scholarly journals Quality of focused thoracic ultrasound performed by emergency medical technicians and paramedics in a prehospital setting: a feasibility study

Author(s):  
Pia Iben Pietersen ◽  
Søren Mikkelsen ◽  
Annmarie T. Lassen ◽  
Simon Helmerik ◽  
Gitte Jørgensen ◽  
...  

Abstract Background In a prehospital setting, the severity of respiratory symptoms in patients calling for an ambulance differ. The initial evaluation, diagnosing, and thereby management can be challenging because respiratory symptoms can be caused by disease in many organs. Ultrasound examinations can contribute with important information and support the clinical decision-making. However, ultrasound is user-dependent and requires sufficient knowledge and training. The aim of this study was to explore the quality of thoracic ultrasound examinations performed on patients by emergency medical technicians and paramedics in a prehospital, clinical setting. Methods From November 2018 – April 2020, Danish emergency medical technicians and paramedics (n = 100) performed thoracic ultrasound examinations on patients with respiratory symptoms using a portable ultrasound device. The ultrasound examinations were stored and retrospectively assessed by a reviewer blinded to the patients’ symptoms and history, as well as the emergency medical technicians’ and paramedics’ findings. The image quality was scored from 1 to 5. The findings determined by the reviewer was then correlated with a questionnaire filled out by the emergency medical technicians and paramedics regarding ultrasonic findings and potential change in treatment or management of the patient. The agreement in percentage and as Cohen’s kappa was explored. Results A total of 590 ultrasound examinations were assessed, resulting in a median image quality score of 3 (IQ1 = 4, IQ3 = 3). The overall agreement in percentage between the emergency medical technicians and paramedics and reviewer was high (87.7% for a normal scan, 89.9% for interstitial syndrome, 97.3% for possible pneumothorax, and 96.3% for pleural effusion). Cohen’s kappa varied from 0.01 for possible pneumothorax to 0.69 for pleural effusion. Based on the questionnaires (n = 406), the ultrasound examination entailed a change in treatment or visitation in 48 cases (11.7%) which in this study population encompasses a number-needed-to-scan of 8.5. Conclusion Emergency medical technicians and paramedics perform focused thoracic ultrasound examinations with adequate image quality sufficient to determine if pathology is present or not. The emergency medical technicians’ and paramedics’ assessment correlates to some extent with an experienced reviewer and their findings are most reliable for the inclusion of a normal scan or inclusion of pleural effusion. Implementation could possibly impact the number of patients receiving correct prehospital treatment and optimal choice of receiving facility.

Herz ◽  
2022 ◽  
Author(s):  
Uzair Ansari ◽  
Sonja Janssen ◽  
Stefan Baumann ◽  
Martin Borggrefe ◽  
Stephan Waldeck ◽  
...  

Abstract Background We investigated the feasibility of evaluating coronary arteries with a contrast-enhanced (CE) self-navigated sparse isotropic 3D whole heart T1-weighted magnetic resonance imaging (MRI) study sequence. Methods A total of 22 consecutive patients underwent coronary angiography and/or cardiac computed tomography (CT) including cardiac MRI. The image quality was evaluated on a 3-point Likert scale. Inter-reader variability for image quality was analyzed with Cohen’s kappa for the main coronary segments (left circumflex [LCX], left anterior descending [LAD], right coronary artery [RCA]) and the left main trunk (LMT). Results Inter-reader agreement for image quality of the coronary tree ranged from substantial to perfect, with a Cohen’s kappa of 0.722 (RCAmid) to 1 (LCXprox). The LMT had the best image quality. Image quality of the proximal vessel segments differed significantly from the mid- and distal segments (RCAprox vs. RCAdist, p < 0.05). The LCX segments showed no significant difference in image quality along the vessel length (LCXprox vs. LCXdist, p = n.s.). The mean acquisition time for the study sequence was 553 s (±46 s). Conclusion Coronary imaging with a sparse 3D whole-heart sequence is feasible in a reasonable amount of time producing good-quality imaging. Image quality was poorer in distal coronary segments and along the entire course of the LCX.


