Combined Thermal Engine-Heat Pump Systems for Low-Temperature Heat Generation

1976 ◽  
Vol 190 (1) ◽  
pp. 255-265 ◽  
Author(s):  
G. Angelino ◽  
P. Ferrari ◽  
G. Giglioli ◽  
E. Macchi

SYNOPSIS A system is described for low-temperature heat generation for space heating envisaging the adoption of an organic fluid external combustion engine as the direct drive for a heat pump. Waste heat from the engine condenser contributes a substantial fraction of the overall heat output. Progress in experimental work to ascertain the suitability of organic fluids to operate at comparatively high temperature without appreciable decomposition or corrosive action on materials is reported. Results are given of a computation program predicting the performance of systems of various capacity. For the examples considered yearly fuel consumption was calculated to range between 41 and 48% of that of a conventional plant.

Energies ◽  
2020 ◽  
Vol 13 (17) ◽  
pp. 4469
Author(s):  
Umara Khan ◽  
Ron Zevenhoven ◽  
Tor-Martin Tveit

Heat pumps are increasingly seen as efficient and cost-effective heating systems also in industrial applications. They can drastically reduce the carbon footprint of heating by utilizing waste heat and renewable electricity. Recent research on Stirling cycle-based very high temperature heat pumps is motivated by their promising role in addressing global environmental and energy-related challenges. Evaluating the environmental footprint of a heat pump is not easy, and the impacts of Stirling cycle-based heat pumps, with a relatively high temperature lift have received little attention. In this work, the environmental footprint of a Stirling cycle-based very high temperature heat pump is evaluated using a “cradle to grave” LCA approach. The results for 15 years of use (including manufacturing phase, operation phase, and decommissioning) of a 500-kW heat output rate system are compared with those of natural gas- and oil-fired boilers. It is found that, for the Stirling cycle-based HP, the global warming potential after of 15 years of use is nearly −5000 kg CO2 equivalent. The Stirling cycle-based HP offers an environmental impact reduction of at least 10% up to over 40% in the categories climate change, photochemical ozone formation, and ozone depletion when compared to gas- and oil-fired boilers, respectively.


Author(s):  
Lihua Dong ◽  
Hongyu Huang ◽  
Noriyuki Kobayashi

The present research of adsorption heat pump system for heating application mainly focuses on its miniaturization and high output. When the adsorption heat pump is downsized the heat energy is insufficient to meet heating application. In addition, a large amount of low-temperature heat energy in industry has not been utilized but discharged into the atmosphere as waste heat. To improve energy efficiency and reduce carbon dioxide emission, it is important to effectively utilize the low-temperature heat source which is usually discarded as waste heat. In order to solve the problem between the miniaturization and the high output, a miniature all-in-one type adsorption heat pump which can effectively utilize waste heat is designed. In this design, a heat exchanger coated with adsorption material is used as an adsorber or desorber, and another heat exchanger is used as an evaporator or condenser. A seal unit is formed by assembling two heat exchangers into a vacuum tight container and is connected to the surroundings only by hydraulic piping. Moreover, the adsorbent is a functional adsorbent material-zeolite (AQSOA FAM-Z02, Mitsubishi Plastics) which can be regenerated by utilizing the low-temperature heat energy between 75 and 100°C. In this paper the design and experimental performance of this all-in-one type adsorption heat pump are described.


Energies ◽  
2020 ◽  
Vol 13 (4) ◽  
pp. 954 ◽  
Author(s):  
Hanne Kauko ◽  
Daniel Rohde ◽  
Armin Hafner

District heating enables an economical use of energy sources that would otherwise be wasted to cover the heating demands of buildings in urban areas. For efficient utilization of local waste heat and renewable heat sources, low distribution temperatures are of crucial importance. This study evaluates a local heating network being planned for a new building area in Trondheim, Norway, with waste heat available from a nearby ice skating rink. Two alternative supply temperature levels have been evaluated with dynamic simulations: low temperature (40 °C), with direct utilization of waste heat and decentralized domestic hot water (DHW) production using heat pumps; and medium temperature (70 °C), applying a centralized heat pump to lift the temperature of the waste heat. The local network will be connected to the primary district heating network to cover the remaining heat demand. The simulation results show that with a medium temperature supply, the peak power demand is up to three times higher than with a low temperature supply. This results from the fact that the centralized heat pump lifts the temperature for the entire network, including space and DHW heating demands. With a low temperature supply, heat pumps are applied only for DHW production, which enables a low and even electricity demand. On the other hand, with a low temperature supply, the district heating demand is high in the wintertime, in particular if the waste heat temperature is low. The choice of a suitable supply temperature level for a local heating network is hence strongly dependent on the temperature of the available waste heat, but also on the costs and emissions related to the production of district heating and electricity in the different seasons.


