scholarly journals False negative results in the Roche assay for HDL-cholesterol

Author(s):  
Andries J Bakker ◽  
Appie Zijlstra ◽  
Marten P Leemhuis

Measurement of HDL-cholesterol is important in the risk evaluation of cardiovascular disease. Recently, we encountered a 61-year-old man with a negative result for HDL-cholesterol using the Roche assay. Further analysis revealed that this patient had a monoclonal Ig type IgM κ, with an electrophoresis-based concentration of 55.8 g/L, which apparently caused the negative result for HDL-cholesterol. Analysis of serum samples from other patients with monoclonal or polyclonal hypergammaglobulinaemia revealed that false negative results in the Roche assay for HDL-cholesterol may occur incidentally. Since negative results are detected easily in the laboratory, such patients do not pose a problem in daily practice. However, it is reasonable to suppose that false low results could also be caused by monoclonal as well as polyclonal Igs. Since such false low results remain undetected, vascular risk estimates consequently are altered and unnecessary treatment might be started.

1990 ◽  
Vol 36 (9) ◽  
pp. 1686-1688 ◽  
Author(s):  
H Christensen ◽  
H H Thyssen ◽  
O Schebye ◽  
A Berget

Abstract We examined three enzyme-linked immunosorbent assay (ELISA) kits for human choriogonadotropin (hCG) (pregnancy tests) for use with urine and serum samples: the Tandem Icon II hCG Urine and Tandem Icon II hCG Serum, the NovoClone Target hCG Test, and the Abbott TestPacks hCG-urine and hCG-serum. Paired comparison of the results from each kit indicated that the NovoClone Target assay showed significantly lower diagnostic sensitivity (P less than 0.05) than did the Tandem Icon II or Abbott TestPack, both for urine and for serum samples. None of the products demonstrated any significant difference (P greater than 0.05) in diagnostic specificity, but the NovoClone Target kit showed several serious false-negative results with both urine and serum. Paired testing of urine kits vs serum kits also showed no significant differences (P greater than 0.05) in diagnostic sensitivity or specificity. We found the Abbott kits to be the most convenient to use and to read.


Author(s):  
Xiumei Hu ◽  
Taixue An ◽  
Bo Situ ◽  
Yuhai Hu ◽  
Zihao Ou ◽  
...  

AbstractThe detection of serum antibodies to the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is emerging as a new tool for the coronavirus disease-2019 (COVID-19) diagnosis. Since many coronaviruses are sensitive to heat, heating inactivation of samples at 56 °C prior to testing is considered a possible method to reduce the risk of transmission, but the effect of heating on the measurement of SARS-CoV-2 antibodies is still unclear. By comparing the levels of SARS-CoV-2 antibodies before and after heat inactivation of serum at 56 °C for 30 minutes using a quantitative fluorescence immunochromatographic assay, we shown that heat inactivation significantly interferes with the levels of antibodies to SARS-CoV-2. The IgM levels of all the 34 serum samples (100%) from COVID-19 patients decreased by an average level of 53.56%. The IgG levels were decreased in 22 of 34 samples (64.71%) by an average level of 49.54%. Similar changes can also be observed in the non-COVID-19 diseases group (n=9). Of note, 44.12% of the detected IgM levels were dropped below the cut-off value after heating, suggesting heat inactivation can lead to false-negative results of these samples. Our results indicate that heat inactivation of serum at 56 °C for 30 minutes interferes with the immunoanalysis of antibodies to SARS-CoV-2. Heat inactivation prior to immunoanalysis is not recommended and the possibility of false-negative results should be considered if the sample was pre-inactivated by heating.


Parasitology ◽  
2020 ◽  
pp. 1-6
Author(s):  
Praphathip Eamsobhana ◽  
Anchalee Tungtrongchitr ◽  
Hoi-Sen Yong ◽  
Anchana Prasartvit ◽  
Darawan Wanachiwanawin ◽  
...  

Abstract Serological tests may yield false-negative results for specific antibodies detection before or at the early seroconversion phase. Tests that detect circulating antigens of Angiostrongylus cantonensis would therefore be of value in diagnosis to distinguish current or past infection. Here, a quick, easy to perform, portable and inexpensive diagnostic device for detection of 31-kDa A. cantonensis specific antigens had been developed. This sandwich dot-immunogold filtration assay (AcDIGFAAg), for detecting active angiostrongyliasis was produced using anti-A. cantonensis polyclonal antibody dotted on the nitrocellulose membrane as a capture agent and colloidal gold-labelled anti-31 kDa A. cantonensis antibody as a detection agent. A well-defined pink dot, indicating positivity, was seen readily by naked eye within 10–15 min. The AcDIGFAAg detected A. cantonensis-specific antigens in cerebrospinal fluid samples from 4 out of 10 serologically confirmed angiostrongyliasis cases and 2 out of 5 suspected cases with negative anti-A. cantonensis antibodies. Among the 19 patient sera with A. cantonensis infection, 2 showed positive reaction by AcDIGFAAg. No positive AcDIGFAAg reaction was observed in all the serum samples with other parasitic diseases, and the healthy controls. The present ‘AcDIGFAAg’ enables rapid qualitative detection of the specific 31-kDa antigens of A. cantonensis in clinical samples with potential for application even under resource-limited settings.


