scholarly journals Diagnosis accuracy of serum glypican-3 level in patients with hepatocellular carcinoma: a systematic review with meta-analysis

2018 ◽  
Vol 33 (4) ◽  
pp. 353-363 ◽  
Author(s):  
Jian Li ◽  
Tiezheng Wang ◽  
Boxun Jin ◽  
Wenlei Li ◽  
Zhenshun Wang ◽  
...  

Background: Previous studies have evaluated the diagnostic value of serum glypican-3 in patients with hepatocellular carcinoma. However, the results remain inconsistent and even controversial. Thus, the aim of the present meta-analysis was to clarify the diagnostic accuracy of serum glypican-3 for hepatocellular carcinoma. Methods: A meta-analysis including 22 studies was performed with 2325 cases and 2280 controls. Relevant studies were searched in the EMBASE, PubMed, and Web of Science databases, covering relevant papers published until November 1, 2017. The quality of the studies was assessed by revised QUADAS tools. Sensitivity, specificity, and other measures were pooled and determined to evaluate the accuracy of serum glypican-3 in the diagnosis of hepatocellular carcinoma by random-effects models. Summary receiver operating characteristic curve (sROC) analysis was performed to summarize the overall test performance. Results: The results showed that the pooled overall diagnostic sensitivity, specificity, and 95% confidence interval (CI) for serum glypican-3 in the diagnosis of hepatocellular carcinoma were 68% (56-79%) and 92% (82-96.0%), respectively. Besides, the summary diagnostic odds ratio and 95% CI for glypican-3 were 23.53 (8.57-64.63). In addition, the area under sROC and 95% CI was 0.87 (0.84-0.90). The major design deficiencies of included studies were differential verification bias, and a lack of clear exclusion and inclusion criteria. Conclusions: The results of this meta-analysis suggested that serum glypican-3 was acceptable as a moderate diagnostic marker in the diagnosis of hepatocellular carcinoma compared with healthy individuals, which could elevate the sensitivity and specificity of diagnosis. Furthermore, more well-designed studies with large sample sizes are needed to show the effectiveness of glypican-3 in the differential diagnosis of hepatocellular carcinoma.

2017 ◽  
Vol 2017 ◽  
pp. 1-10 ◽  
Author(s):  
Jin Yan ◽  
Qiang She ◽  
Xiaoran Shen ◽  
Yifeng Zhang ◽  
Bingtuan Liu ◽  
...  

The association between circulating microRNA-375 (miR-375) expression and cancers has been studied; however, the results are inconsistent. We searched PubMed, Embase, and Web of Science for studies concerning the diagnostic value of miR-375 for cancer. The bivariate meta-analysis model was employed to summarize sensitivity, specificity, and diagnostic odds ratio (DOR) for miR-375 in the diagnosis of cancer. Summary receiver operating characteristic (SROC) curve analysis and the area under the curve (AUC) were also used to check the overall test performance. A total of 645 cancer patients and 421 cancer-free individuals from 12 studies were contained in this meta-analysis. The summary estimates revealed that the pooled sensitivity was 78% (95% confidence interval (CI): 64%–87%), the specificity was 74% (95% CI: 62%–84%), the DOR was 10.04 (95% CI: 6.01–16.77), and the AUC was 0.82 (95% CI: 0.79–0.85). In addition, we found that the diagnostic effect of miR-375 varies according to the race and cancer type. Our data suggest that miR-375 profiling has a potential to be used as a screening test for cancers but the specific race and cancer should be considered. More studies on the diagnostic value of miR-375 for cancer are needed in the future.


2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Xueying Wang ◽  
Yangyu Zhang ◽  
Na Yang ◽  
Hua He ◽  
Xuerong Tao ◽  
...  

