scholarly journals Short-term rates of radiolucency after primary total shoulder arthroplasty using a cementless metal-backed pegged polyethylene glenoid

2018 ◽  
Vol 12 (1_suppl) ◽  
pp. 4-10
Author(s):  
Khalid Al-Hourani ◽  
James R Smith ◽  
Mark A Crowther ◽  
Partha Sarangi ◽  
Philip A McCann

Background Total shoulder arthroplasty has shown good clinical efficacy in treating primary and secondary degenerative conditions of the glenohumeral joint. Glenoid loosening, however, remains the commonest cause of failure. The purpose of this study was to investigate the rate of radiographic periprosthetic lucency associated with the use of an uncemented, pegged, metal-backed polyethylene glenoid component. Materials and methods A retrospective, single-centre study using the Epoca (Synthes, Paoli, Pennsylvania) metal-backed glenoid component. Operations were performed by two experienced consultant upper limb surgeons. Radiographs were analysed for immediate post-operative component seating and periprosthetic radiolucent lines at predefined regular post-operative intervals. Intra- and inter-observer reliability was assessed to improve validity of results. Results Mean age and follow-up was 72 (48–91) years and 2.5 years (2–5), respectively. Main indications for total shoulder arthroplasty were primary osteoarthritis, rheumatoid arthritis, revision for failed hemi-arthroplasty and acute fracture. Ninety-six per cent of components were completely seated post-operatively. Fifty-four (95%) of the 57 shoulders had no periprosthetic radiolucent lines at most recent follow-up. Complete post-operative glenoid seating was significantly associated with the absence of later periprosthetic radiolucency (p < 0.01). Conclusion This study reports low early radiolucency rates with the pegged, uncemented, metal-backed polyethylene glenoid prosthesis used. Excellent post-operative glenoid seating is associated with a significantly lower rate of radiolucency. Longer follow-up data are required to confirm these early promising results. Level of evidence: Therapeutic, level IV.

2020 ◽  
pp. 175857321990112
Author(s):  
Nicholas J Murray ◽  
Khalid Al-Hourani ◽  
Mark AA Crowther ◽  
Partha P Sarangi ◽  
Philip A McCann

Background Total shoulder arthroplasty is an established treatment with the commonest cause of failure loosening of the glenoid component. Hydroxyapatite metal-backed glenoid components could offer better survivorship due to improved fixation. The aim of this study was to investigate periprosthetic radiolucency rates associated with an uncemented, metal-backed polyethylene glenoid component with medium-term results. Methods A single centre retrospective study examining radiological outcomes of the Epoca metal-backed glenoid component. Radiographs were analysed for post-operative adequacy of glenoid seating and radiographs at follow-up assessed for periprosthetic lucencies and any revision procedures were recorded. Results Forty-one patients were followed up with a mean follow-up time of 5.5 years (3–8 years). Primary indication for total shoulder arthroplasty was osteoarthritis (80%). Mean age was 69 years (53–86 years). Ninety-five per cent of glenoid components were completely seated. At follow-up six patients had undergone revision (14.6%). Thirty of the remaining patients (86%) did not demonstrate any radiolucency on follow-up radiographs. Complete glenoid seating post-operatively was associated with lower rate of subsequent radiolucency and revision (P < 0.01). Conclusion Low rates of radiolucency at medium-term follow-up with an uncemented metal-backed glenoid, however significant rates of revision. Complete seating of the glenoid component was associated with lower rates of radiolucency and revision.


Author(s):  
Thay Q. Lee ◽  
Mark Schamblin ◽  
Bruce Y. Yang ◽  
Michelle H. McGarry ◽  
Ranjan Gupta

Glenohumeral arthroplasty as well as hemiarthroplasty, although providing adequate pain relief, has not shared in the success of similar joint replacement procedures such as total knee arthroplasty or total hip arthroplasty. Short comings of this procedure include a decreased range of motion postoperatively as well as increased incidents of glenoid component loosening in total shoulder procedures. This is especially a problem in the end ranges of motion where eccentric loading of the glenoid component are thought to occur. The purpose of this study was to quantify the glenohumeral joint forces before and after bipolar shoulder hemiarthroplasty and total shoulder arthroplasty for positions simulating overhead activities and commonly relied upon by the wheelchair dependent individual.