1999 ◽  
Vol 14 (4) ◽  
pp. 32-35 ◽  
Author(s):  
J. Shelby Bowron ◽  
Knox H. Todd

AbstractIntroduction:Behavioral and social science research suggests that job satisfaction and job performance are positively correlated. It is important that Emergency Medical Services managers identify predictors of job satisfaction in order to maximize job performance among prehospital personnel.Purpose:Identify job stressors that predict the level of job satisfaction among prehospital personnel.Methods:The study was conducted with in a large, urban Emergency Medical Services (Emergency Medical Services) service performing approximately 60,000 Advanced Life Support (Advanced Life Support) responses annually. Using focus groups and informal interviews, potential predictors of global job satisfaction were identified. These factors included: interactions with hospital nurses and physicians; on-line communications; dispatching; training provided by the ambulance service; relationship with supervisors and; standing orders as presently employed by the ambulance service. These factors were incorporated into a 21 item questionnaire including one item measuring global job satisfaction, 14 items measuring potential predictors of satisfaction, and seven questions exploring demographic information such as age, gender, race, years of experience, and years with the company. The survey was administered to all paramedics and Emergency Medical Technicians (Emergency Medical Technicians s) Results of the survey were analyzed using univariate and multivariate techniques to identify predictors of global job satisfaction.Results:Ninety paramedics and Emergency Medical Technicians participated in the study, a response rate of 57.3%. Job satisfaction was cited as extremely satisfying by 11%, very satisfying by 29%, satisfying by 45%, and not satisfying by 15% of respondents. On univariate analysis, only the quality of training, quality of physician interaction, and career choice were associated with global job satisfaction. On multivariate analysis, only career choice (p = 0.005) and quality of physician interaction (p = 0.05) were predictive of global job satisfactionConclusion:Quality of career choice and interactions with physicians are predictive of global job satisfaction within this urban emergency medical service (Emergency Medical Technicians). Future studies should examine specific characteristics of the physician-paramedic interface that influence job satisfaction and attempt to generalize these results to other settings.


2016 ◽  
Vol 31 (10) ◽  
pp. 737-743
Author(s):  
Michael Åkesson ◽  
Leena Lehti ◽  
Peter Höglund ◽  
Per Åkeson ◽  
Johan Wassélius

Purpose This study was performed to compare the diagnostic quality of Gadofosveset-enhanced magnetic resonance venography with Gadobutrol-enhanced magnetic resonance venography and computed tomography venography for the deep veins of the lower extremities in patients with iliocaval venous pathology. Materials and methods Diagnostic capability and image quality were assessed by two independent readers. Inter-reader variability was analyzed by unweighted and quadratic weighted Cohen’s kappa values. Results The diagnostic capability was equal to or higher in the Gadofosveset group for all examined vessel segments compared with both control groups. The image quality score was significantly higher for the Gadofosveset group compared to both control groups. Inter-reader variability expressed by quadratic weighted Cohen’s kappa value (k) showed less variability in the Gadofosveset group compared to the control groups. Conclusion Our results show that Gadofosveset-enhanced magnetic resonance venography is a reliable technique in clinical routine practice, with image quality superior to both Gadobutrol-enhanced magnetic resonance venography and computed tomography venography.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Rebecca E. Cash ◽  
Robert A. Swor ◽  
Margaret Samuels-Kalow ◽  
David Eisenbrey ◽  
Anjali J. Kaimal ◽  
...  

Abstract Background Prehospital obstetric events encountered by emergency medical services (EMS) can be high-risk patient presentations for which suboptimal care can cause substantial morbidity and mortality. The frequency of prehospital obstetric events is unclear because existing descriptions have reported obstetric and gynecological conditions together, without delineating specific patient presentations. Our objective was to identify the types, frequency, and acuity of prehospital obstetric events treated by EMS personnel in the US. Methods We conducted a cross-sectional analysis of EMS patient care records in the 2018 National EMS Information System dataset (n=22,532,890). We focused on EMS activations (i.e., calls for service) for an emergency scene response for patients aged 12-50 years with evidence of an obstetric event. Type of obstetric event was determined by examining patient symptoms, the treating EMS provider’s impression (i.e., field diagnosis), and procedures performed. High patient acuity was ascertained by EMS documentation of patient status and application of the modified early obstetric warning system (MEOWS) criteria, with concordance assessed using Cohen’s kappa. Descriptive statistics were calculated to describe the primary symptoms, impressions, and frequency of each type of obstetric event among these activations. Results A total of 107,771 (0.6%) of EMS emergency activations were identified as involving an obstetric event. The most common presentation was early or threatened labor (15%). Abdominal complaints, including pain and other digestive/abdomen signs and symptoms, was the most common primary symptom (29%) and primary impression (18%). We identified 3,489 (3%) out-of-hospital deliveries, of which 1,504 were preterm. Overall, EMS providers documented 34% of patients as being high acuity, similar to the MEOWS criteria (35%); however, there were high rates of missing data for EMS documented acuity (19%), poor concordance between the two measures (Cohen’s kappa=0.12), and acuity differences for specific conditions (e.g., high acuity of non-cephalic presentations, 77% in EMS documentation versus 53% identified by MEOWS). Conclusion Prehospital obstetric events were infrequently encountered by EMS personnel, and about one-third were high acuity. Additional work to understand the epidemiology and clinical care of these patients by EMS would help to optimize prehospital care and outcomes.


