scholarly journals High-Throughput Analysis of Fluorescently Labeled N-Glycans Derived from Biotherapeutics Using an Automated LC-MS-Based Solution

2020 ◽  
Vol 25 (4) ◽  
pp. 380-387 ◽  
Author(s):  
Ximo Zhang ◽  
Corey E. Reed ◽  
Robert E. Birdsall ◽  
Ying Qing Yu ◽  
Weibin Chen

Protein glycosylation can impact the efficacy and safety of biotherapeutics and therefore needs to be well characterized and monitored throughout the drug product life cycle. Glycosylation is commonly assessed by fluorescent labeling of released glycans, which provides comprehensive information of the glycoprofile but can be resource-intensive regarding sample preparation, data acquisition, and data analysis. In this work, we evaluate a comprehensive solution from sample preparation to data reporting using a liquid chromatography–mass spectrometry (LC-MS)-based analytical platform for increased productivity in released glycan analysis. To minimize user intervention and improve assay robustness, a robotic liquid handling platform was used to automate the release and labeling of N-glycans within 2 h. To further increase the throughput, a 5 min method was developed on a liquid chromatography–fluorescence–mass spectrometry (LC-FLR-MS) system using an integrated glycan library based on retention time and accurate mass. The optimized method was then applied to 48 released glycan samples derived from six batches of infliximab to mimic comparability testing encountered in the development of biopharmaceuticals. Consistent relative abundance of critical species such as high mannose and sialylated glycans was obtained for samples within the same batch (mean percent relative standard deviation [RSD] = 5.3%) with data being acquired, processed, and reported in an automated manner. The data acquisition and analysis of the 48 samples were completed within 6 h, which represents a 90% improvement in throughput compared with conventional LC-FLR-based methods. Together, this workflow facilitates the rapid screening of glycans, which can be deployed at various stages of drug development such as process optimization, bioreactor monitoring, and clone selections, where high-throughput and improved productivity are particularly desired.

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Junmei Ma ◽  
Qiang Li ◽  
Sufang Fan ◽  
Liangna He ◽  
Lei Sun ◽  
...  

A ultrahigh performance liquid chromatography coupled with quadrupole-time of flight mass spectrometry (UPLC-Q-TOF/MS) method was developed for simultaneous determination of 8 endogenous alkaloid compounds in Boletus. Boletus samples were extracted by 50% (V/V) methanol-water solution, then separated by CORTECS UPLC HILIC column using a binary solvent system by gradient elution. The analytes were determined by Q-TOF/MS in TOF MS and information dependent acquisition (IDA)-MS/MS mode. The results showed that mass accuracy error of the 8 endogenous alkaloids were lower than 5.0 × 10−6, good linear relationship was got in range of 0.2–500 μg/L, and correlation coefficient was higher than 0.9990. The limit of detection was in the range of 0.002–0.100 mg/kg and the limit of quantification was in the range of 0.004–0.200 mg/kg. Recovery of the method was in range of 80.1%–101.5% with spike levels of 0.004–2.00 mg/kg, relative standard deviations were lower than 10%. The method was simple, specific, and reliable. It could be used for the rapid screening and quantitative analysis of 8 endogenous alkaloids in Boletus.


2020 ◽  
Vol 16 (4) ◽  
pp. 355-363 ◽  
Author(s):  
Tao Zhang ◽  
Katarina Madunić ◽  
Stephanie Holst ◽  
Jing Zhang ◽  
Chunsheng Jin ◽  
...  

The developed workflow allows high throughput sample preparation for glycomics analysis.