2020 ◽  
pp. 175857322091682
Author(s):  
John-Rudolph H Smith ◽  
Darby A Houck ◽  
Jessica A Hart ◽  
Jonathan T Bravman ◽  
Rachel M Frank ◽  
...  

Background The purpose of this study was to describe the clinical outcomes following bilateral total shoulder arthroplasty (TSA). Methods A systematic search of the PubMed, Embase, and Cochrane Library databases following PRISMA guidelines was performed. English-language literature published from 2010 to 2018 analyzing bilateral TSA (anatomic and/or reverse) with a minimum one-year follow-up was reviewed by two independent reviewers. Study quality was evaluated with the Modified Coleman Methodology Score and the methodological index for non-randomized studies score. Results Eleven studies (1 Level II, 3 Level III, 7 Level IV) with 292 patients were included. Two studies reported on bilateral anatomic TSA ( n = 54), six reported on bilateral reverse TSA (RTSA; n = 168), two reported on anatomic TSA with contralateral RTSA (TSA/RTSA; n = 31), and one compared bilateral anatomic TSA ( n = 26) and bilateral RTSA ( n = 13). Among studies, mean revision rate ranged from 0% to 10.53% and mean complication rate ranged from 4.9% to 31.3%. At final follow-up, patients experienced significant overall improvements in range of motion and patient-reported outcome score measurements. However, bilateral anatomic TSA resulted in greater improvements in external rotation compared to bilateral RTSA. Overall patient satisfaction was 91.0%. Conclusion The available data indicate that bilateral TSA allows for functional and pain improvements and result in high patient satisfaction. Level of evidence IV.


2018 ◽  
Vol 2 ◽  
pp. 247154921775047
Author(s):  
Joaquin Sanchez-Sotelo ◽  
Ngoc Tram V Nguyen ◽  
Mark Morrey

Background: High rates of radiographic loosening have been reported with various glenoid designs. Many available designs sacrifice most of the bone at the central portion of the glenoid vault, creating large areas of deficiency when revision becomes necessary. The purpose of this study was to report the 2- to 5-year outcome of shoulder arthroplasty using a bone-preserving all-polyethylene glenoid components with self-pressurizing pegs. Methods: Between August 2011 and December 2014, 202 consecutive anatomic total shoulder arthroplasties (TSAs) were performed by a single surgeon with implantation of a self-pressurizing cemented pegged glenoid component in 190 patients (12 patients had both shoulders replaced). Patients were followed up prospectively and evaluated for pain, motion, strength, American Shoulder and Elbow Surgeons (ASES) scores, and radiographic changes. The mean follow-up time was 2.7 (2–5) years. Results: TSA improved pain and function reliably. At the most recent follow-up, 94% of the shoulders had no or mild pain. Motion included 154 ± 25° of elevation, 68 ± 18° of external rotation, and median internal rotation to T10 (range, iliac crest to T4). The most recent average ASES score was 82 ± 15 points. Early postoperative radiographs showed no radiolucent lines. No humeral or glenoid component was considered radiographically loose at the most recent follow-up. Complications requiring reoperation included subscapularis insufficiency (4), posterior instability (2), deep infection (1), stiffness (1), and a painful loose body (1). No components were revised for loosening. Conclusions: Anatomic TSA using a cemented bone-preserving all-polyethylene pegged self-pressurizing glenoid component provided satisfactory clinical outcomes and survival at 2 to 5 years.


2018 ◽  
Vol 100-B (4) ◽  
pp. 485-492 ◽  
Author(s):  
M. O. Gauci ◽  
N. Bonnevialle ◽  
G. Moineau ◽  
M. Baba ◽  
G. Walch ◽  
...  

