scholarly journals Doppler ultrasound and contrast-enhanced ultrasound in detection of stent stenosis after iliac vein stenting

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hong Liu ◽  
Jing Wang ◽  
Yu Zhao ◽  
Zheng Chen ◽  
Dong Wang ◽  
...  

Abstract Background To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method. Methods Patients with iliac vein obstructive disease treated with nitinol stents (Smart Control, Cordis, USA) between January 2016 and December 2017 were consecutively included in this study. DUS, CEUS, and MDCTV were carried out in all patients within one week of each other at 1 year post stenting to investigate the presence of stent compression and in-stent restenosis (ISR). Results The study included 139 patients (87 females; mean age 58 ± 15 years). For detecting stent compression, the kappa coefficient between the ultrasound modality of gray-scale imaging and MDCTV was 0.901, indicating very good agreement between these two modalities. ISR was detected in 50, 61, and 65 patients by DUS, CEUS, and MDCTV, respectively. DUS and CEUS (kappa = 0.449) and DUS and MDCTV (kappa = 0.516) had moderate agreement for ISR diagnosis, while for which CEUS and MDCTV (kappa 0.884) had very good agreement. The sensitivity and specificity of DUS and CEUS for diagnosing ISR were 63.1% and 90.8%, 87.8% and 97.3%, respectively. Conclusions CEUS is probably superior to DUS in terms of diagnostic accuracy for the follow-up of patients with iliac vein stent stenosis.

2020 ◽  
Author(s):  
Hong Liu ◽  
Jing Wang ◽  
Yu. Zhao ◽  
Zheng Chen ◽  
Dong Wang ◽  
...  

Abstract Background: To compare the diagnostic accuracy of Doppler ultrasound (DUS) with contrast-enhanced ultrasound (CEUS) for detection of iliac vein stent stenosis using multidetector computed tomography venography (MDCTV) as the reference method.Methods: Patients with iliac vein obstructive disease treated with nitinol stents between January 2016 and December 2017 were consecutively included in this study. DUS, CEUS, and MDCTV were carried out in all patients within one week of each other at one year post stenting to investigate the presence of stent compression and in-stent restenosis (ISR). Results: The study included 139 patients (87 females; mean age 58 ± 15 years). For detecting stent compression, the kappa coefficient between the ultrasound modality of gray-scale imaging and MDCTV was 0.901, indicating very good agreement between these two modalities. ISR was detected in 50, 61, and 65 patients by DUS, CEUS, and MDCTV, respectively. DUS and CEUS (kappa=0.449) and DUS and MDCTV (kappa=0.516) had moderate agreement for ISR diagnosis, while for which CEUS and MDCTV (kappa 0.884) had very good agreement. The sensitivity, specificity, positive and negative predictive values of DUS and CEUS for diagnosing ISR were 63.1% and 90.8%, 87.8% and 97.3%, 82.0% and 96.7%, and 73.0% and 92.3%, respectively.Conclusions: CEUS is superior to DUS in terms of diagnostic accuracy for the follow-up of patients with iliac vein stent stenosis.


Diagnostics ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 1244
Author(s):  
Sonja Schwarz ◽  
Dirk-André Clevert ◽  
Michael Ingrisch ◽  
Thomas Geyer ◽  
Vincent Schwarze ◽  
...  

Background: To evaluate the diagnostic accuracy of quantitative perfusion parameters in contrast-enhanced ultrasound to differentiate malignant from benign liver lesions. Methods: In this retrospective study 134 patients with a total of 139 focal liver lesions were included who underwent contrast enhanced ultrasound (CEUS) between 2008 and 2018. All examinations were performed by a single radiologist with more than 15 years of experience using a second-generation blood pool contrast agent. The standard of reference was histopathology (n = 60), MRI or CT (n = 75) or long-term CEUS follow up (n = 4). For post processing regions of interests were drawn both inside of target lesions and the liver background. Time–intensity curves were fitted to the CEUS DICOM dataset and the rise time (RT) of contrast enhancement until peak enhancement, and a late-phase ratio (LPR) of signal intensities within the lesion and the background tissue, were calculated and compared between malignant and benign liver lesion using Student’s t-test. Quantitative parameters were evaluated with respect to their diagnostic accuracy using receiver operator characteristic curves. Both features were then combined in a logistic regression model and the cumulated accuracy was assessed. Results: RT of benign lesions (14.8 ± 13.8 s, p = 0.005), and in a subgroup analysis, particular hemangiomas (23.4 ± 16.2 s, p < 0.001) differed significantly to malignant lesions (9.3 ± 3.8 s). The LPR was significantly different between benign (1.59 ± 1.59, p < 0.001) and malignant lesions (0.38 ± 0.23). Logistic regression analysis with RT and LPR combined showed a high diagnostic accuracy of quantitative CEUS parameters with areas under the curve of 0.923 (benign vs. malignant) and 0.929 (hemangioma vs. malignant. Conclusions: Quantified CEUS parameters are helpful to differentiate malignant from benign liver lesions, in particular in case of atypical hemangiomas.


