Artificial Skin: A Fifth Route to Organ Repair and Replacement

2021 ◽  
pp. 119-133
Author(s):  
I. V. Yannas ◽  
D. P. Orgill
Keyword(s):  
2020 ◽  
Vol 16 (6) ◽  
pp. 722-737
Author(s):  
Cigdem Yengin ◽  
Emrah Kilinc ◽  
Fatma Gulay Der ◽  
Mehmet Can Sezgin ◽  
Ilayda Alcin

Background: Reverse İontophoresis (RI) is one of the promising non-invasive technologies. It relies on the transition of low magnitude current through the skin and thus glucose measurement becomes possible as it is extracted from the surface during this porter current flow. Objective: This paper deals with the development and optimization of an RI determination method for glucose. CE dialysis membrane based artificial skin model was developed and the dependence of RI extraction on various experimental parameters was investigated. Method: Dependence of RI extraction performance on noble electrodes (platinum, silver, palladium, ruthenium, rhodium) was checked with CA, CV and DPV, in a wide pH and ionic strength range. Optimizations on inter-electrode distance, potential type and magnitude, extraction time, gel type, membrane MWCO, usage frequency, pretreatment, artificial body fluids were performed. Results: According to the optimized results, the inter-electrode distance was 7.0 mm and silver was the optimum noble metal. Optimum pH and ionic strength were achieved with 0.05M PBS at pH 7.4. Higher glucose yields were obtained with DPV, while CA and CV achieved almost the same levels. During CA, +0.5V achieved the highest glucose yield and higher potential even caused a decrease. Glucose levels could be monitored for 24 hours. CMC gel was the optimum collection media. Pretreated CE membrane with 12kD MWCO was the artificial skin model. Pretreatment affected the yields while its condition caused no significant difference. Except PBS solution (simulated as artificial plasma), among the various artificial simulated body fluids, intestinal juice formulation (AI) and urine formulation U2 were the optimum extraction media, respectively. Conclusion: In this study, various experimental parameters (pretereatment procedure, type and MWCO values of membranes, inter-electrode distance, electrode material, extraction medium solvents, ionic strength and pH, collection medium gel type, extraction potential type and magnitude, extraction time and etc) were optimized for the non-invasive RI determination of glucose in a CE dialysis membrane-based artificial skin model and various simulated artificial body fluids.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Xiao-Bing Fu

AbstractWound healing, tissue repair and regenerative medicine are in great demand, and great achievements in these fields have been made. The traditional strategy of tissue repair and regeneration has focused on the level of tissues and organs directly; however, the basic process of repair at the cell level is often neglected. Because the cell is the basic unit of organism structure and function; cell damage is caused first by ischemia or ischemia-reperfusion after severe trauma and injury. Then, damage to tissues and organs occurs with massive cell damage, apoptosis and even cell death. Thus, how to achieve the aim of perfect repair and regeneration? The basic process of tissue or organ repair and regeneration should involve repair of cells first, then tissues and organs. In this manuscript, it is my consideration about how to repair the cell first, then regenerate the tissues and organs.


Author(s):  
Lei Li ◽  
Long‐Xiang Cheng ◽  
Liu Yang ◽  
Jun‐Cheng Zhang
Keyword(s):  

JTCVS Open ◽  
2020 ◽  
Vol 3 ◽  
pp. 164-168
Author(s):  
Shaf Keshavjee
Keyword(s):  

Biomaterials ◽  
2001 ◽  
Vol 22 (20) ◽  
pp. 2777-2783 ◽  
Author(s):  
Sung Ran Hong ◽  
Seung Jun Lee ◽  
Jong Won Shim ◽  
Young Seon Choi ◽  
Young Moo Lee ◽  
...  

Author(s):  
Tsuyoshi Sekitani ◽  
Tomoyuki Yokota ◽  
Makoto Takamiya ◽  
Takayasu Sakurai ◽  
Takao Someya

Sign in / Sign up

Export Citation Format

Share Document