scholarly journals Clinical characteristics and outcomes of neonates with polymicrobial ventilator-associated pneumonia in the intensive care unit

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hsiao-Chin Wang ◽  
Ming-Horng Tsai ◽  
Shih-Ming Chu ◽  
Chen-Chu Liao ◽  
Mei-Yin Lai ◽  
...  

Abstract Background Ventilator associated pneumonia (VAP) caused by more than one microorganisms is not uncommon and may be potentially challenging, but the relevant data is scarce in ventilated neonates. We aimed to investigate the clinical characteristics and outcomes of polymicrobial VAP in the neonatal intensive care unit (NICU). Methods All neonates with definite diagnosis of VAP from a tertiary level neonatal intensive care unit (NICU) in Taiwan between October 2017 and September 2020 were prospectively observed and enrolled for analyses. All clinical features, therapeutic interventions and outcomes were compared between the polymicrobial VAP and monomicrobial VAP episodes. Multivariate regression analyses were used to find the independent risk factors for treatment failure. Results Among 236 episodes of neonatal VAP, 60 (25.4%) were caused by more than one microorganisms. Polymicrobial VAP episodes were more likely to be associated with multidrug-resistant pathogens (53.3% versus 34.7%, P = 0.014), more often occurred in later days of life and in neonates with prolonged intubation and underlying bronchopulmonary dysplasia. Otherwise most clinical characteristics of polymicrobial VAP were similar to those of monomicrobial VAP. The therapeutic responses and treatment outcomes were also comparable between these two groups, although modification of therapeutic antibiotics were significantly more common in polymicrobial VAP episodes than monomicrobial VAP episodes (63.3% versus 46.2%; P < 0.001). None of any specific pathogens was significantly associated with worse outcomes. Instead, it is the severity of illness, including presence of concurrent bacteremia, septic shock, and requirement of high-frequency oscillatory ventilator and underlying neurological sequelae that are independently associated with treatment failure. Conclusions Polymicrobial VAP accounted for 25.4% of all neonatal VAP in the NICU, and frequently occurred in neonates with prolonged intubation and underlying bronchopulmonary dysplasia. In our cohort, most clinical features, therapeutic responses and final outcomes of neonates with monomicrobial and polymicrobial VAP did not differ significantly.

2021 ◽  
Author(s):  
Hsiao-Chin Wang ◽  
Ming-Horng Tsai ◽  
Shih-Ming Chu ◽  
Chen-Chu Liao ◽  
Mei-Yin Lai ◽  
...  

Abstract Background: Ventilator associated pneumonia (VAP) caused by more than one microorganisms is not uncommon and may be potentially challenging, but the relevant data is scarce in ventilated neonates. We aimed to investigate the clinical characteristics and outcomes of polymicrobial VAP in the neonatal intensive care unit (NICU).Methods: All neonates with definite diagnosis of VAP from a tertiary level neonatal intensive care unit (NICU) in Taiwan between October 2017 and September 2020 were prospectively observed and enrolled for analyses. All clinical features, therapeutic interventions and outcomes were compared between the polymicrobial VAP and monomicrobial VAP episodes. Multivariate regression analyses were used to find the independent risk factors for treatment failure. Results: Among 236 episodes of neonatal VAP, 60 (25.4%) were caused by more than one microorganisms. Polymicrobial VAP episodes were more likely to be associated with multidrug-resistant pathogens (53.3% versus 34.7%, P = 0.014), more often occurred in later days of life and in neonates with prolonged intubation and underlying bronchopulmonary dysplasia. Otherwise most clinical characteristics of polymicrobial VAP were similar to those of monomicrobial VAP. The therapeutic responses and treatment outcomes were also comparable between these two groups, although modification of therapeutic antibiotics were significantly more common in polymicrobial VAP episodes than monomicrobial VAP episodes (63.3% versus 46.2%; P<0.001). None of any specific pathogens was significantly associated with worse outcomes. Instead, it is the severity of illness, including presence of concurrent bacteremia, septic shock, and requirement of high-frequency oscillatory ventilator and underlying neurological sequelae that are independently associated with treatment failure.Conclusions: Polymicrobial VAP accounted for 25.4% of all neonatal VAP in the NICU, and frequently occurred in neonates with prolonged intubation and underlying bronchopulmonary dysplasia. In our cohort, most clinical features, therapeutic responses and final outcomes of neonates with monomicrobial and polymicrobial VAP did not differ significantly.


