scholarly journals Accuracy and Repeatability of Limb Scans Obtained on the Semi-Automatic Measuring Station

2020 ◽  
Vol 14 (4) ◽  
pp. 220-228
Author(s):  
Radosław Wichniarek ◽  
Filip Górski ◽  
Wiesław Kuczko ◽  
Magdalena Żukowska
1978 ◽  
Vol 48 ◽  
pp. 515-521
Author(s):  
W. Nicholson

SummaryA routine has been developed for the processing of the 5820 plates of the survey. The plates are measured on the automatic measuring machine, GALAXY, and the measures are subsequently processed by computer, to edit and then refer them to the SAO catalogue. A start has been made on measuring the plates, but the final selection of stars to be made is still a matter for discussion.


Author(s):  
Adrian F. van Dellen

The morphologic pathologist may require information on the ultrastructure of a non-specific lesion seen under the light microscope before he can make a specific determination. Such lesions, when caused by infectious disease agents, may be sparsely distributed in any organ system. Tissue culture systems, too, may only have widely dispersed foci suitable for ultrastructural study. In these situations, when only a few, small foci in large tissue areas are useful for electron microscopy, it is advantageous to employ a methodology which rapidly selects a single tissue focus that is expected to yield beneficial ultrastructural data from amongst the surrounding tissue. This is in essence what "LIFTING" accomplishes. We have developed LIFTING to a high degree of accuracy and repeatability utilizing the Microlift (Fig 1), and have successfully applied it to tissue culture monolayers, histologic paraffin sections, and tissue blocks with large surface areas that had been initially fixed for either light or electron microscopy.


2020 ◽  
Vol 5 (3) ◽  
pp. 622-636
Author(s):  
John Heilmann ◽  
Alexander Tucci ◽  
Elena Plante ◽  
Jon F. Miller

Purpose The goal of this clinical focus article is to illustrate how speech-language pathologists can document the functional language of school-age children using language sample analysis (LSA). Advances in computer hardware and software are detailed making LSA more accessible for clinical use. Method This clinical focus article illustrates how documenting school-age student's communicative functioning is central to comprehensive assessment and how using LSA can meet multiple needs within this assessment. LSA can document students' meaningful participation in their daily life through assessment of their language used during everyday tasks. The many advances in computerized LSA are detailed with a primary focus on the Systematic Analysis of Language Transcripts (Miller & Iglesias, 2019). The LSA process is reviewed detailing the steps necessary for computers to calculate word, morpheme, utterance, and discourse features of functional language. Conclusion These advances in computer technology and software development have made LSA clinically feasible through standardized elicitation and transcription methods that improve accuracy and repeatability. In addition to improved accuracy, validity, and reliability of LSA, databases of typical speakers to document status and automated report writing more than justify the time required. Software now provides many innovations that make LSA simpler and more accessible for clinical use. Supplemental Material https://doi.org/10.23641/asha.12456719


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Ananthakrishna Thalengala ◽  
Shyamasunder N. Bhat ◽  
H. Anitha

AbstractAnalysis of scoliosis requires thorough radiographic evaluation by spinal curvature estimation to completely assess the spinal deformity. Spinal curvature estimation gives orthopaedic surgeons an idea of severity of spinal deformity for therapeutic purposes. Manual intervention has always been an issue to ensure accuracy and repeatability. Computer assisted systems are semi-automatic and is still influenced by surgeon’s expertise. Spinal curvature estimation completely relies on accurate identification of required end vertebrae like superior end-vertebra, inferior end-vertebra and apical vertebra. In the present work, automatic extraction of spinal information central sacral line and medial axis by computerized image understanding system has been proposed. The inter-observer variability in the anatomical landmark identification is quantified using Kappa statistic. The resultant Kappa value computed between proposed algorithm and observer lies in the range 0.7 and 0.9, which shows good accuracy. Identification of the required end vertebra is automated by the extracted spinal information. Difference in inter and intra-observer variability for the state of the art computer assisted and proposed system are quantified in terms of mean absolute difference for the various types (Type-I, Type-II, Type-III, Type-IV, and Type-V) of scoliosis.


Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4852
Author(s):  
Grzegorz Bomba ◽  
Artur Ornat ◽  
Piotr Gierlak

The article discusses the quality testing of a measuring system consisting of a CNC machine with measuring probes. The research was conducted in a broader context regarding the implementation of the closed door technology, i.e., production without human intervention, in an aviation plant manufacturing aircraft gearbox systems. This technology may involve automated measuring operations performed in machining centers, and not in measuring laboratories, provided that the quality of the measurements is appropriate. The aim of the study was to investigate whether the CNC machining device can be used to measure the geometric features of aircraft gearbox housing. For this purpose, measurement experiments were carried out with the use of three different probes. Measurements were carried out using four sequences of increasing complexity, so that, after error analysis, it was possible to find the causes of possible irregularities. A reference ring with known dimensions and position in the working space of the machine was used for the measurements performed as part of the assessment of the measurement system. The quality of the measurements was evaluated with the use of repeatability and reproducibility testing and statistical process control. The analysis results showed that the tested measurement system ensures adequate accuracy and repeatability, and the measurement process is characterized with adequate efficiency in relation to the manufacturing tolerance of the components produced using the machine. Thus, it was proven that the measurement process can be carried out on a machining device, which enables its integration into the closed door technology.