2021 ◽  
Author(s):  
Zhilin Ji ◽  
Weiqiang Dou ◽  
Yaru Zhu ◽  
Yin Shi ◽  
Yuefen Zou

Abstract Objective: To investigate the feasibility of ultra-short echo time (UTE) MRI in assessing cartilage endplate (CEP) damage and evaluating the relationship between total endplate score (TEPS) and lumbar intervertebral disc (IVD) degeneration.Materials and methods: 35 patients were measured for IVD using UTE imaging at 3T MR. Subtracted UTE images between short and long TEs were obtained to depict anatomy of CEP. The SNR and CNR were calculated to assess the image quality. A new grading criterion for endplate evaluation was developed based on Rajasekarank.S grading in this study. Two radiologists were employed to evaluate CEP and bony vertebral endplates (VEP) using new grading criterion and assess TEPS, independently. Cohen's kappa analysis was applied to evaluate the inter-observer agreement of endplate damage assessment between two radiologists, and the Kendall's TAU-B analysis was employed to determine the relationship between TEPS and IVD degeneration evaluated with Pfirrmann grading.Results: Well structural CEP was depicted on subtracted UTE images and confirmed by high SNR (33.0±2.92) and CNR values (9.4±2.08). Qualified subtracted UTE images were used by two radiologists to evaluate CEP and VEP damage. Excellent inter-observer agreement was confirmed by high value in Cohen's kappa test (0.839,P<0.001). Ensured by this, 138 endplates from 69 IVDs of 35 patients were classified into six grades based on the new grading criterion and TEPS of each endplate was calculated. In addition, the degeneration degree of IVDs were classified into five grades. Finally, using Kendall's TAU-B analysis, significant relationship was obtained between endplate damage related TEPS and IVD degeneration (r= 0.864,P<0.001).Conclusion: Ensured by high image quality, UTE imaging might be considered an effective tool to assess CEP damage. Additionally, further calculated TEPS has shown strong positive association with IVD degeneration, suggesting that the severity of endplate damage is highly linked with the degree of IVD degeneration.


EXPLORE ◽  
2020 ◽  
Vol 16 (1) ◽  
pp. 61-68 ◽  
Author(s):  
Dallas M. Ducar ◽  
J. Kim Penberthy ◽  
John B. Schorling ◽  
Virginia A. Leavell ◽  
J. Forrest Calland

Author(s):  
Gaston Tabourel ◽  
Louis-Marie Terrier ◽  
Arnaud Dubory ◽  
Joseph Cristini ◽  
Louis-Romée Le Nail ◽  
...  

OBJECTIVE Survival scoring systems for spine metastasis (SPM) were designed to help surgical practice. The authors sought to validate the prognostic accuracy of the main preoperative scoring systems for SPM. METHODS It was hypothesized that true patient survival in SPM was better than that predicted using prognosis scores. To investigate this hypothesis, the authors designed a French national retrospective study of a prospectively collected multicenter database involving 739 patients treated for SPM between 2014 and 2017. RESULTS In this series, the median survival time for all patients from an SPM diagnosis was 17.03 ± 1.5 months. Sensitivity and specificity were estimated using the area under the curve (AUC). The AUC of Tomita’s prognosis score was the lowest and poorest (0.4 ± 0.023, range 0.35–0.44), whereas the AUC of the Tokuhashi score was the highest (0.825). The Lei score presented an AUC of 0.686 ± 0.022 (range 0.64–0.7), and the Rades score showed a weaker AUC (0.583 ± 0.020, range 0.54–0.63). Differences among AUCs were all statistically significant (p < 0.001). The modified Bauer score and the Rades score had the highest rate of agreement in predicting survival, with a weighted Cohen’s kappa of 0.54 and 0.41, respectively, indicating a moderate agreement. The revised Tokuhashi and Lei scores had a fair rate of agreement (weighted Cohen’s kappa = 0.24 and 0.22, respectively). The van der Linden and Tomita scores demonstrated the worst performance, with only a “slight” rate of agreement (weighted Cohen’s kappa = 0.19 and 0.16, respectively) between what was predicted and the actual survival. CONCLUSIONS The use of prognostic scoring systems in the estimation of survival in patients with SPM has become obsolete and therefore underestimates survival. Surgical treatment decisions should no longer be based on survival estimations alone but must also take into account patient symptoms, spinal instability, and quality of life.


