scholarly journals Determination of Total Hydroxyproline and Proline in Human Serum and Urine by HPLC with Fluorescence Detection.

1996 ◽  
Vol 19 (2) ◽  
pp. 163-166 ◽  
Author(s):  
Hirofumi INOUE ◽  
Yuuko DATE ◽  
Kazuya KOHASHI ◽  
Hironori YOSHITOMI ◽  
Yasuto TSURUTA
2021 ◽  
pp. 1-8
Author(s):  
Susan Sadeghi ◽  
Mohadeseh Hosseinpour-Zaryabi

A dispersive liquid-phase microextraction method combined with UV–vis spectrophotometry was utilized to highly selective determination of creatinine in human serum and urine samples. To overcome the interferences in complex matrices, creatinine reacted with 1,4-naphthoquinone-2- potassium sulfonate reagent to produce a red coloured product that could be extracted into a small volume of 1-hexyl-3-methylimidazolium hexafluorophosphate ([HMIM]PF6) ionic liquid solvent. To increase the sensitivity of the assay, gluconic acid capped silver nanoparticles (Ag NPs) were used. On addition of Ag NPs to the red coloured extracted product, the solution turned to blue accompanied with a red shift in wavelength around 620 nm that could be detected by the naked eye. The effective variables on the determination of creatinine such as concentration of the reagent, amount of formic and hydrochloric acids, type and volume of the extractant, and concentration of Ag NPs were investigated. Under the optimal conditions, the calibration plot was bimodal with linear ranges from 0.1 to 1.5 µg mL−1 and 1.5 to 105 µg mL−1 creatinine with a limit of detection 0.1 µg mL−1. The relative standard deviation for five measurements at 35 µg mL−1 concentration level was 3.8%. The newly developed assay was used for the determination of creatinine in human serum and urine specimens with satisfactory results.


2012 ◽  
Vol 2012 ◽  
pp. 1-5
Author(s):  
Jiangman Liu ◽  
Huan Yang ◽  
Yun Zhang ◽  
Min Wu ◽  
Haixiang Zhao ◽  
...  

A sensitive chemiluminescence (CL) method, based on the inhibitory effect of roxithromycin (ROX) on the CL reaction between luminol and dissolved oxygen in a flow-injection system, was first proposed for the determination of ROX at picogram levels. The decrement of CL intensity was linearly proportional to the logarithm of ROX concentrations ranging from 0.1 to 100 pg mL-1, giving the limit of detection (LOD) of 0.03 pg mL-1 (3σ). At a flow rate of 2.0 mL min-1, a complete analytical procedure including sampling and washing could be performed within 0.5 min, with relative standard deviations (RSDs) of less than 5.0% (n=5). The proposed procedure was applied successfully to the determination of ROX in pharmaceutical, human serum, and urine with the recoveries ranging from 90.0 to 110.0%.


Sign in / Sign up

Export Citation Format

Share Document