scholarly journals Development of a loop-mediated isothermal amplification assay for rapid detection of African swine fever

2020 ◽  
Vol 19 (1) ◽  
pp. 87-100
Author(s):  
Arphaphorn Dokphut ◽  
◽  
Prakit Boonpornprasert ◽  
Tapanut Songkasupa ◽  
Supansa Tangdee ◽  
...  

Since the first African swine fever (ASF) outbreak was reported in China in 2018, the disease has spread rapidly to several countries in Asia. The early detection of this disease is essential for the ASF control strategy to be effective. Loop-mediated isothermal amplification (LAMP) is a nucleic acid detection assay that is rapid, simple, cost-effective and field-friendly. In this study, we have developed a colorimetric assay of LAMP to detect ASF virus (ASFV). A set of LAMP primers was designed to target the conserved region of the VP72 gene. The conditions of LAMP were optimized. The amplification products were easily detected by the naked eye using hydroxynaphthol blue (HNB). The positive LAMP reaction generated a violet to sky blue color change. The sensitivity and specificity of LAMP assay were demonstrated in comparison with the OIE-recommended real-time PCR. A total of 211 samples including 121 confiscated pork products and 90 spiked clinical specimens were tested. The optimal amplification of ASFV DNA by LAMP was incubation at 60 °C for 90 min. The analytical sensitivity of ASFV LAMP assay was at least 368 plasmid DNA copies/µL without cross-reactivity with other swine pathogens. The diagnostic sensitivity and specificity of LAMP were 88% and 100%, respectively. There was almost perfect agreement between LAMP and real-time PCR assays (Kappa value=0.84). This novel LAMP assay is deemed to be a rapid, simple, sensitive, specific diagnostic tool and suitable for early detection of ASF to minimize the likelihood of ASF spread nationwide.

PLoS ONE ◽  
2021 ◽  
Vol 16 (1) ◽  
pp. e0244753
Author(s):  
Jeeyong Kim ◽  
Borae G. Park ◽  
Da Hye Lim ◽  
Woong Sik Jang ◽  
Jeonghun Nam ◽  
...  

Introduction The rapid and accurate diagnosis of tuberculosis (TB) is important to reduce morbidity and mortality rates and risk of transmission. Therefore, molecular detection methods such as a real-time PCR–based assay for Mycobacterium tuberculosis (MTB) have been commonly used for diagnosis of TB. Loop-mediated isothermal amplification (LAMP) assay was believed to be a simple, quick, and cost-effective isothermal nucleic acid amplification diagnostic test for infectious diseases. In this study, we designed an in-house multiplex LAMP assay for the differential detection of MTB and non-tuberculosis mycobacterium (NTM), and evaluated the assay using clinical samples. Material and methods For the multiplex LAMP assay, two sets of specific primers were designed: the first one was specific for IS6110 genes of MTB, and the second one was universal for rpoB genes of mycobacterium species including NTM. MTB was confirmed with a positive reaction with both primer sets, and NTM was identified with a positive reaction by only the second primer set without a MTB-specific reaction. Total 333 clinical samples were analyzed to evaluate the multiplex LAMP assay. Clinical samples were composed of 195 positive samples (72 MTB and 123NTM) and 138 negative samples. All samples were confirmed positivity or negativity by real-time PCR for MTB and NTM. Analytical sensitivity and specificity were evaluated for the multiplex LAMP assay in comparison with acid fast bacilli staining and the culture method. Results Of 123 NTM samples, 121 were identified as NTM and 72/72 MTB were identified as MTB by the multiplex LAMP assay. False negative reactions were seen only in two NTM positive samples with co-infection of Candida spp. All 138 negative samples were identified as negative for MTB and NTM. Analytical sensitivity of the multiplex LAMP assay was 100% (72/72) for MTB, and 98.4% (121/123) for NTM. And the specificity of assay was 100% (138/138) for all. Conclusions Our newly designed multiplex LAMP assay for MTB and NTM showed relatively good sensitivity in comparison with previously published data to detect isolated MTB. This multiplex LAMP assay is expected to become a useful tool for detecting and differentiating MTB from NTM rapidly at an acceptable sensitivity.


