Development of Simultaneous Analysis Method for Multi-Compounds Content of New Shilajit Using HPLC-UV and the Cognitive Enhancing Effect: Mongolian Shilajit

2021 ◽  
Vol 16 (7) ◽  
pp. 1934578X2110304
Author(s):  
SukJin Lee ◽  
HyeSung Ryu ◽  
WanKyunn Whang

Shilajit has a longstanding use as an anti-aging and memory enhancing drug. It is known to have excellent anti-bacterial effects and is believed to be effective for cognitive enhancement, but is difficult to standardize because of the lack of quality control standards. This study, for the first time, proposes a quality control standard using a simultaneous analytical method for the drug’s multi-compound content using high-performance liquid chromatography-ultraviolet detection (HPLC-UV) as an aid for the internationalization of Mongolian Shilajit. Phenolic compounds 1-6 were isolated from Mongolian Shilajit extract using bioassay-guided isolation, and the isolated compounds were evaluated for cognitive-related anti-Alzheimer’s disease (AD) activities using 1,1-diphenyl-2-picrylhydrazyl (DPPH) free radical-scavenging, acetylcholinesterase (AChE), butyrylcholinesterase (BChE), β-site amyloid precursor protein-cleaving enzyme 1 (BACE1), and advanced glycation end-product (AGE) formation assays. The isolated compounds showed good effects for each activity. In addition, the isolated compounds were successfully quantified using a validated quantitative HPLC analysis method. As a result, the isolated compounds were suggested as standard marker compounds for Mongolian Shilajit. Also, we proved that the original material of Mongolian Shilajit is a lichen named Xanthoparmelia somloensis (Gyel.) Hale using HPLC-UV, ultra-high-performance liquid chromatography-electrospray ionization/hybrid linear trap-quadruple-orbitrap-high-resolution mass spectrometry (UHPLC-ESI/LTQ-HRMS).

2021 ◽  
Vol 11 (11) ◽  
pp. 4819
Author(s):  
Chang-Seob Seo ◽  
Mee-Young Lee

Insamyangpye–tang (ISYPT) is a traditional medicinal formula comprised of 13 herbs and has been used in East Asia to treat lung-related diseases. However, to our knowledge, no method of analysis for its quality control has been reported. In this study, a method of analysis for quality control of ISYPT was developed using high-performance liquid chromatography. Chromatographic separation, analysis, and assay verification were performed with a distilled water–acetonitrile mobile phase system, both containing 0.1% (v/v) trifluoroacetic acid, and a Gemini C18 analytical column (4.6 mm × 250 mm, 5 mm) using authentic standards for eight marker compounds. These marker constituents were detected simultaneously at 0.09–5.95 mg/g. The analysis method developed can be used for basic quality control of ISYPT.


Molecules ◽  
2020 ◽  
Vol 25 (20) ◽  
pp. 4625
Author(s):  
Ye-Ji Kang ◽  
Hyeon-Cheol Jeong ◽  
Tae-Eun Kim ◽  
Kwang-Hee Shin

Metformin is the first-line medicine for the treatment of type 2 diabetes. Drug interactions between metformin and other drugs, food, or beverages cannot only cause changes in the pharmacokinetic profiles but also affect the efficacy of metformin. The purpose of this study was to develop a rapid and reliable bioanalytical method for the detection of plasma metformin concentration in humans. To remove interfering substances in plasma, acidified acetonitrile (acetonitrile containing 0.1% formic acid) was added to samples. Ultra-high-performance liquid chromatography (UHPLC) coupled with high resolution mass spectrometry (HRMS) was used to analyze metformin and its internal standard (metformin-d6). Analyte separation was performed on a BEH HILIC analytical column (100 × 2.1 mm, 1.7 μm) using a gradient elution of 0.1% formic acid (A) and acetonitrile with 0.1% formic acid (B). The total chromatographic run time was 2 min. The developed method was validated for its linearity, accuracy and precision, selectivity (signal of interfering substance; analyte, lower limit of quantification (LLOQ) ≤ 20%; IS, IS ≤ 5%), sensitivity (LLOQ, 5 ng/mL; S/N ratio ≥ 10), stability (low quality control (LQC, 15 ng/mL), 2.95–14.19%; high quality control (HQC, 1600 ng/mL), −9.49–15.10%), dilution integrity (diluted QC (4000 ng/mL); 10-folds diluted QC (400 ng/mL); 5-folds diluted QC (800 ng/mL); accuracy, 81.30–91.98%; precision, ≤4.47%), carry-over (signal of double blank; analyte, LLOQ ≤20%; IS, IS ≤5%), and matrix effect (LQC, 10.109%; HQC, 12.271%) under various conditions. The constructed calibration curves were shown linear in the concentration range of 5–2000 ng/mL, with within- and between-run precision values of <8.19% and accuracy in the range of 91.13–105.25%. The plasma metformin concentration of 16 healthy subjects was successfully measured by applying the validated bioanalytical method.


Sign in / Sign up

Export Citation Format

Share Document