The role of α-fetoprotein (AFP) in the surveillance and diagnosis of hepatocellular carcinoma (HCC) has been questioned in recent years due to its low sensitivity and specificity. In addition to AFP, several new serum biomarkers, such as lens culinaris agglutinin-reactive fraction of AFP (AFP-L3) and des-gamma-carboxy prothrombin (DCP), have also been identified as useful HCC serological markers. However, the exact diagnostic value of the combinations of these biomarkers for detecting HCC in patients with liver disease remains unclear. Thus, we performed the current meta-analysis to assess performance of AFP+AFP-L3%+DCP for diagnosing HCC. Studies were systematically searched in PubMed, Embase, the Cochrane Library, CNKI, and WanFang Data databases. After full-text evaluation, 13 studies from 11 articles focusing on the combination of the three serum biomarkers for HCC detection were enrolled. Random-effects models were used due to the presence of heterogeneity. The pooled sensitivity and specificity for AFP+AFP-L3%+DCP were 88% and 79%, respectively. The area under the summary receiver operating characteristic (sROC) curve was 0.91, and the diagnostic odds ratio (DOR) was 28.33 (95% CI 16.78-47.83). Subgroup analysis showed that the pooled sensitivity and specificity of AFP+AFP-L3%+DCP in the diagnosis of HCC versus cirrhosis patients were 0.81 and 0.82, respectively. In conclusion, the combination of AFP, AFP-L3%, and DCP may prove to be useful in the diagnosis and screening of HCC.


2018 ◽  
Author(s):  
Yan Miao ◽  
Ying Zhang ◽  
Lina Wang ◽  
Lihong Yin

ABSTRACTObjectivesEmerging evidence has shown that the expression level of microRNA-421 (miR-421) was significantly different between gastric cancer (GC) patients and healthy individuals. However, the diagnostic accuracy of miR-421 in the reports remains inconsistent. This meta-analysis aims to assess the diagnostic value of miR-421 in GC detection.MethodsAll related articles on miR-421 in GC diagnosis were retrieved until September 2018. The QUADAS-2 checklist was used to assess the methodological quality of each study. The diagnostic performance of miR-421 for GC were assessed by using Meta-DiSc 1.4 and STATA 14.0 statistical software.ResultsA total of 172 GC patients and 154 healthy controls from three articles (four studies) were enrolled in this meta-analysis. The results of pooled sensitivity, specificity, diagnostic odds ratio (DOR) with 95% confidence interval (CI) were 0.90 (95% CI: 0.85 to 0.93), 0.83 (95% CI: 0.77 to 0.87), and 37.18 (95% CI: 8.61 to 160.49), respectively. The area under the summary receiver operating characteristic curve (SROC) was 0.8977.ConclusionsThis study indicates that miR-421 could serve as a promising biomarker for GC detecting. Further studies are needed to verify the generalizability of these findings.


2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Lei Xi ◽  
Chunqing Yang

AbstractObjectivesThe main aim of the present study was to assess the diagnostic value of alpha-l-fucosidase (AFU) for hepatocellular carcinoma (HCC).MethodsStudies that explored the diagnostic value of AFU in HCC were searched in EMBASE, SCI, and PUBMED. The sensitivity, specificity, and DOR about the accuracy of serum AFU in the diagnosis of HCC were pooled. The methodological quality of each article was evaluated with QUADAS-2 (quality assessment for studies of diagnostic accuracy 2). Receiver operating characteristic curves (ROC) analysis was performed. Statistical analysis was conducted by using Review Manager 5 and Open Meta-analyst.ResultsEighteen studies were selected in this study. The pooled estimates for AFU vs. α-fetoprotein (AFP) in the diagnosis of HCC in 18 studies were as follows: sensitivity of 0.7352 (0.6827, 0.7818) vs. 0.7501 (0.6725, 0.8144), and specificity of 0.7681 (0.6946, 0.8283) vs. 0.8208 (0.7586, 0.8697), diagnostic odds ratio (DOR) of 7.974(5.302, 11.993) vs. 13.401 (8.359, 21.483), area under the curve (AUC) of 0.7968 vs. 0.8451, respectively.ConclusionsAFU is comparable to AFP for the diagnosis of HCC.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Weixing Liu ◽  
Gui Chen ◽  
Xin Gong ◽  
Yingqi Wang ◽  
Yaoming Zheng ◽  
...  