2001 ◽  
Vol 13 (4) ◽  
pp. 301-307 ◽  
Author(s):  
R. Varea ◽  
E. Monleón ◽  
C. Pacheco ◽  
L. Luján ◽  
R. Bolea ◽  
...  

The aim of this work was to investigate whether an enzyme-linked immunosorbent assay (ELISA) was useful for early detection of maedi-visna virus (MVV) infection in sheep under field conditions. An ELISA based on p25 recombinant protein and a gp46 synthetic peptide was used. Sequentially obtained serum samples ( n = 1,941) were studied for 4 years. ELISA results were compared with those of the agar gel immunodiffusion (AGID) test, and results of both tests were compared with a reference result established using consensus scores for at least 2 of 3 serologic techniques (AGID, ELISA, and western blotting, which was used to resolve result discrepancies between the other 2 techniques). A total of 247 discrepancies were observed between ELISA and AGID. Of these, 131 were due to an earlier detection of 120 sera by the ELISA and 11 sera by AGID. The remaining discrepancies (116) were due to the presence of false reactions in both tests. Fewer false-negative results were found by ELISA than with AGID (6 vs. 69 sera, respectively), whereas the number of false-positive results was virtually the same for ELISA and AGID (21 vs. 20, respectively). In relation to the reference result, ELISA sensitivity and specificity were 97.8% and 98.2%, respectively, whereas values for AGID were 76.3% and 98.3%, respectively. The agreement between ELISA and the reference result was higher than that between AGID and the reference result (κ value: 0.96 and 0.77, respectively). A variation in the ELISA signal (based on optical density) was observed during the study period, suggesting different antibody levels throughout the animal's life. The ELISA was useful for detecting MVV-infected sheep in field conditions and has potential for use in control and eradication programs.


2010 ◽  
Vol 56 (12) ◽  
pp. 1839-1844 ◽  
Author(s):  
David G Grenache ◽  
Dina N Greene ◽  
Anand S Dighe ◽  
Corinne R Fantz ◽  
Daniel Hoefner ◽  
...  

BACKGROUND Earlier studies have shown that increased concentrations of certain human chorionic gonadotropin (hCG) variants can cause false-negative results in some qualitative hCG devices. The objective of this study was to determine if increased concentrations of hCGβ and hCGβ core fragment (hCGβcf) cause falsely decreased results on 9 commercially available quantitative hCG assays. METHODS Several concentrations of purified hCGβ and hCGβcf were added to 2 sets of 6 serum samples with and without a fixed concentration of intact hCG. We examined 9 widely used immunoassays to measure immunoreactive hCG. Falsely decreased results were defined as those in which the measured hCG concentration was ≤50% of expected. RESULTS High concentrations of hCGβ (≥240 000 pmol/L) produced falsely decreased hCG measurements in 2 assays known to detect this variant. Similarly, high concentrations of hCGβcf (≥63 000 pmol/L) produced falsely decreased hCG measurements in 3 assays that do not detect purified hCGβcf. Two assays were identified that detected both hCGβ and hCGβcf, and neither produced falsely decreased results in the presence of high concentrations of these variants. CONCLUSIONS Extremely high concentrations of hCG variants can cause falsely decreased results in certain quantitative hCG assays. Of the 9 assays examined, none exhibited falsely decreased results in the presence of hCGβ concentrations typically associated with hCGβ-producing malignancies. Two assays exhibited decreased (>50%) hCG results in the presence of hCGβcf concentrations found during normal pregnancy.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


2020 ◽  
Vol 13 (1) ◽  
pp. 413-414 ◽  
Author(s):  
Mohamed Farouk Allam

Due to the international spread of COVID-19, the difficulty of collecting nasopharyngeal swab specimen from all suspected patients, the costs of RT-PCR and CT, and the false negative results of RT-PCR assay in 41% of COVID-19 patients, a scoring system is needed to classify the suspected patients in order to determine the need for follow-up, home isolation, quarantine or the conduction of further investigations. A scoring system is proposed as a diagnostic tool for suspected patients. It includes Epidemiological Evidence of Exposure, Clinical Symptoms and Signs, and Investigations (if available). This scoring system is simple, could be calculated in a few minutes, and incorporates the main possible data/findings of any patient.


2020 ◽  
Vol 18 ◽  
Author(s):  
Pegah Shakib ◽  
Mohammad Reza Zolfaghari

Background: Conventional laboratory culture-based methods for diagnosis of Streptococcus pneumoniae are time-consuming and yield false negative results. Molecular methods including real-time (RT)-PCR rapid methods and conventional PCR due to higher sensitivity and accuracy have been replaced instead traditional culture assay. The aim of the current study was to evaluate lytA gene for detection of Streptococcus pneumoniae in the cerebrospinal fluid of human patients with meningitis using real-time PCR assay. Material and Methods: In this cross-sectional study, a total of 30 clinical specimens were collected from patients in a period from September to December 2018. In order to evaluate the presence of lytA gene, conventional and real-time PCR methods were used without culture. Results: From 30 sputum samples five (16.66%) isolates were identified as S. pneumoniae by lytA PCR and sequencing. Discussion: In this research, an accurate and rapid real-time PCR method was used, which is based on lytA gene for diagnosis of bacteria so that it can be diagnosed. Based on the sequencing results, the sensitivity for detection of lytA gene was 100% (5/5).