scholarly journals External fixation versus elastic stable intramedullary nailing in the treatment of open tibial shaft fractures in children

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Pan Hong ◽  
Saroj Rai ◽  
Xin Tang ◽  
Ruikang Liu ◽  
Jin Li

Abstract Introduction External fixator (EF) is a popular choice for open tibial fractures, but pin tract infection (PTI) and refracture are common complications. Elastic stable intramedullary nail (ESIN) has been reported in the treatment for open tibial fractures. This study aims to compare the clinical outcomes of EF vs. ESIN in the treatment for open tibial shaft fracture in children retrospectively. Methods Patients aged 5–11 years with Gustilo-Anderson II and IIIA tibial shaft fracture treated at our institute from January 2008 to January 2018 were reviewed retrospectively and categorized into EF and ESIN groups. Patients with pathological fracture, neuromuscular disorder, metabolic disease, previous tibial fracture or instrumentation, and polytrauma were excluded. Patients with follow-up < 24 months or incomplete medical records were also excluded. Results In all, 55 patients (33 males, 22 females) were included in the EF group, whereas 37 patients (21 males, 16 females) were included in the ESIN group. There was no statistically significant difference between the two groups concerning sex, age, body weight, duration from injury to surgery, Gustilo-Anderson (GA) classification, and concomitant injuries. There was no case of nonunion and malunion in either group. The angulation at the latest follow-up was higher in the EF group than the ESIN group (P < 0.01). The radiological union was faster in the ESIN group (7.0 ± 0.9 weeks) than those in the EF group (9.0 ± 2.2 weeks) (P < 0.01). Limb length discrepancy (LLD) was more in the EF group (12.1 ± 4.4, mm) than in the ESIN group (7.3 ± 4.3, mm) (P < 0.01). Conclusion ESIN is a viable option in selected patients of GA grade II and IIIA open tibial fractures with comparable clinical outcomes as external fixator. Pin tract infection is the most troublesome complication in the EF group while implant prominence is a nuisance in the ESIN group.

2021 ◽  
Author(s):  
Pan Hong ◽  
Saroj Rai ◽  
Xin Tang ◽  
Ruikang Liu ◽  
Jin Li

Abstract IntroductionExternal fixator (EF) is a preferred choice for open tibial fractures, but pin tract infection (PTI) and refracture are common complications. Elastic stable intramedullary nail (ESIN) has been reported in the treatment for open tibial fractures. This study aims to compare the clinical outcomes of EF vs. ESIN in the treatment for open tibial shaft fracture in children retrospectively.Material and methodsPatients aged 5-11 years old with Gustilo-Anderson II and IIIA tibial shaft fracture treated at our institute from January 2008 to January 2018 were reviewed retrospectively and categorized into EF (n = 55) and ESIN (n = 37) group. Patients with pathological fracture, neuromuscular disorder, metabolic disease, previous tibial fracture or instrumentation, and polytrauma were excluded. Patients with follow up less than 24 months or incomplete medical records were also excluded. ResultsIn all, fifty-five patients (33 males, 22 females) were included in the EF group, whereas 37 patients (21 males, 16 females) were included in the ESIN group. There was no significant difference between the two groups concerning sex, age, body weight, duration from injury to surgery, Gustilo-Anderson (GA) classification, and concomitant injuries. There was no patient of nonunion and malunion in either group. The incidence of implant prominence was higher in the ESIN group (16%) than those in the EF group (0), P < 0.001. The angulation was higher in the EF group than ESIN group in coronal and sagittal plane, P < 0.001. The radiological union was faster in the ESIN group (7.0 ± 0.9, weeks) than those in the EF group (9.0 ± 2.2), P < 0.001. Limb length discrepancy (LLD) was significantly longer in the EF group (12.1 ± 4.4, mm) than those in the ESIN group (7.3 ± 4.3, mm), P < 0.001. ConclusionESIN is a viable option in selected patients of GA grade II and IIIA open tibial fractures with comparable clinical outcomes as external fixator, but with less complications including superficial infection, residual angulation and refracture after hardware removal.


BMC Surgery ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yanshi Liu ◽  
Jialin Liu ◽  
Maimaiaili Yushan ◽  
Zhenhui Liu ◽  
Tao Zhang ◽  
...  