2014 ◽  
Vol 36 (3) ◽  
pp. 287-293 ◽  
Author(s):  
Shih-Ming Chu ◽  
Mei-Chin Yang ◽  
Hsiu-Feng Hsiao ◽  
Jen-Fu Hsu ◽  
Reyin Lien ◽  
...  

ObjectiveTo investigate the impact of 1-week ventilator circuit change on ventilator-associated pneumonia and its cost-effectiveness compared with a 2-day change.DesignAn observational cohort study.SettingA tertiary level neonatal intensive care unit in a university-affiliated teaching hospital in Taiwan.PatientsAll neonates in the neonatal intensive care unit receiving invasive intubation for more than 1 week from July 1, 2011, through December 31, 2013.InterventionWe investigated the impact of 2 ventilator circuit change regimens, either every 2 days or 7 days, on ventilator-associated pneumonia of our cohort.Measurements and Main ResultsA total of 361 patients were maintained on mechanical ventilators for 13,981 days. The 2 groups did not differ significantly in any demographic characteristics. The rate of ventilator-associated pneumonia was comparable between the 2-day group and the 7-day group (8.2 vs 9.5 per 1,000 ventilator-days, P=.439). The durations of mechanical ventilation and hospital stay, and rates of bloodstream infection and mortality, were also comparable between the 2 groups. Switching from a 2-day to a 7-day change policy would save our neonatal intensive care unit a yearly sum of US $29,350 and 525 working hours.ConclusionDecreasing the frequency of ventilator circuit changes from every 2 days to once per week is safe and cost-effective in neonates requiring prolonged intubation for more than 1 week.Infect Control Hosp Epidemiol 2014;00(0): 1–7


2020 ◽  
Vol 112 (6) ◽  
pp. 515-522
Author(s):  
Nuriye Emiroğlu ◽  
Fatma Hilal Yılmaz ◽  
Ramazan Keçeci ◽  
Mehmet Yücel ◽  
Nazlı Dilay Gültekin ◽  
...  

Antibiotics ◽  
2020 ◽  
Vol 9 (11) ◽  
pp. 760
Author(s):  
Hsiao-Chin Wang ◽  
Chen-Chu Liao ◽  
Shih-Ming Chu ◽  
Mei-Yin Lai ◽  
Hsuan-Rong Huang ◽  
...  

It is unknown whether neonatal ventilator-associated pneumonia (VAP) caused by multidrug-resistant (MDR) pathogens and inappropriate initial antibiotic treatment is associated with poor outcomes after adjusting for confounders. Methods: We prospectively observed all neonates with a definite diagnosis of VAP from a tertiary level neonatal intensive care unit (NICU) in Taiwan between October 2017 and March 2020. All clinical features, therapeutic interventions, and outcomes were compared between the MDR–VAP and non-MDR–VAP groups. Multivariate regression analyses were used to investigate independent risk factors for treatment failure. Results: Of 720 neonates who were intubated for more than 2 days, 184 had a total of 245 VAP episodes. The incidence rate of neonatal VAP was 10.1 episodes/per 1000 ventilator days. Ninety-six cases (39.2%) were caused by MDR pathogens. Neonates with MDR–VAP were more likely to receive inadequate initial antibiotic therapy (51.0% versus 4.7%; p < 0.001) and had delayed resolution of clinical symptoms (38.5% versus 25.5%; p = 0.034), although final treatment outcomes were comparable with the non-MDR–VAP group. Inappropriate initial antibiotic treatment was not significantly associated with worse outcomes. The VAP-attributable mortality rate and overall mortality rate of this cohort were 3.7% and 12.0%, respectively. Independent risk factors for treatment failure included presence of concurrent bacteremia (OR 4.83; 95% CI 2.03–11.51; p < 0.001), septic shock (OR 3.06; 95% CI 1.07–8.72; p = 0.037), neonates on high-frequency oscillatory ventilator (OR 4.10; 95% CI 1.70–9.88; p = 0.002), and underlying neurological sequelae (OR 3.35; 95% CI 1.47–7.67; p = 0.004). Conclusions: MDR–VAP accounted for 39.2% of all neonatal VAP in the neonatal intensive care unit (NICU), but neither inappropriate initial antibiotics nor MDR pathogens were associated with treatment failure. Neonatal VAP with concurrent bacteremia, septic shock, and underlying neurological sequelae were independently associated with final worse outcomes.


2014 ◽  
Vol 20 (10) ◽  
pp. 627-630 ◽  
Author(s):  
Fumiko Kawanishi ◽  
Masami Yoshinaga ◽  
Michiyo Morita ◽  
Yuriko Shibata ◽  
Tomoyuki Yamada ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document