nuyens G, Nieuwboer A, et al. Reliability and validity of trunk assessment for people with multiple sclerosis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


2020 ◽  
Author(s):  
Jiangang Sun ◽  
Yang Liu

BACKGROUND An increasing number of wrist-worn wearables are being examined in the context of health care. However, studies of their use during physical education (PE) lessons remain scarce. OBJECTIVE We aim to examine the reliability and validity of the Fizzo Smart Bracelet (Fizzo) in measuring heart rate (HR) in the laboratory and during PE lessons. METHODS In Study 1, 11 healthy subjects (median age 22.0 years, IQR 3.75 years) twice completed a test that involved running on a treadmill at 6 km/h for 12 minutes and 12 km/h for 5 minutes. During the test, participants wore two Fizzo devices, one each on their left and right wrists, to measure their HR. At the same time, the Polar Team2 Pro (Polar), which is worn on the chest, was used as the standard. In Study 2, we went to 10 schools and measured the HR of 24 students (median age 14.0 years, IQR 2.0 years) during PE lessons. During the PE lessons, each student wore a Polar device on their chest and a Fizzo on their right wrist to measure HR data. At the end of the PE lessons, the students and their teachers completed a questionnaire where they assessed the feasibility of Fizzo. The measurements taken by the left wrist Fizzo and the right wrist Fizzo were compared to estimate reliability, while the Fizzo measurements were compared to the Polar measurements to estimate validity. To measure reliability, intraclass correlation coefficients (ICC), mean difference (MD), standard error of measurement (SEM), and mean absolute percentage errors (MAPE) were used. To measure validity, ICC, limits of agreement (LOA), and MAPE were calculated and Bland-Altman plots were constructed. Percentage values were used to estimate the feasibility of Fizzo. RESULTS The Fizzo showed excellent reliability and validity in the laboratory and moderate validity in a PE lesson setting. In Study 1, reliability was excellent (ICC&gt;0.97; MD&lt;0.7; SEM&lt;0.56; MAPE&lt;1.45%). The validity as determined by comparing the left wrist Fizzo and right wrist Fizzo was excellent (ICC&gt;0.98; MAPE&lt;1.85%). Bland-Altman plots showed a strong correlation between left wrist Fizzo measurements (bias=0.48, LOA=–3.94 to 4.89 beats per minute) and right wrist Fizzo measurements (bias=0.56, LOA=–4.60 to 5.72 beats per minute). In Study 2, the validity of the Fizzo was lower compared to that found in Study 1 but still moderate (ICC&gt;0.70; MAPE&lt;9.0%). The Fizzo showed broader LOA in the Bland-Altman plots during the PE lessons (bias=–2.60, LOA=–38.89 to 33.69 beats per minute). Most participants considered the Fizzo very comfortable and easy to put on. All teachers thought the Fizzo was helpful. CONCLUSIONS When participants ran on a treadmill in the laboratory, both left and right wrist Fizzo measurements were accurate. The validity of the Fizzo was lower in PE lessons but still reached a moderate level. The Fizzo is feasible for use during PE lessons.


2006 ◽  
Vol 86 (8) ◽  
pp. 1107-1117 ◽  
Author(s):  
Olaf Verschuren ◽  
Tim Takken ◽  
Marjolijn Ketelaar ◽  
Jan Willem Gorter ◽  
Paul JM Helders

Abstract Background and Purpose. The purpose of this study was to examine the reliability and validity of data obtained with 2 newly developed shuttle run tests (SRT-I and SRT-II) to measure aerobic power in children with cerebral palsy (CP) who were classified at level I or II on the Gross Motor Function Classification System (GMFCS). The SRT-I was developed for children at GMFCS level I, and the SRT-II was developed for children at GMFCS level II. Subjects. Twenty-five children and adolescents with CP (10 female, 15 male; mean age=11.9 years, SD=2.9), classified at GMFCS level I (n=14) or level II (n=11), participated in the study. Methods. To assess test-retest reliability of data for the 10-m shuttle run tests, the subjects performed the same test within 2 weeks. To examine validity, the shuttle run tests were compared with a GMFCS level–based treadmill test designed to measure peak oxygen uptake. Results. Statistical analyses revealed test-retest reliability for exercise time (number of levels completed) (intraclass correlation coefficients of .97 for the SRT-I and .99 for the SRT-II) and reliability for peak heart rate attained during the final level (intraclass correlation coefficients of .87 for the SRT-I and .94 for the SRT-II). High correlations were found for the relationship between data for both shuttle run tests and data for the treadmill test (r=.96 for both). Discussion and Conclusion. The results suggest that both 10-m shuttle run tests yield reliable and valid data. Moreover, the shuttle run tests have advantages over a treadmill test for children with CP who are able to walk and run (GMFCS level I or II). [Verschuren O, Takken T, Ketelaar M, et al. Reliability and validity of data for 2 newly developed shuttle run tests in children with cerebral palsy. Phys Ther. 2006;86:1107–1117.]


Sensors ◽  
2019 ◽  
Vol 19 (2) ◽  
pp. 265 ◽  
Author(s):  
Kristen Renner ◽  
DS Williams ◽  
Robin Queen

The assessment of loading during walking and running has historically been limited to data collection in laboratory settings or with devices that require a computer connection. This study aims to determine if the loadsol®—a single sensor wireless insole—is a valid and reliable method of assessing force. Thirty (17 male and 13 female) recreationally active individuals were recruited for a two visit study where they walked (1.3 m/s) and ran (3.0 and 3.5 m/s) at a 0%, 10% incline, and 10% decline, with the visits approximately one week apart. Ground reaction force data was collected on an instrumented treadmill (1440 Hz) and with the loadsol® (100 Hz). Ten individuals completed the day 1 protocol with a newer 200 Hz loadsol®. Intraclass correlation coefficients (ICC3,k) were used to assess validity and reliability and Bland–Altman plots were generated to better understand loadsol® validity. Across conditions, the peak force ICCs ranged from 0.78 to 0.97, which increased to 0.84–0.99 with the 200 Hz insoles. Similarly, the loading rate ICCs improved from 0.61 to 0.97 to 0.80–0.96 and impulse improved from 0.61 to 0.97 to 0.90–0.97. The 200 Hz insoles may be needed for loading rate and impulse in running. For both walking and running, the loadsol® has excellent between-day reliability (>0.76).


Sign in / Sign up

Export Citation Format

Share Document