Author(s):  
Yanling Chen ◽  
Wenping Wang

AIM: To explore the diagnostic ability of contrast-enhanced ultrasound (CEUS) in distinguishing intrahepatic cholangiocarcinoma (ICC) from hepatocellular carcinoma (HCC). MATERIALS AND METHODS: PubMed, EMBASE, Cochrane Library, and Web of Science were systematically searched for studies reporting the diagnostic accuracy of CEUS in differentiating ICC from HCC. The diagnostic ability of CEUS was assessed based on the pooled sensitivity, specificity, diagnostic odds ratio (DOR), positive likelihood ratio (PLR), negative likelihood ratio (NLR) and area under the curve (AUC) with 95% confidence intervals (CIs). The methodologic quality was assessed by the QUADAS-2 tool. Subgroup analyses, meta-regression and investigation of publication bias were performed to identify the source of heterogeneity. RESULTS: A total of eight studies were included, consisting of 1,116 patients with HCC and 529 with ICC. The general diagnostic performance of CEUS in distinguishing ICC and HCC were as follows: pooled sensitivity, 0.92 (95% CI: 0.84–0.96); pooled specificity, 0.87 (95% CI: 0.79–0.92); pooled PLR, 7.1 (95% CI: 4.1–12.0); pooled NLR, 0.09 (95% CI: 0.05–0.19); pooled DOR, 76 (95% CI: 26–220) and AUC, 0.95(95% CI: 0.93–0.97). Different liver background may be a potential factor that influenced the diagnostic accuracy of CEUS according to the subgroup analysis, with the pooled DOR of 89.67 in the mixed liver background group and 46.87 in the cirrhosis group, respectively. Six informative CEUS features that may help differentiate HCC from ICC were extracted. The three CEUS features favoring HCC were arterial phase hyperenhancement(APHE), mild washout and late washout (>60s); the three CEUS favoring ICC were arterial rim enhancement, marked washout and early washout(<60s). No potential publication bias was observed. CONCLUSION: CEUS showed great diagnostic ability in differentiating ICC from HCC, which may be promising for noninvasive evaluation of these diseases.


2009 ◽  
Vol 41 (5) ◽  
pp. A6
Author(s):  
F. Piscaglia ◽  
V. Salvatore ◽  
A.G. Tewelde ◽  
G. Imbriaco ◽  
E. Sagrini ◽  
...  

2016 ◽  
Vol 22 ◽  
pp. 4755-4764 ◽  
Author(s):  
Yan Zhang ◽  
Yu-kun Luo ◽  
Ming-bo Zhang ◽  
Jie Li ◽  
Junlai Li ◽  
...  

2020 ◽  
Author(s):  
Xinyue Ge ◽  
Zhong-Kai Lan ◽  
Jing Chen ◽  
Shang-Yong Zhu

Aim: The study retrospectively analysed the accuracy of preoperative contrast-enhanced ultrasound (CEUS) in differenti-ating stage Ta-T1 or low-grade bladder cancer (BC) from stage T2 or high-grade bladder cancer. Material and methods: We systematically searched the literature indexed in PubMed, Embase, and the Cochrane Library for original diagnostic articles of bladder cancer. The diagnostic accuracy of CEUS was compared with cystoscopy and/or transurethral resection of bladder tumors (TURBT). The bivariate logistic regression model was used for data pooling, couple forest plot, diagnostic odds ratio (DOR) and summary receiver operating characteristic (SROC). Results: Five studies met the selection criteria; the overall number of reported bladder cancers patients were 436. The pooled-sensitivity (P-SEN), pooled-specificity (P-SPE), pooled-positive likelihood ratio (PLR+), pooled-negative likelihood ratio (PLR−), DOR, and area under the SROC curve were 94.0% (95%CI: 85%–98%), 90% (95%CI: 83%–95%), 9.5 (95%CI: 5.1–17.6), 0.06 (95%CI: 0.02–0.17), 147 (95%CI: 35–612) and 97% (95% CI: 95%–98%) respectively. Conclusion: CEUS reaches a high efficiency in discriminating Ta-T1 or low-grade bladder cancer from stage T2 or high-grade bladder cancer. It can be a promising method in patients to distinguish T staging and grading of bladder cancer because of its high sensitivity, specificity and diagnostic accuracy.