Stroke ◽  
2017 ◽  
Vol 48 (suppl_1) ◽  
Author(s):  
Jelle Demeestere ◽  
Carlos Garcia-Esperon ◽  
Longting Lin ◽  
Allan Loudfoot ◽  
Andrew Bivard ◽  
...  

Objective: To assess if simplifying a prehospital 8-item NIHSS scale (NIHSS-8, fig 1) to a 0 (symptom absent) – 1 (symptom present) scoring system increases interrater agreement between emergency medical services (EMS) and stroke specialists. Methods: We analysed interrater agreement between EMS and stroke specialists of a single centre on a prospectively collected cohort of 64 suspected acute ischemic stroke patients. EMS performed NIHSS-8 score upon patient arrival at the emergency department. The stroke specialist scored the full 15-item NIHSS blind to the EMS scores and within 5 minutes of patient arrival. Linear-weighted Cohen’s kappa statistics was used to assess agreement between EMS and stroke specialist on the total NIHSS-8 score and each NIHSS-8 scale item. We then simplified each item to a 0-1 score and reassessed interrater agreement for the overall NIHSS-8 scale using linear-weighted Cohen’s kappa statistics and for each NIHSS-8 item using Cohen’s kappa statistics. We used Cohen’s kappa statistics to assess agreement for original and simplified NIHSS-8 cut-off scores. Results: EMS and stroke specialist reached substantial agreement on overall NIHSS-8 scoring (linear-weighted kappa 0.69). Optimum agreement was reached for right arm weakness (linear-weighted kappa 0.79; Table 1) and a cut-off score of 2 and 5 (Cohen’s kappa 0.78; Table 2). When the score was simplified to a 0-1, overall agreement between EMS and stroke specialists was substantial (linear-weighted kappa 0.65). Optimum agreement was seen for LOC questions (Cohen’s kappa 0.78; Table 1) and a cut-off score of 2 (Cohen’s kappa 0.77; Table 2). Conclusion: Simplifying an 8-item prehospital NIHSS stroke scale does not increase interrater agreement between emergency medical services and stroke specialists.


2016 ◽  
Vol 32 (7) ◽  
pp. 453-458 ◽  
Author(s):  
Michael Åkesson ◽  
Leena Lehti ◽  
Peter Höglund ◽  
Per Åkeson ◽  
Johan Wassélius

Background High-quality non-invasive imaging of the deep venous system in the thorax is challenging, but nevertheless required for diagnosis of vascular pathology as well as for patient selection and preoperative planning for endovascular procedures. Purpose To compare the diagnostic quality of Gadofosveset-enhanced thoracic magnetic resonance venography, seven consecutive patients with suspected or known disease affecting the central thoracic veins were compared to seven consecutive magnetic resonance venography using conventional gadolinium-based contrast agents. Materials and methods Diagnostic capability, defined as the ability to assess vessel patency and pathologic conditions, for the major thoracic deep venous segments was assessed by two-independent readers. Both reviewers rated the overall subjective image quality on a four-graded scale, and inter-rater variability was analyzed using unweighted and weighted Cohen's kappa values. Results Diagnostic capability was generally considerably higher in the Gadofosveset group for all examined vessel segments. The overall images quality rating was significantly higher for the Gadofosveset group with a mean rating of 2.9 and 2.7 for the two-independent readers, compared to 1.2 and 1.0 for the control croup. Inter-rater variability showed less variability for the Gadofosveset group with a quadratic-weighted Cohen's Kappa value of 0.58 compared to 0.36 for the control group. Conclusion Our results show that Gadofosveset-enhanced magnetic resonance venography of the central thoracic veins is a reliable technique in clinical routine practice that results in diagnostic images, superior to conventional gadolinium-based contrast medium.


Sign in / Sign up

Export Citation Format

Share Document