Aims Controversy about the use of an anatomical total shoulder arthroplasty (aTSA) in young arthritic patients relates to which is the ideal form of fixation for the glenoid component: cemented or cementless. This study aimed to evaluate implant survival of aTSA when used in patients aged < 60 years with primary glenohumeral osteoarthritis (OA), and to compare the survival of cemented all-polyethylene and cementless metal-backed glenoid components. Materials and Methods A total of 69 consecutive aTSAs were performed in 67 patients aged < 60 years with primary glenohumeral OA. Their mean age at the time of surgery was 54 years (35 to 60). Of these aTSAs, 46 were undertaken using a cemented polyethylene component and 23 were undertaken using a cementless metal-backed component. The age, gender, preoperative function, mobility, premorbid glenoid erosion, and length of follow-up were comparable in the two groups. The patients were reviewed clinically and radiographically at a mean of 10.3 years (5 to 12, sd 26) postoperatively. Kaplan–Meier survivorship analysis was performed with revision as the endpoint. Results A total of 26 shoulders (38%) underwent revision surgery: ten (22%) in the polyethylene group and 16 (70%) in the metal-backed group (p < 0.0001). At 12 years’ follow-up, the rate of implant survival was 74% (sd 0.09) for polyethylene components and 24% (sd 0.10) for metal-backed components (p < 0.0002). Glenoid loosening or failure was the indication for revision in the polyethylene group, whereas polyethylene wear with metal-on-metal contact, instability, and insufficiency of the rotator cuff were the indications for revision in the metal-backed group. Preoperative posterior subluxation of the humeral head with a biconcave/retroverted glenoid (Walch B2) had an adverse effect on the survival of a metal-backed component. Conclusion The survival of a cemented polyethylene glenoid component is three times higher than that of a cementless metal-backed glenoid component ten years after aTSA in patients aged < 60 years with primary glenohumeral OA. Patients with a biconcave (B2) glenoid have the highest risk of failure. Cite this article: Bone Joint J 2018;100-B:485–92.


Joints ◽  
2021 ◽  
Author(s):  
Riccardo Luigi Alberio ◽  
Marco Landrino ◽  
Paolo Fornara ◽  
Federico Alberto Grassi

Abstract Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant–Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26–84) and 44 months (range 26–66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.


2021 ◽  
pp. 175857322110588
Author(s):  
William R Aibinder ◽  
Fares Uddin ◽  
Ryan T Bicknell ◽  
Ryan Krupp ◽  
Markus Scheibel ◽  
...  

Background Finite element analysis has suggested that stemless implants may theoretically decrease stress shielding. The purpose of this study was to assess the radiographic proximal humeral bone adaptations seen following stemless anatomic total shoulder arthroplasty. Methods A retrospective review of 152 prospectively followed stemless total shoulder arthroplasty utilizing a single implant design was performed. Anteroposterior and lateral radiographs were reviewed at standard time points. Stress shielding was graded as mild, moderate, and severe. The effect of stress shielding on clinical and functional outcomes was assessed. Also, the influence of subscapularis management on the occurrence of stress shielding was determined. Results At 2 years postoperatively, stress shielding was noted in 61 (41%) shoulders. A total of 11 (7%) shoulders demonstrated severe stress shielding with 6 occurring along the medial calcar. There was one instance of greater tuberosity resorption. At the final follow-up, no humeral implants were radiographically loose or migrated. There was no statistically significant difference in clinical and functional outcomes between shoulders with and without stress shielding. Patients undergoing a lesser tuberosity osteotomy had lower rates of stress shielding, which was statistically significant ( p = 0.021) Discussion Stress shielding does occur at higher rates than anticipated following stemless total shoulder arthroplasty, but was not associated with implant migration or failure at 2 years follow-up. Level of evidence IV, Case series.


2021 ◽  
pp. 155633162110408
Author(s):  
Ahmed Haleem ◽  
Phelopater Sedrak ◽  
Chetan Gohal ◽  
George S. Athwal ◽  
Moin Khan ◽  
...  

Background: Hybrid glenoid components in total shoulder arthroplasty (TSA) utilize both polyethylene and metal components to provide short-term stability and long-term biologic fixation through bone ingrowth. Questions/Purpose: We sought to systematically review the literature for studies that assessed outcomes of TSA performed using hybrid glenoid components. Methods: PubMed, Medline, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Embase were searched systematically for articles measuring clinical and patient-reported outcomes and rates of complication and revision following TSA using a hybrid glenoid component. Results: Seven studies with 593 shoulders were included in this review. The mean age of patients was 65 ± 1 years, and 46% of the population was male. Mean follow-up was 50 months (4.2 years). The overall complication rate was 7% and rate of revision was 2.5%; glenoid radiolucency was present in 33% of shoulders at mean follow-up of 50 months. Mean improvements in forward elevation, external rotation, internal rotation score, and abduction were 49°, 28°, 2 points, and 42°, respectively. Mean improvements in Constant, American Shoulder and Elbow Surgeons (ASES), and University of California, Los Angeles (UCLA) scores were 36 points, 52 points, and 17 points, respectively. Conclusion: Our review found that TSA using hybrid glenoid components results in low rates of complication and revision at early follow-up. Long-term studies are warranted to understand more fully the role of hybrid glenoid components in TSA.