2020 ◽  
Vol 48 (12) ◽  
pp. 030006052096777
Author(s):  
Peisong Chen ◽  
Xuegao Yu ◽  
Hao Huang ◽  
Wentao Zeng ◽  
Xiaohong He ◽  
...  

Introduction To evaluate a next-generation sequencing (NGS) workflow in the screening and diagnosis of thalassemia. Methods In this prospective study, blood samples were obtained from people undergoing genetic screening for thalassemia at our centre in Guangzhou, China. Genomic DNA was polymerase chain reaction (PCR)-amplified and sequenced using the Ion Torrent system and results compared with traditional genetic analyses. Results Of the 359 subjects, 148 (41%) were confirmed to have thalassemia. Variant detection identified 35 different types including the most common. Identification of the mutational sites by NGS were consistent with those identified by Sanger sequencing and Gap-PCR. The sensitivity and specificities of the Ion Torrent NGS were 100%. In a separate test of 16 samples, results were consistent when repeated ten times. Conclusion Our NGS workflow based on the Ion Torrent sequencer was successful in the detection of large deletions and non-deletional defects in thalassemia with high accuracy and repeatability.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Hiroki Shiba ◽  
Yuji Sato ◽  
Junichi Furuya ◽  
Tokiko Osawa ◽  
Akio Isobe ◽  
...  

Abstract Background Screw breakage and loosening are the most common mechanical complications associated with implant treatment, and they may occur due to excess or inadequate screw tightening torque. When fastening and fixing the implant superstructure, screws are tightened using a torque wrench, which is essential for an accurate tightening force. However, the characteristics of the torque wrench have not been fully verified. Therefore, we aimed to clarify the factors affecting the torque with a focus on beam-type torque wrenches, which are the main types of wrenches. Methods The torque values generated by beam-type torque wrenches from eight manufacturers were measured using a torque gauge. To investigate the influence of the location of the beam relative to the scale, measurements were performed with a scale aligned with the trailing edge, center, and leading edge of the beam respectively. Additionally, measurements were taken at 90°, 60°, and 30° to examine the effect of the angle at which the examiner read the torque value. Under each condition, a single examiner applied the recommended torque to each manufacturer's screws five times in a clockwise direction. The average measured torque, standard deviation, bias, and coefficient of variation were calculated and compared accordingly. Results Wrenches from six manufacturers demonstrated excellent accuracy for measurements at the center of the beam (bias within ± 4%). For measurements at 90°, equipments from five manufacturers displayed excellent accuracy (bias within ± 7%), and seven showed excellent repeatability (coefficient of variation ≤ 2%). Conclusion The scale should be aligned with the center of the beam and read from 90° while using a torque wrench. The accuracy and repeatability torques generated by the wrenches differed according to the manufacturer, scale width, scale line width, beam width, and distance between the scale and beam center. Based on these results, we suggest that a torque wrench must be selected after determining the difference in the structure of the torque wrench.


2021 ◽  
Vol 10 (9) ◽  
pp. 1804
Author(s):  
Jorge Posada-Ordax ◽  
Julia Cosin-Matamoros ◽  
Marta Elena Losa-Iglesias ◽  
Ricardo Becerro-de-Bengoa-Vallejo ◽  
Laura Esteban-Gonzalo ◽  
...  

In recent years, interest in finding alternatives for the evaluation of mobility has increased. Inertial measurement units (IMUs) stand out for their portability, size, and low price. The objective of this study was to examine the accuracy and repeatability of a commercially available IMU under controlled conditions in healthy subjects. A total of 36 subjects, including 17 males and 19 females were analyzed with a Wiva Science IMU in a corridor test while walking for 10 m and in a threadmill at 1.6 km/h, 2.4 km/h, 3.2 km/h, 4 km/h, and 4.8 km/h for one minute. We found no difference when we compared the variables at 4 km/h and 4.8 km/h. However, we found greater differences and errors at 1.6 km/h, 2.4 km/h and 3.2 km/h, and the latter one (1.6 km/h) generated more error. The main conclusion is that the Wiva Science IMU is reliable at high speeds but loses reliability at low speeds.


Sign in / Sign up

Export Citation Format

Share Document