Biodynamic Response of the Human Body in Vehicular Frontal Impact

Author(s):  
Narayan Yoganandan ◽  
Frank Pintar
Keyword(s):  
2010 ◽  
Vol 34-35 ◽  
pp. 111-116 ◽  
Author(s):  
Li Bo Cao ◽  
Chong Zhen Cui ◽  
Ning Yu Zhu ◽  
Huan Chen

In this article, seven frontal impact simulation models with same restraint system and different human body models were established through the use of multi-body kinematics software MADYMO. The injuries in head, chest and femurs of different human models and the differences of these injuries were analyzed in detail. The weighted injury criterion was adopted to evaluate the overall injuries of different human body models. The results shows that the injury risk of smaller human body is much higher than the taller human body, and existing occupant restraint system that protects the 50th percentile American occupant well protects other size occupant poorly.


Author(s):  
Raed E. El-Jawahri ◽  
Jesse S. Ruan ◽  
Stephen W. Rouhana ◽  
Saeed D. Barbat ◽  
Priya Prasad

Ford Motor Company human body FE model was validated against 3-point & 4-point belted PMHS tests in frontal impact and PMHS knee impact. The chest deflection, chest acceleration, and belt force in frontal impact simulations were compared with the PMHS test data, while the impact force, femur acceleration, pelvis acceleration, and sacrum acceleration of the knee impact simulations were compared with the respective corridors from PMHS tests. The model used represents a 50th percentile adult male. It was used to study the effects of shoulder belt force limit on 3-point and 4-point restrained occupants in frontal impacts without airbags. A 25 g pulse and a shoulder belt load limit of 1, 2, 3, 4, 6, and 8 kN were used for the 3-point and 4-point restraint systems with a rigid steering wheel, front header, and windshield of a stiffer larger vehicle structure. The results showed that the head acceleration and the chest deflection of the 4-point belt system are less than the respective cases of the 3-point system while the chest acceleration levels were about the same in 3-point and 4-point belt. The mid-shaft femur forces were always higher in the 4-point belt than those of the 3-point belt.


2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Niclas Trube ◽  
Werner Riedel ◽  
Matthias Boljen

Abstract Background Active human body models (AHBM) consider musculoskeletal movement and joint stiffness via active muscle truss elements in the finite element (FE) codes in dynamic application. In the latest models, such as THUMS™ Version 5, nearly all human muscle groups are modeled in form of one-dimensional truss elements connecting each joint. While a lot of work has been done to improve the active and passive behavior of this 1D muscle system in the past, the volumetric muscle system of THUMS was modeled in a much more simplified way based on Post Mortem Human Subject (PMHS) test data. The stiffness changing effect of isometric contraction was hardly considered for the volumetric muscle system of whole human body models so far. While previous works considered this aspect for single muscles, the effect of a change in stiffness due to isometric contraction of volumetric muscles on the AHBM behavior and computation time is yet unknown. Methods In this study, a simplified frontal impact using the THUMS Version 5 AM50 occupant model was simulated. Key parameters to regulate muscle tissue stiffness of solid elements in THUMS were identified for the material model MAT_SIMPLIFIED_FOAM and different stiffness states were predefined for the buttock and thigh. Results During frontal crash, changes in muscle stiffness had an effect on the overall AHBM behavior including expected injury outcome. Changes in muscle stiffness for the thigh and pelvis, as well as for the entire human body model and for strain-rate-dependent stiffness definitions based on literature data had no significant effect on the computation time. Discussion Kinematics, peak impact force and stiffness changes were in general compliance with the literature data. However, different experimental setups had to be considered for comparison, as this topic has not been fully investigated experimentally in automotive applications in the past. Therefore, this study has limitations regarding validation of the frontal impact results. Conclusion Variations of default THUMS material model parameters allow an efficient change in stiffness of volumetric muscles for whole AHBM applications. The computation time is unaffected by altering muscle stiffness using the method suggested in this work. Due to a lack of validation data, the results of this work can only be validated with certain limitations. In future works, the default material models of THUMS could be replaced with recently published models to achieve a possibly more biofidelic muscle behavior, which would even allow a functional dependency of the 1D and 3D muscle systems. However, the effect on calculation time and model stability of these models is yet unknown and should be considered in future studies for efficient AHBM applications.


Author(s):  
Shulin Wen ◽  
Jingwei Feng ◽  
A. Krajewski ◽  
A. Ravaglioli

Hydroxyapatite bioceramics has attracted many material scientists as it is the main constituent of the bone and the teeth in human body. The synthesis of the bioceramics has been performed for years. Nowadays, the synthetic work is not only focused on the hydroapatite but also on the fluorapatite and chlorapatite bioceramics since later materials have also biological compatibility with human tissues; and they may also be very promising for clinic purpose. However, in comparison of the synthetic bioceramics with natural one on microstructure, a great differences were observed according to our previous results. We have investigated these differences further in this work since they are very important to appraise the synthetic bioceramics for their clinic application.The synthetic hydroxyapatite and chlorapatite were prepared according to A. Krajewski and A. Ravaglioli and their recent work. The briquettes from different hydroxyapatite or chlorapatite powders were fired in a laboratory furnace at the temperature of 900-1300°C. The samples of human enamel selected for the comparison with synthetic bioceramics were from Chinese adult teeth.


Author(s):  
Tong Wensheng ◽  
Lu Lianhuang ◽  
Zhang Zhijun

This is a combined study of two diffirent branches, photogrammetry and morphology of blood cells. The three dimensional quantitative analysis of erythrocytes using SEMP technique, electron computation technique and photogrammetry theory has made it possible to push the study of mophology of blood cells from LM, TEM, SEM to a higher stage, that of SEM P. A new path has been broken for deeply study of morphology of blood cells.In medical view, the abnormality of the quality and quantity of erythrocytes is one of the important changes of blood disease. It shows the abnormal blood—making function of the human body. Therefore, the study of the change of shape on erythrocytes is the indispensable and important basis of reference in the clinical diagnosis and research of blood disease.The erythrocytes of one normal person, three PNH Patients and one AA patient were used in this experiment. This research determines the following items: Height;Length of two axes (long and short), ratio; Crevice in depth and width of cell membrane; Circumference of erythrocytes; Isoline map of erythrocytes; Section map of erythrocytes.


1998 ◽  
Vol 23 (4) ◽  
pp. 382-387 ◽  
Author(s):  
James O. Ochanda ◽  
Eva A. C. Oduor ◽  
Rachel Galun ◽  
Mabel O. Imbuga ◽  
Kosta Y. Mumcuoglu

Sign in / Sign up

Export Citation Format

Share Document