Energies ◽  
2019 ◽  
Vol 12 (10) ◽  
pp. 1853 ◽  
Author(s):  
Pavel Neuberger ◽  
Radomír Adamovský

The efficiency of a heat pump energy system is significantly influenced by its low-temperature heat source. This paper presents the results of operational monitoring, analysis and comparison of heat transfer fluid temperatures, outputs and extracted energies at the most widely used low temperature heat sources within 218 days of a heating period. The monitoring involved horizontal ground heat exchangers (HGHEs) of linear and Slinky type, vertical ground heat exchangers (VGHEs) with single and double U-tube exchanger as well as the ambient air. The results of the verification indicated that it was not possible to specify clearly the most advantageous low-temperature heat source that meets the requirements of the efficiency of the heat pump operation. The highest average heat transfer fluid temperatures were achieved at linear HGHE (8.13 ± 4.50 °C) and double U-tube VGHE (8.13 ± 3.12 °C). The highest average specific heat output 59.97 ± 41.80 W/m2 and specific energy extracted from the ground mass 2723.40 ± 1785.58 kJ/m2·day were recorded at single U-tube VGHE. The lowest thermal resistance value of 0.07 K·m2/W, specifying the efficiency of the heat transfer process between the ground mass and the heat transfer fluid, was monitored at linear HGHE. The use of ambient air as a low-temperature heat pump source was considered to be the least advantageous in terms of its temperature parameters.


2020 ◽  
Vol 145 ◽  
pp. 02062
Author(s):  
Canzong Zhou ◽  
Shuyi Chen ◽  
Wei Cui ◽  
Zhengmao Yao

According to the research, thermoelectricity generation can recycle the heat contained in the cooling system of internal combustion engine. This paper is about taking advantage of the feature in the huge temperature difference at about 560 °C which is formed between high-temperature engine and LNG (Liquefied Natural Gas) in low temperature and the ability that LNG provides semiconductor with thermoelectric conversion material so as to produce the maximum output voltage in low temperature. We take advantage of lead telluride materials that adapt to the high temperature environment and bismuth telluride materials that adapt to the low temperature environment, both of which forms a circuit and are designed as a thermoelectric power generation device. Also, we confirm the possibility of applying the device to cars.


2020 ◽  
Vol 12 (19) ◽  
pp. 8178
Author(s):  
Fahid Riaz ◽  
Kah Hoe Tan ◽  
Muhammad Farooq ◽  
Muhammad Imran ◽  
Poh Seng Lee

Low-grade heat is abundantly available as solar thermal energy and as industrial waste heat. Non concentrating solar collectors can provide heat with temperatures 75–100 °C. In this paper, a new system is proposed and analyzed which enhances the electrical coefficient of performance (COP) of vapour compression cycle (VCC) by incorporating low-temperature heat-driven ejectors. This novel system, ejector enhanced vapour compression refrigeration cycle (EEVCRC), significantly increases the electrical COP of the system while utilizing abundantly available low-temperature solar or waste heat (below 100 °C). This system uses two ejectors in an innovative way such that the higher-pressure ejector is used at the downstream of the electrically driven compressor to help reduce the delivery pressure for the electrical compressor. The lower pressure ejector is used to reduce the quality of wet vapour at the entrance of the evaporator. This system has been modelled in Engineering Equation Solver (EES) and its performance is theoretically compared with conventional VCC, enhanced ejector refrigeration system (EERS), and ejection-compression system (ECS). The proposed EEVCRC gives better electrical COP as compared to all the three systems. The parametric study has been conducted and it is found that the COP of the proposed system increases exponentially at lower condensation temperature and higher evaporator temperature. At 50 °C condenser temperature, the electrical COP of EEVCRC is 50% higher than conventional VCC while at 35 °C, the electrical COP of EEVCRC is 90% higher than conventional VCC. For the higher temperature heat source, and hence the higher generator temperatures, the electrical COP of EEVCRC increases linearly while there is no increase in the electrical COP for ECS. The better global COP indicates that a small solar collector will be needed if this system is driven by solar thermal energy. It is found that by using the second ejector at the upstream of the electrical compressor, the electrical COP is increased by 49.2% as compared to a single ejector system.


2019 ◽  
Vol 142 (4) ◽  
Author(s):  
Md. Tareq Chowdhury ◽  
Esmail M. A. Mokheimer

Abstract Even though the renewable technologies are getting a gradually increasing share of the energy industry, the momentum of its growth is far away from outweighing the dominance of fossil fuel. Due to the concern for ozone depletion, global warming, and many more environmental hazards caused by fossil fuels, it is essential to substitute the conventional energy sources with renewables. Since this replacement cannot be done overnight, the conventional energy technologies should be integrated with renewables to minimize the pace of adverse effects on fossil fuel–based industries in the meantime. This way, the industries can be more efficient by utilizing waste heat, which accounts for 50% of the total energy generated now. This review paper outlines the role of solar energy in the generation of power and cooling systems that are capable of utilizing low-temperature heat sources below 400 °C. The review is primarily concentrated on line-focused concentrated solar power (CSP)-assisted solar technologies to be integrated with organic Rankine cycle (ORC) and absorption cooling systems. Photovoltaic and similar multigeneration systems are also discussed in brief.


Sign in / Sign up

Export Citation Format

Share Document