Nano-mechanical Properties of Fluoride-treated Enamel Surfaces

2008 ◽  
Vol 87 (4) ◽  
pp. 381-385 ◽  
Author(s):  
Y.-R. Jeng ◽  
T.-T. Lin ◽  
T.-Y. Wong ◽  
H.-J. Chang ◽  
D.-B. Shieh

Calcium-fluoride-like deposits play a key role in caries prevention by topical fluoride. Previous microhardness analyses have introduced errors due to a substrate effect, and thereby could not substantiate the early loss of these deposits. To address this question, we applied Atomic Force Microscopy (AFM) and a nano-indentation technique in this study to characterize the nano-mechanical properties and topographic structure of enamel surfaces following topical fluoride treatment. The deposits were found to have a low nano-hardness and a high nano-wear depth, which explains the early loss of calcium-fluoride-like deposits. However, a 22% increase in the fluoride concentration could still be detected on the treated enamel surface following the removal of the surface deposits, justifying the long-term effectiveness of topical fluoride treatment.

2019 ◽  
Vol 9 (1) ◽  
Author(s):  
A. Amir Hassan ◽  
Miguel V. Vitorino ◽  
Tiago Robalo ◽  
Mário S. Rodrigues ◽  
Isabel Sá-Correia

Abstract The influence that Burkholderia cenocepacia adaptive evolution during long-term infection in cystic fibrosis (CF) patients has on cell wall morphology and mechanical properties is poorly understood despite their crucial role in cell physiology, persistent infection and pathogenesis. Cell wall morphology and physical properties of three B. cenocepacia isolates collected from a CF patient over a period of 3.5 years were compared using atomic force microscopy (AFM). These serial clonal variants include the first isolate retrieved from the patient and two late isolates obtained after three years of infection and before the patient’s death with cepacia syndrome. A consistent and progressive decrease of cell height and a cell shape evolution during infection, from the typical rods to morphology closer to cocci, were observed. The images of cells grown in biofilms showed an identical cell size reduction pattern. Additionally, the apparent elasticity modulus significantly decreases from the early isolate to the last clonal variant retrieved from the patient but the intermediary highly antibiotic resistant clonal isolate showed the highest elasticity values. Concerning the adhesion of bacteria surface to the AFM tip, the first isolate was found to adhere better than the late isolates whose lipopolysaccharide (LPS) structure loss the O-antigen (OAg) during CF infection. The OAg is known to influence Gram-negative bacteria adhesion and be an important factor in B. cenocepacia adaptation to chronic infection. Results reinforce the concept of the occurrence of phenotypic heterogeneity and adaptive evolution, also at the level of cell size, form, envelope topography and physical properties during long-term infection.


2000 ◽  
Vol 39 (Part 1, No. 6B) ◽  
pp. 3711-3716 ◽  
Author(s):  
Hatsuki Shiga ◽  
Yukako Yamane ◽  
Etsuro Ito ◽  
Kazuhiro Abe ◽  
Kazushige Kawabata ◽  
...  

Coatings ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 652
Author(s):  
Divine Sebastian ◽  
Chun-Wei Yao ◽  
Lutfun Nipa ◽  
Ian Lian ◽  
Gary Twu

In this work, a mechanically durable anticorrosion superhydrophobic coating is developed using a nanocomposite coating solution composed of silica nanoparticles and epoxy resin. The nanocomposite coating developed was tested for its superhydrophobic behavior using goniometry; surface morphology using scanning electron microscopy and atomic force microscopy; elemental composition using energy dispersive X-ray spectroscopy; corrosion resistance using atomic force microscopy; and potentiodynamic polarization measurements. The nanocomposite coating possesses hierarchical micro/nanostructures, according to the scanning electron microscopy images, and the presence of such structures was further confirmed by the atomic force microscopy images. The developed nanocomposite coating was found to be highly superhydrophobic as well as corrosion resistant, according to the results from static contact angle measurement and potentiodynamic polarization measurement, respectively. The abrasion resistance and mechanical durability of the nanocomposite coating were studied by abrasion tests, and the mechanical properties such as reduced modulus and Berkovich hardness were evaluated with the aid of nanoindentation tests.


Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1661
Author(s):  
Katarzyna Adamiak ◽  
Katarzyna Lewandowska ◽  
Alina Sionkowska

Collagen films are widely used as adhesives in medicine and cosmetology. However, its properties require modification. In this work, the influence of salicin on the properties of collagen solution and films was studied. Collagen was extracted from silver carp skin. The rheological properties of collagen solutions with and without salicin were characterized by steady shear tests. Thin collagen films were prepared by solvent evaporation. The structure of films was researched using infrared spectroscopy. The surface properties of films were investigated using Atomic Force Microscopy (AFM). Mechanical properties were measured as well. It was found that the addition of salicin modified the roughness of collagen films and their mechanical and rheological properties. The above-mentioned parameters are very important in potential applications of collagen films containing salicin.


2018 ◽  
Vol 114 (3) ◽  
pp. 513a
Author(s):  
Yuri M. Efremov ◽  
Mirian Velay-Lizancos ◽  
Daniel M. Suter ◽  
Pablo D. Zavattieri ◽  
Arvind Raman

PLoS ONE ◽  
2012 ◽  
Vol 7 (1) ◽  
pp. e30204 ◽  
Author(s):  
David Martinez-Martin ◽  
Carolina Carrasco ◽  
Mercedes Hernando-Perez ◽  
Pedro J. de Pablo ◽  
Julio Gomez-Herrero ◽  
...  

2018 ◽  
Vol 2 (2) ◽  
pp. 14-17
Author(s):  
Zhuola Zhuola ◽  
Steve Barrett ◽  
Yalda Ashraf Kharaz ◽  
Riaz Akhtar

The mechanical properties of ocular tissues, such as the sclera, have a major impact on healthy eye function, and are governed by the properties and composition of the microstructural components. For example, biomechanical degradation associated with myopia occurs alongside a reduction of proteoglycans (PGs). In this study, the role of PG degradation in the nanomechanical properties of the porcine sclera is explored. In-vitro enzymatic degradation of PGs was conducted with α-amylase and chondroitinase ABC enzymes. Collagen fibril morphology and nanomechanical stiffness were measured with atomic force microscopy (AFM). The elastic modulus of the tissue was reduced in all enzyme-treated samples relative to controls. In addition, collagen fibril organization was disrupted by PG depletion. Our data demonstrate that PGs play an important role in determining not only the mechanical properties at these length scales, but also collagen fibril arrangement.


Author(s):  
Hosam Gharib Abdelhady

Objectives: This research aims at investigating the effect of nano-encapsulating the MagnevistTM, a magnetic resonance imaging agent, within generation four, 1, 4- diaminobutane core polyamidoamine dendrimers on their molecular morphology and their nano-mechanical properties in liquid.Methods: Atomic force microscopy was applied in its imaging and force measuring modes to investigate, on the molecular scale, the morphological and nano-mechanical changes in generation four, 1, 4-diaminobutane core polyamidoamine dendrimers due to the nano-encapsulation of Magnevist in liquid.Results: The weight gain of dendrimers indicates the loading of ~ 30 Magnevist molecules. This has increased the rigidity of the dendrimer molecules, compared to unloaded dendrimers. Atomic force microscopy showed individual well-defined nano-spherical particles with nanoscopic dimensions of (40±13 nm in diameter and 4.38±0.54 nm in height). In contrast, imaging of non encapsulated dendrimers revealed loose aggregates of 15±3.5 nm in diameter and 0.9±0.2 nm in height.Conclusions: The atomic force microscopy, in liquid, was successfully applied to differentiate between Magnevist nano-encapsulated and non-encapsulated dendrimers, in their morphology and in their nano-mechanical properties. The results confirm the nano-encapsulation of Magnevist within generation four, 1,4-diaminobutane core polyamidoamine dendrimers. This loading increased the rigidity of the nanoencapsulated dendrimer, packed ~ 9 Magnevist-G 4 molecules together and may probably enhance the magnetic resonance images and increase their duration of time in the bloodstream when compared with Magnevist alone. Thus elongating the imaging sessions without the need for additional contrast agent doses.


Sign in / Sign up

Export Citation Format

Share Document