2021 ◽  
Vol 10 (24) ◽  
pp. 5773
Author(s):  
Maciej J. K. Simon ◽  
Helen Crofts ◽  
Treny Sasyniuk ◽  
Kayla Johnston ◽  
Derek Plausinis ◽  
...  

Background: Malpositioning of the glenoid component in total shoulder arthroplasty (TSA) remains the primary source of loosening. The purpose of this study is firstly, to quantify postoperative glenoid component position in patients having a TSA and secondly, to explore whether glenoid component radiolucency is associated with glenoid position, clinical outcomes and patient-reported measures in the short-term (two year) follow-up period. Methods: This study was a sub-study of a larger clinical trial that included patients who underwent a TSA and who were randomized into two different glenoid types with a minimum two-year follow-up period. Post-operative radiographic assessments (six weeks and two years) were used to measure glenoid component position (version, inclination, offset) and humeral head centering anterior–posterior (AP) and superior–inferior (SI), and to assess glenoid component radiolucent scoring (modified Lazarus). Pre-operative X-rays were used to measure glenoid version, inclination and Walch classification. Patient-reported measures (PROMs) included the EQ-5D health slider and the Western Ontario Osteoarthritis (WOOS) and American Shoulder and Elbow Surgeons (ASES) score and were captured at baseline and two years postoperative. Clinical outcomes including range of motion and complications were also documented. Statistical analysis included t-tests and regression modeling. Results: Ninety-one patients with an average age of 69.9 ± 6.2 years were included in this study. Glenoid component position improved significantly in version (−19.4 ± 8.6° to −17.7 ± 8.5°; p < 0.045) and inclination (11.5 ± 7.1° to 5.9 ± 6.3°; p < 0.00001) from preoperative to six weeks postoperative. Glenoid component offset in SI and humeral head centering in AP remained unchanged throughout the follow-up. Radiolucency (Lazarus classification) was recorded in 21 cases (17.3%) with a Lazarus score of 1 (15 cases) and 2 (6 cases). The EQ-5D health slider, WOOS and ASES, and ROM confirmed continuous improvements from the preoperative scores to the two-year follow-up (p < 0.05). Regression models showed no correlation between glenoid component radiolucency at two years and the postoperative week six glenoid component position; however, female gender was a significant variable. Conclusion: Glenoid component changes from its original native glenoid were observed following TSA. Glenoid inclination was improved more than version from baseline, and the humeral head remained well-centered in AP and SI at two years. Radiolucency of the glenoid at two years is not negatively associated with PROMs or component position; however, female gender was identified as a significant predictor and warrants further investigation. Complications are not associated with glenoid position or radiolucency, but longer-term follow-up is required.


2020 ◽  
pp. 175857322094416
Author(s):  
Michael-Alexander Malahias ◽  
Lazaros Kostretzis ◽  
Ioannis Gkiatas ◽  
Efstathios Chronopoulos ◽  
Emmanouil Brilakis ◽  
...  

Background Several articles have been published reporting on the clinical performance of a novel pegged, all-polyethylene glenoid component design which features a central peg, circumferentially fluted, interference-fit peg for tissue integration and three small peripheral pegs for cementing. However, no systematic review exists to this date. Methods The US National Library of Medicine (PubMed/MEDLINE), EMBASE, and the Cochrane Database of Systematic Reviews were queried for publications up to May 2020. Results Overall, 13 articles were included for analysis (560 operated shoulders, range of mean follow-up: 2–6 years). The survival rate was 98.2% (550 out of 560 cases), while the rate of aseptic loosening was 0.2% (1 out of 560 cases). There were 139 cases (out of 399 reported; 34.1%) with peri-glenoid radiolucency, and 35 cases (out of 223 reported; 15.7%) of asymptomatic central peg osteolysis, with 1 of them undergoing revision. Conclusions There was fair quality of evidence to show that partially cemented all-polyethylene pegged bone-ingrowth glenoid components produce promising results, with a low revision rate in the short- to medium-term follow-up. Nevertheless, this analysis showed high rates of both radiolucency of the glenoid component and osteolysis around the central peg which raise concern for potential failure of this glenoid component in the long-term follow-up. Level of evidence Systematic review, IV.