Abstract Background Numerous individual studies have investigated the diagnostic value of EBV-DNA, EA-IgA, VCA-IgA, EBNA1-IgA and Rta-IgG detection for nasopharyngeal carcinoma (NPC), but the conclusions remain controversial. This meta-analysis aimed to determine the value of EBV-DNA, EA-IgA, VCA-IgA, EBNA1-IgA and Rta-IgG detection in the diagnosis of NPC. Methods PROSPERO registration number: CRD42019145532. PubMed, EMBASE, Cochrane Library, and Chinese data libraries (Wanfang, CNKI, and CBM) were searched up to January 2019. The pooled sensitivity, specificity, and positive likelihood, negative likelihood, and diagnostic odds ratios were conducted in this meta-analysis. Summary receiver operating characteristic curves evaluated the test-performance global summary. Publication bias was examined by Deek’s funnel plot asymmetry test. Results Forty-seven studies with 8382 NPC patients (NPC group) and 15,089 individuals without NPC (Control group) were included in this meta-analysis. The sensitivity, specificity, positive likelihood (+ LR), negative likelihood (-LR), DOR and AUC of EBV-DNA in diagnosis of NPC were: 0.76 (95% CI 0.73–0.77), 0.96 (95% CI 0.95–0.97), 14.66 (95% CI 9.97–21.55), 0.19 (95% CI 0.13–0.28), 84 (95% CI 50.45–139.88), 0.96 (SE: 0.001), and 0.55 (95% CI 0.54–0.57), 0.96 (95% CI 0.96–0.97), 12.91 (95% CI 9.55–17.45), 0.35 (95% CI 0.29–0.43), 39.57 (95% CI 26.44–59.23), 0.94 (SE: 0.002) for the EA-IgA, and 0.85 (95% CI 0.84–0.85), 0.89 (95% CI 0.88–0.89), 6.73 (95% CI5.38–8.43), 0.17 (95% CI 0.12–0.23), 43.03 (95% CI 31.51–58.76), 0.93 (SE: 0.007) for the VCA-IgA, and 0.86 (95% CI 0.85–0.88), 0.87 (95% CI 0.88–0.90), 7.55 (95% CI 5.79–9.87), 0.16 (95% CI 0.13–0.19), 50.95 (95% CI 34.35–75.57), 0.94 (SE: 0.008) for the EBNA1-IgA, and 0.70 (95% CI 0.69–0.71), 0.94 (95% CI 0.94–0.95), 9.84 (95% CI 8.40–11.54), 0.25 (95% CI 0.21–0.31), 40.59 (95% CI 32.09–51.35), 0.95 (SE: 0.005) for the Rta-IgG. The EBV-DNA had larger AUC compared with other EBV-based antibodies (P < 0.05), while the difference between EA-IgA, VCA-IgA, EBNA1-IgA and Rta-IgG was not statistically significant (P > 0.05). Conclusions EBV-DNA, VCA-IgA, EBNA1-IgA and Rta-IgG detection have high accuracy in early diagnosis NPC. In addition, EBV-DNA detection has the higher diagnosis accuracy in NPC. On the other hand, EA-IgA is suitable for the diagnosis but not NPC screening.


2019 ◽  
Vol 25 (10) ◽  
pp. 1056-1066 ◽  
Author(s):  
Yang Zhao ◽  
Yinlong Zhao ◽  
Chunpeng Wang ◽  
Zhenzhen Liang ◽  
Xin Liu

