scholarly journals Case report: Fabrication of a dental implant guide based on tetrahedron positioning technology

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jie Lin ◽  
Zhenxiang Lin ◽  
Zhiqiang Zheng

Abstract Background Conventional static computer-assisted implant surgery (s-CAIS) requires special equipment, such as 3D printers or computer numerical control (CNC) lathes. We present a low-cost workflow for manufacturing dental implant guides based on tetrahedron positioning technology (TPT). The aim of this case report was to use a surgical guide technique for dental implant placement using tetrahedron positioning technology. Case presentation A 28-year-old man consulted for the treatment of a missing right first mandibular molar by implant placement. The cone-beam computed tomography (CBCT) data were imported into medical image processing software for analysis, and the implant design was simulated. The implant design on CBCT was transferred to the mandibular model using TPT, and the implant surgical guide was made to guide the dental implant operation. CBCT was performed postoperatively and compared with the preoperative design to check the accuracy. The central deviation of the implant head was 0.31 mm, the central deviation of the implant apex was 0.93 mm, and the implant angular deviation was 2.45°. Conclusion The use of tetrahedral positioning technology based on CBCT data is a new method for making implant guides. It is a promising technique offering a highly predictable outcome and lower risk of iatrogenic damage. However, these results should be interpreted with care since they are based on limited evidence from a case report. Larger population studies with longer follow-up periods and standardized experimental studies are required.

2012 ◽  
Vol 38 (5) ◽  
pp. 639-641 ◽  
Author(s):  
Aditi Nanda ◽  
Veen Jain

The accurate positioning of implant in bone is important in order to meet the biological, esthetic, and biomechanical requirements of the prosthesis. This becomes crucial in flapless implant placement. The combination of bone sounding and use of a surgical guide will allow precise placement of a dental implant, abutment, and provisional restoration in a minimally invasive manner. A technique to transfer the diagnostic information to the surgical guide is described in this report. The chief advantage of the procedure is the ability to apply flapless implant placement surgery and immediate loading.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Dong Wu ◽  
Lin Zhou ◽  
Jin Yang ◽  
Bao Zhang ◽  
Yanjun Lin ◽  
...  

Abstract Objectives To compare the accuracy of dynamic navigation (DN) with a static surgical guide (SSG) for dental implant placement and the influence factors such as the experience of the surgeon and the implant sites. Methods and materials A total of 38 implants, which underwent the dynamic navigation, and 57 implants which underwent a static surgical guide were enrolled in the retrospective study. Coronal deviation, apical deviation, and angular deviation were compared between the DN and SSG groups, along with the different experience level of surgeons and implant sites in the DN group. Results There were no statistically significant differences between the DN and SSG groups, and the experience level of the surgeons and implant sites in the DN group. However, the apical deviation of the DN was slightly higher than the SSG group in the anterior teeth (P = 0.028), and the angular deviation of DN was smaller than the SSG group in the molar. Conclusion Dynamic navigation can achieve accurate implant placement as well as the static surgical guide. Additionally, the experience level of the surgeon and implant site do not influence the accuracy of dynamic navigation, while the accuracy of DN seems higher than the SSG in molar.


2015 ◽  
Vol 2015 ◽  
pp. 1-7
Author(s):  
Doğu Ömür Dede ◽  
M. Cenk Durmuşlar ◽  
Onur Şahın ◽  
Ayşegül Köroğlu ◽  
Özer İşısağ

This case report presents a patient who had been rehabilitated with a telescopic overdenture and implant supported fixed partial denture (ISFPD). The treatment process was as follows: (1) fabricating telescopic crowns and overdenture prosthesis for the lower jaw and a temporary complete denture for the upper jaw, (2) using the temporary denture as diagnostic and surgical guide to optimize dental implant placement, and (3) fabricating ISFPD for the upper jaw. Using the patient’s existing or temporary denture not only serves as an alternative surgical guide to calibrate the dental implant locations but also helps to finish the restoration at desired dimension, size, and anatomic form.


Author(s):  
Giovanni de Almeida Prado Di Giacomo ◽  
Patrícia Cury ◽  
Airton Moreira da Silva ◽  
Jorge Vicente Lopes da Silva ◽  
Carlos Eduardo Pompeo Souto ◽  
...  

