scholarly journals Diagnostic value of prehospital arterial blood gas measurements – a randomised controlled trial

Author(s):  
Stine T. Zwisler ◽  
Yecatarina Zincuk ◽  
Caroline B. Bering ◽  
Aleksander Zincuk ◽  
Mads Nybo ◽  
...  
Author(s):  
Tom Scott ◽  
Hanna van Waart ◽  
Xavier CE Vrijdag ◽  
David Mullins ◽  
Peter Mesley ◽  
...  

Arterial blood gas (ABG) measurements at both maximum depth and at re-surfacing prior to breathing have not previously been measured during freedives conducted to extreme depth in cold open-water conditions. An elite freediver was instrumented with a left radial arterial cannula connected to two sampling syringes through a low-volume splitting device. He performed two open-water dives to 60 metres depth (197', 7 atmospheres absolute pressure) in the constant weight with fins competition format. ABG samples were drawn at 60 metres (by a mixed-gas scuba diver), and again on re-surfacing before breathing. An immersed surface static apnea, of identical length to the dives and with ABG sampling at identical times, was also performed. Both dives lasted approximately two minutes. PaO2 increased during descent from an indicative baseline of 15.8 kPa (after hyperventilation and glossopharyngeal insufflation) to 42.8 and 33.3 kPa (dives one and two), and decreased precipitously (to 8.2 and 8.6 kPa) during ascent. PaCO2 also increased from a low indicative baseline of 2.8 kPa to 6.3 and 5.1 kPa on dives one and two; an increase not explained by metabolic production of CO2 alone since PaCO2 actually decreased during ascent (to 5.2 and 4.5 kPa). Surface static apnea caused a steady decrease in PaO2 and increase in PaCO2 without the inflections provoked by depth changes. Lung compression and expansion provoke significant changes in both PaO2 and PaCO2 during rapid descent and ascent on a deep freedive. These changes generally support predictive hypotheses and previous findings in less extreme settings.


Resuscitation ◽  
2018 ◽  
Vol 130 ◽  
pp. e143
Author(s):  
Caroline Bach Bering ◽  
Yecatarina Zincuk ◽  
Stine Thorhauge Zwisler ◽  
Aleksander Zincuk ◽  
Søren Mikkelsen

Arterial blood gas (ABGs) analysis forms the cornerstone of emergency respiratory investigation. In many situations values obtained dictate management strategy and facilitate decision-making. It is an uncomfortable procedure for the patients and if repeated ABGs are required, consider whether less invasive measures, such as respiratory rate, pulse oximetry or capillary blood gas measurements could be used....


1988 ◽  
Vol 63 (7 Spec No) ◽  
pp. 743-747 ◽  
Author(s):  
B I McLain ◽  
J Evans ◽  
P R Dear

2021 ◽  
Author(s):  
Luke A. White ◽  
Benjamin S. Maxey ◽  
Giovanni F. Solitro ◽  
Hidehiro Takei ◽  
Steven A. Conrad ◽  
...  

Abstract Background: The COVID-19 pandemic revealed a substantial and unmet need for low-cost, easily accessible mechanical ventilation strategies for use in medical resource-challenged areas. Internationally, several groups developed non-conventional COVID-19 era emergency ventilator strategies as a stopgap measure when conventional ventilators were unavailable. Here, we compared our FALCON emergency ventilator in a rabbit model and compared its safety and functionality to conventional mechanical ventilation. Methods: New Zealand white rabbits (n = 5) received mechanical ventilation from either the FALCON or a conventional mechanical ventilator (Engström CarestationTM) for 1 hour each. Airflow and pressure, blood O2 saturation, end tidal CO2, and arterial blood gas measurements were measured. Additionally, gross and histological lung samples were compared to spontaneously breathing rabbits (n = 3) to assess signs of ventilator induced lung injury.Results: All rabbits were successfully ventilated with the FALCON. At identical ventilator settings, tidal volumes, pressures, and respiratory rates were similar between both ventilators, but the inspiratory to expiratory ratio was lower using the FALCON. End tidal CO2 was significantly higher on the FALCON, and arterial blood gas measurements demonstrated lower arterial partial pressure of O2 at 30 minutes and higher arterial partial pressure of CO2 at 30 and 60 minutes using the FALCON. However, when ventilated at higher respiratory rates, we observed a stepwise decrease in end tidal CO2. Poincaré plot analysis demonstrated small but significant increases in short-term and long-term variation of peak inspiratory pressure generation from the FALCON. Wet to dry lung weight and lung injury scoring between the mechanically ventilated and spontaneously breathing rabbits were similar. Conclusions: Although conventional ventilators are always preferable outside of emergency use, the FALCON ventilator safely and effectively ventilated healthy rabbits without lung injury. Emergency ventilation using accessible and inexpensive strategies like the FALCON may be useful for communities with low access to medical resources and as a backup form of emergency ventilation.


2020 ◽  
pp. 175114372097384
Author(s):  
Kay Mitchell ◽  
Karen E Salmon ◽  
David Egbosimba ◽  
Gavin Troughton ◽  
Mike PW Grocott

Introduction The ProximaTM point of care (POC) device enables arterial blood gas (ABG) samples to be analysed without the nurse leaving the patient. The benefits of this for work efficiency have not been evaluated. Methods We compared the time taken to obtain an ABG result using ProximaTM versus a standard ABG sampling system. Twenty patients were randomized to ABG sampling using ProximaTM, or a standard ABG system. Nurses were observed performing all ABG sampling episodes for a minimum of 24 hours and no more than 72 hours. Results The mean time taken to obtain a result using ProximaTM was 4:56 (SD = 1:40) minutes compared to 6:31 (SD = 1:53) minutes for the standard ABG technique (p < 0.001). Mean time away from the patient's bedside was 3.07 (SD = 1:17) minutes using the standard system and 0 minutes using ProximaTM (p < 0.001). Conclusions Reduced time for blood gas sampling and avoidance of time away from patients may have significant patient safety and resource management implications, but the clinical and financial significance were not evaluated.