Objective: A previous meta-analysis carried out on the predictive ability of anti-Müllerian hormone (AMH) for polycystic ovary syndrome (PCOS) showed that independent AMH may be a useful initial diagnostic test for PCOS. The aims of this study were to update the meta-analysis and to evaluate the diagnostic efficacy of AMH when it replaces polycystic ovary morphology (PCOM) in the Rotterdam criteria. Methods: Two independent reviewers searched PubMed, Cochrane Library, and the Web of Science databases systematically to identify relevant articles by using the key words “anti-Müllerian hormone” and “polycystic ovary syndrome.” The deadline for manuscript inclusion was July 31, 2018. A random effects model was used and subgroup analysis and meta regression were performed to identify possible sources of heterogeneity. The methodologic quality of each study was assessed by QUADAS-2 and funnel plot asymmetry test. Results: According to the inclusion criteria, 29 studies were included in this meta-analysis. The pooled sensitivity, specificity, and diagnostic odds ratio (DOR) for AMH alone detecting PCOS were 0.76 (95% confidence interval [CI] 0.71 to 0.81), 0.86 (95% CI 0.82 to 0.90) and 20 (95% CI 12 to 33), respectively. When AMH replaces polycystic ovary morphology (PCOM) for the diagnosis of PCOS, the pooled sensitivity, specificity, and DOR rose to 0.93 (95% CI 0.89 to 0.96), 0.99 (95% CI 0.95 to 1.00), and 1,634 (95% CI 217 to 12,324), respectively. The area under the summary receiver-operating characteristic curve for AMH alone and for AMH replacing PCOM detecting PCOS were 0.88 (95% CI 0.85 to 0.91) and 0.97 (95% CI 0.95 to 0.98), respectively, which was found to be significantly different ( Z = 4.89, P<.01). Conclusion: When AMH replaces PCOM in the Rotterdam criteria, the diagnostic efficacy for polycystic ovary syndrome is better. Abbreviations: AMH = anti-Müllerian hormone; AUC = area under the summary receiver operating characteristic curve; BMI = body mass index; CI = confidence interval; DOR = diagnostic odds ratio; HA = hyperandrogenism; IBC = Immunotech-Beckman Coulter; NLR = negative likelihood ratio; OA = oligo-anovulation; PCOM = polycystic ovary morphology; PCOS = polycystic ovary syndrome; PLR = positive likelihood ratio; QUADAS = the Quality Assessment of Diagnostic Accuracy Studies; SENS = sensitivity; SPEC = specificity


2014 ◽  
Vol 29 (4) ◽  
pp. 403-410 ◽  
Author(s):  
Jie Zhang ◽  
Ying Zhao ◽  
Qin Yang

Objective This meta-analysis evaluated the diagnostic accuracy of positive serum Dickkopf-1 (DKK1) for diagnosing hepatocellular carcinoma (HCC). Material and methods Articles listed on Embase, PubMed, Wanfang, Weipu Periodical Database or the Chinese National Knowledge Infrastructure (CNKI) and published up to July 10, 2013, were searched in either English or Chinese. The pooled sensitivity (SEN), specificity (SPE), positive and negative likelihood ratios (PLR and NLR), diagnostic odds ratio (DOR) and summary receiver operating characteristic (sROC) curve were calculated to summarize the overall test performance. Results Four articles (6 studies) provided DKK1 diagnostic data. The pooled SEN, SPE, PLR, NLR, DOR and area under the sROC curve of DKK1 for the diagnosis of HCC were 0.65 (95% confidence interval [95% CI], 0.52-0.76), 0.94 (95% CI, 0.82-0.98), 10.1 (95% CI, 3.68-27.74), 0.38 (95% CI, 0.28-0.51), 26.90 (95% CI, 10.45-69.19) and 0.84 (95% CI, 0.81-0.87), respectively. Three articles (5 studies) provided DKK1 and α-fetoprotein (AFP) combined test data. The pooled SEN, SPE, PLR, NLR, DOR and area under the sROC curve of combined detection for the diagnosis of HCC were 0.81 (95% CI, 0.76-0.85), 0.85 (95% CI, 0.78-0.91), 5.52 (95% CI, 3.76-8.10), 0.22 (95% CI, 0.19-0.27), 24.60 (95% CI, 17.69-34.19) and 0.88 (95% CI, 0.85-0.91), respectively. Conclusion Both DKK1 and DKK1 plus AFP had high diagnostic accuracy for diagnosis of HCC.


Cancers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 5253
Author(s):  
Md. Mohaimenul Islam ◽  
Tahmina Nasrin Poly ◽  
Bruno Andreas Walther ◽  
Ming-Chin Lin ◽  
Yu-Chuan (Jack) Li