This study was designed to evaluate the accuracy of a novel computer-designed and selectively laser sintered surgical guide for flapless dental implant placement in the edentulous jaw. Fifty dental implants were placed in 11 patients with at least one totally edentulous jaw. Initially, cone-beam computed tomography (CBCT) was performed in each patient to define the virtual position of the dental implants based on the assessment of bone availability and the proposed dental prosthesis. After virtual planning, 3D surgical guides were printed using selective laser sintering. CBCT was repeated after the surgery, and the pre-and postoperative images were overlapped in the CAD software to compare the planned and actual positions of the dental implants using a one-sample t-test. The mean ± angular standard deviation between the long axes of the planned and final dental implant positions was 4.58 ±2.85 degrees; The linear deviation in the coronal position was  0.87 ± 0.49 mm and  in the apical region of the dental implants was 1.37 ± 0.69 mm. These differences were statistically significant (p <0.001). The proposed modifications reduced the deviations, resulting in an improvement in the technique. We were able to place implants and temporary prostheses using the present protocol, taking into account the differences between the planned and final positions of the dental implants.


2021 ◽  
pp. 29-30
Author(s):  
Deepika Sharma ◽  
Tarun Gaur ◽  
Karunakaran Keshav

With the advancement in the dental implant treatment, many new innovative improvements have been developed in the designs and components of implants. These improvements helps to handle the compromising situations where sometimes the good treatment option can become more challenging. One of the such grueling condition is implant placement in the anterior maxilla where dentist has to fulll both aesthetic and functional demand. Many aesthetic failures of implant have been reported in the literature in the anterior maxilla. One of them is placing implant in sites with deciency of facial bone thickness which sometimes resulted in malposition of implant. This case report discusses about the prosthodontic correction of malpositioned implant in the anterior maxilla by using castable abutment. The use of castable abutment is concluded as successful treatment option for complex misaligned and malposed single dental implant.


2019 ◽  
Vol 2019 ◽  
pp. 1-4 ◽  
Author(s):  
Antonio Scarano ◽  
Bartolomeo Assenza ◽  
Francesco Inchingolo ◽  
Filiberto Mastrangelo ◽  
Felice Lorusso

Background. The immediate placement of a dental implant could represent an option treatment for the rehabilitation of a postextractive missing tooth socket to replace compromised or untreatable teeth, with the advantage of single-session surgery. In this way, the anatomy of the alveolar bone defect, the preservation of the buccal cortical bone, and the primary stability of the fixture represent the critical factors that consent a precise implant placement. Objective. This case report describes a novel fixture design for postextractive alveolar socket immediate implant. Methods. Two patients (25 and 31 years old) were treated for postextractive dental implant placement to replace both central upper incisor teeth with four implants. The residual bone implant gap was not filled with graft or bone substitute. The restoration was provided following a standard loading protocol by a cement-sealed prosthetic abutment. Results. Clinically, all implants positioned showed an excellent insertion torque. No postoperative complications were reported. At 6 months of healing, the buccal cortical bone and the implant stability were present and well maintained. Conclusion. The evidence of this study allows us to underline the possible advantages of this new fixture design for postextractive implant technique.


2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Bruno Freitas Mello ◽  
Márcio de Carvalho Formiga ◽  
Luiz Fernando de Souza da Silva ◽  
Gustavo dos Santos Coura ◽  
Jamil Awad Shibli

The guided bone regeneration (GBR) technique has been used to achieve optimal bone volume augmentation and allow dental implant placement in atrophic maxilla and mandible, with predictable results and high survival rates. The use of bone substitutes has reduced the necessity of autogenous bone grafts, reducing the morbidity at the donor areas and thus improving the patients’ satisfaction and comfort. This clinical case report shows a clinical and histological evaluation of the bone tissue behavior, in a case that required the horizontal augmentation of the alveolar ridge, with the use of xenograft biomaterial and further dental implant placement. After six months of healing time, six implants were placed, and a bone biopsy was done. The histological analysis depicted some fragments of the xenograft bone graft, integrated with the new-formed bone tissue.


2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Algirdas Puisys ◽  
Viktorija Auzbikaviciute ◽  
Renata Simkunaite-Rizgeliene ◽  
Dainius Razukevicius ◽  
Rokas Linkevicius ◽  
...  

The aim of this case report is to show that bone remineralization around dental implants with a history of peri-implantitis is possible after irritant factors are removed and only conservative treatment is performed. Patient came to the clinic after three years of dental implant placement complaining about swelling, sensitivity and gingiva color changes at the posterior part of the maxilla. During radiographic and intraoral examinations peri-implantitis of the #24 implant site was diagnosed. The surgical treatment method was rejected and performed conservative treatment instead. The outcome is promising; periapical radiographs three months later showed bone remineralization as well as stable bone after 10 years. A key clinical message: Bone remineralization around dental implants with a history of peri-implantitis is possible after irritant factors are removed and conservative treatment performed.


Sign in / Sign up