Abstract Background The hexapod external fixator (HEF) is increasingly used for high-energy tibial shaft fracture care as more general orthopedic surgeons are gaining expertise of this versatile device. The purpose of this study was to evaluate the clinical effectiveness of the HEF for definitive management in patients with high-energy tibial shaft fractures. Methods The study was conducted on 34 patients with tibial shaft fractures who were admitted or referred to our institution and consented to HEF treatment from Jan 2016 to June 2019, including 27 males and 7 females with a mean age of 39 years (range 18 to 65 years). Patients' clinical and radiological data, and the final clinical outcomes at a minimum of 12 months follow-up were collected and retrospectively analyzed. All complications were documented according to Paley’s classification. The clinical outcomes were evaluated using the Association for the Study and Application of the Method of Ilizarov criteria (ASAMI) at the last clinical visit. Results All patients remained in the HEF for a mean of 26 weeks (range 15 to 52 weeks) and acquired complete bone union. The satisfactory alignment was achieved in all patients, and all the patients were able to perform daily activities with no difficulty at the last clinical visit. Complications included pin tract infection (44%), delayed union (6%), nonunion (3%), and joint stiffness (3%). The ASAMI bony result was excellent in 31 patients and good in 3. The ASAMI functional result was excellent in 27 patients, good in 6, and fair in 1. Conclusions Definitive management using the hexapod external fixator is an alternative and effective method for high-energy tibial shaft fractures, including technical advantages of early trauma-control, the versatility of achieving excellent alignment, and the continuity of device until bone union.


1999 ◽  
Vol 12 (3) ◽  
pp. 557
Author(s):  
Jeung Tak Suh ◽  
Byung Guk Park ◽  
Chong Il Yoo

2019 ◽  
Vol 27 (1) ◽  
pp. 89-92
Author(s):  
Malinda Rasith Ileperuma ◽  
Badra Hewavithana

A case of post-traumatic proximal peroneal artery pseudoaneurysm following a proximal tibial shaft fracture, complicated by acute compartment syndrome, fixed using an external fixator, in a 22-year-old female is presented. She was investigated for sudden-onset bleeding from the external fixator pin site, 6 weeks after the initial injury, was anaemic and diagnosed with a pseudoaneurysm at lower limb angiography. Contrast leak from the site of pseudoaneurysm was noted and open surgery with ligation of the pseudoaneurysm was performed. This rare complication of a proximal tibial shaft fracture has to be considered in patients presenting with acute bleeding from the surgical site or from pin sites after a significant lag period and requires a high index of suspicion.


1999 ◽  
Vol 12 (2) ◽  
pp. 272
Author(s):  
Dong Bae Shin ◽  
Joon Cheol Choi ◽  
Young Soo Lee ◽  
Yong Jeng Kim ◽  
Soo Hong Han ◽  
...  

BMJ Open ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. e035404
Author(s):  
Thibaut Galvain ◽  
Abhishek Chitnis ◽  
Konstantina Paparouni ◽  
Cindy Tong ◽  
Chantal E Holy ◽  
...  

ObjectivesDetermine the impact of infections on direct costs and healthcare resource use in England for patients undergoing intramedullary nailing (IMN) for tibial shaft fractures.DesignNon-concurrent cohort based on retrospectively collected data with 2-year follow-up.SettingEngland.ParticipantsThe study population included adult patients (≥18 years) in England with a diagnosis of tibial shaft fracture (International Classification of Diseases-10, S822) in the inpatient setting between May 2003 and June 2017 followed by a procedure for IMN for tibial shaft fracture within 30 days. Patient data were derived from the Clinical Practice Research Datalink linked to National Health Service Hospital Episode Statistics datasets.Primary independent variableInfection.Primary and secondary outcome measuresThe primary outcome was total inpatient costs from index stay admission through 1 year of follow-up. Secondary outcome included cumulative total healthcare costs, and resource utilisation at 30 days, 90 days, 1 year and 2 years.ResultsOverall, 805 patients met the inclusion criteria. At index inpatient stay, 3.7% had a post-IMN infection, rising to 11.7% at 1 year. One-year inpatient costs were 80% higher for patients with infection (p<0.001). Total costs were estimated to be £14 756 (95% CI £13 123 to £16 593) for patients with infection versus £8279 (95% CI £7946 to £8626). Length of stay (LOS), readmission and reoperation were the key drivers of healthcare costs (all p<0.001). After adjustment, LOS was higher by 109% (95% CI 62% to 169%), from 10.5 days to 21.9 days, for patients with infection. The odds of being readmitted or requiring reoperation were higher by 5.18 times (95% CI 3.01 to 9.13) and 2.47 times (95% CI 1.48 to 4.09), respectively, for patients with infection versus those without infection.ConclusionsPost-IMN infection significantly increases inpatient costs, LOS, readmissions and reoperations associated with tibial fracture fixation. Healthcare burden could be reduced through novel surgical site infection prevention strategies.


Sign in / Sign up

Export Citation Format

Share Document