Gastric cancer (GC) is one of the most newly diagnosed cancers and the fifth leading cause of death globally. Identification of early gastric cancer (EGC) can ensure quick treatment and reduce significant mortality. Therefore, we aimed to conduct a systematic review with a meta-analysis of current literature to evaluate the performance of the CNN model in detecting EGC. We conducted a systematic search in the online databases (e.g., PubMed, Embase, and Web of Science) for all relevant original studies on the subject of CNN in EGC published between January 1, 2010, and March 26, 2021. The Quality Assessment of Diagnostic Accuracy Studies-2 was used to assess the risk of bias. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Moreover, a summary receiver operating characteristic curve (SROC) was plotted. Of the 171 studies retrieved, 15 studies met inclusion criteria. The application of the CNN model in the diagnosis of EGC achieved a SROC of 0.95, with corresponding sensitivity of 0.89 (0.88–0.89), and specificity of 0.89 (0.89–0.90). Pooled sensitivity and specificity for experts endoscopists were 0.77 (0.76–0.78), and 0.92 (0.91–0.93), respectively. However, the overall SROC for the CNN model and expert endoscopists was 0.95 and 0.90. The findings of this comprehensive study show that CNN model exhibited comparable performance to endoscopists in the diagnosis of EGC using digital endoscopy images. Given its scalability, the CNN model could enhance the performance of endoscopists to correctly stratify EGC patients and reduce work load.


2018 ◽  
Vol 51 (6) ◽  
pp. 2631-2646 ◽  
Author(s):  
Jiangyue Qin ◽  
Ni Zeng ◽  
Ting Yang ◽  
Chun Wan ◽  
Lei Chen ◽  
...  

Background/Aims: Recently, many studies have demonstrated that various tumor-associated autoantibodies have been detected in early stages of lung cancer. Therefore, we conducted a meta-analysis to comprehensively evaluate available evidence on the diagnostic value of autoantibodies against tumor-associated antigens in lung cancer. Methods: We systematically searched PubMed, Scopus, Web of Science and other databases through 23 March 2018. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2. We used the bivariate mixed-effect models to calculate pooled values of sensitivity, specificity, positive likelihood ratios, negative likelihood ratios, diagnostic odds ratios and associated 95% confidence intervals. Summary receiver operating characteristic (SROC) curves were used to summarize overall test performance. Deek’s funnel plot was used to detect publication bias. Results: Review of 468 candidate articles identified fifty-three articles with a total of 11,515 patients for qualitative review and meta-analysis. Pooled sensitivity, specificity and area under the SROC curve were as follows for tumor-associated autoantibodies against the following proteins: p53, 0.19, 0.98, 0.82; NY-ESO-1, 0.17, 0.98, 0.90; Survivin, 0.19, 0.99, 0.96; c-myc, 0.14, 0.98, 0.45; Cyclin B1, 0.18, 0.98, 0.91; GBU4-5, 0.07, 0.98, 0.91; CAGE, 0.14, 0.98, 0.90; p16, 0.08, 0.97, 0.91; SOX2, 0.14, 0.99, 0.93; and HuD, 0.17, 0.99, 0.82. Conclusion: Each tumor-associated autoantibody on its own showed excellent diagnostic specificity for lung cancer but inadequate sensitivity. Our results suggest that combinations or panels of tumor-associated autoantibodies may provide better sensitivity for diagnosing lung cancer, and the diagnostic accuracy of tumor-associated autoantibodies should be validated in more studies.


2015 ◽  
Vol 25 (1) ◽  
pp. 18-23 ◽  
Author(s):  
Zhaolian Lu ◽  
Yingjian Chen ◽  
Zhide Hu ◽  
Chengjin Hu

ObjectiveThis study aimed to assess the diagnostic value of lysophosphatidic acid (LPA) in ovarian cancer.MethodsA systematic review of related studies was performed; sensitivity, specificity, and other measures about the accuracy of serum LPA in the diagnosis of ovarian cancer were pooled using random-effects models. Summary receiver operating characteristic curve analysis was used to summarize the overall test performance.ResultsSix studies involving 363 patients with ovarian cancer and 273 healthy control women met the inclusion criteria. The summary estimates for LPA in diagnosing ovarian cancer in the included studies were as follows: sensitivity, 0.94 [95% confidence interval (CI), 0.91–0.96]; specificity, 0.88 (95% CI, 0.83–0.91); and diagnostic odds ratio, 141.59 (95% CI, 52.1–384.63). The area under the curve and Q value for summary receiver operating characteristic curves were 0.97 and 0.92, respectively.ConclusionsThe LPA assay showed high accuracy and sensitivity for the diagnosis of ovarian cancer. The present study was limited by the small number of available studies and sample size; therefore, additional studies with a better design and larger samples are needed to further assess the diagnostic accuracy of LPA.


Sign in / Sign up

Export Citation Format

Share Document