2011 ◽  
Vol 47 (No. 4) ◽  
pp. 140-148 ◽  
Author(s):  
N. Rostamkhani ◽  
A. Haghnazari ◽  
M. Tohidfar ◽  
A. Moradi

In an attempt to speed up the process of screening of transgenic cotton (G. hirsutum L.) plants, a visual and rapid loop-mediated isothermal amplification (LAMP) assay was adopted. Genomic DNA was extracted from fresh leaf tissues of T<sub>2</sub> transgenic cotton containing chitinase (chi) and cry1A(b) genes. Detection of genes of interest was performed by polymerase chain reaction (PCR), LAMP and real-time PCR methods. In LAMP assay the amplification was performed after 30 min at 65&deg;C when loop primers were involved in the reaction. The involvement of loop primers decreased the time needed for amplification. By testing serial tenfold dilutions (10<sup>&ndash;1</sup> to 10<sup>&ndash;8</sup>) of the genes of interest, the detection sensitivity of LAMP was found to be 100-fold higher than that of PCR. The rapid DNA extraction method and LAMP assay can be performed within 30 min and the derived LAMP products can be directly observed as visually detectable based on turbidity in the reaction tube. The accuracy of LAMP method in the screening of transgenes was confirmed by PCR and real-time PCR. The developed method was efficient, rapid and sensitive in the screening of cotton transgenic plants. This method can be applied to any other crops.


2019 ◽  
Vol 57 (4) ◽  
Author(s):  
Matthew R. Watts ◽  
Rady Kim ◽  
Vishal Ahuja ◽  
Gemma J. Robertson ◽  
Yasmin Sultana ◽  
...  

ABSTRACTStrongyloides stercoraliscan cause disease that ranges from asymptomatic chronic infection to fatal hyperinfection. Diagnosis from stool can be challenging because the most sensitive conventional tests require live larvae to be effective and there can be low larval output in chronic infection. Nucleic acid amplification tests (NAAT) have been developed to complement existing diagnostic methods. We compared a recently developed loop-mediated isothermal amplification (LAMP) assay with a real-time PCR that has previously been validated with larval microscopy. The limits of detection—quantified using serial dilutions of DNA extracts from singleStrongyloides rattithird-stage (L3) larvae spiked into approximately 250 µl of 5 differentS. stercoralis-negative stool specimens—were 10−3(1/5 replicates) and 10−2(1/5 replicates) dilutions for PCR and LAMP, respectively. PCR was positive for 4/5 replicates at 10−2. LAMP was compared to PCR using extracts from 396 stool specimens collected in Bangladesh and Australia, of which 53 were positive and 343 were negative by PCR. The positive percentage agreement of LAMP was 77.3% (95% score confidence interval [CI], 64.5 to 86.6). The negative percentage agreement was 100% (95% CI, 98.9 to 100). In a preliminary investigation, PCR and LAMP assays were positive using DNA extracted from serum (PCR, 3/16 extracts; LAMP, 2/16 extracts) and bronchoalveolar lavage fluid (PCR and LAMP, 2/2 extracts), demonstrating proof of concept. Compared to PCR, the lower number of positive results using the LAMP assay may have been due to reaction inhibitors and DNA degradation, and strategies to improve the LAMP assay are discussed.


2017 ◽  
Vol 100 (1) ◽  
pp. 99-103 ◽  
Author(s):  
Xinyue Zhang ◽  
Guojie Xu ◽  
Huaqi Tang ◽  
Yanpeng Li ◽  
Chunsheng Liu

Abstract Fungi of the Alternaria genus are associated with allergic diseases, with Alternaria alternata being one of the most prevalent species. A. alternata has been frequently reported as the etiologic agent of hypersensitivity pneumonitis, allergic rhinosinusitis, bronchial asthma,and other diseases. In this study, we developed a loop-mediated isothermal amplification (LAMP) assay and a real-time PCR assay to detect low levels of A. alternata in herbal tea samples. The LAMP assay can detect as little as 3 pg/μL of A. alternata genomic DNA with high specificity. In addition, both the LAMP assay and the real-time PCR assay can be used for quantification of A. alternata. Although the newly developed LAMP assay is more rapid and specific in A. alternata identification, the real-time PCR assay is more precise in quantitation analysis.


2011 ◽  
Vol 24 (1) ◽  
pp. 138-141 ◽  
Author(s):  
Shan-Chia Ou ◽  
Joseph J. Giambrone ◽  
Kenneth S. Macklin

A TaqMan real-time polymerase chain reaction (PCR) and loop-mediated isothermal amplification (LAMP) assay were developed to detect Gallid herpesvirus 1 (GaHV-1, formerly Infectious laryngotracheitis virus). The standard curve of real-time PCR was established, and the sensitivity reached 10 copies/μl. In the current study, the conversion between viral titer and GaHV-1 genomic copy number was constructed. Six primers for LAMP assay amplified target gene at 65°C within 45 min, and the detection limit was 60 copies/μl. The 6 primers were highly specific, sensitive, and reproducible for detection of GaHV-1. Although the sensitivity of LAMP was lower than that of real-time PCR, LAMP was faster, less expensive, and did not require a thermocycler. The LAMP assay would be a viable alternative assay in diagnostic laboratories that do not employ real-time PCR technology.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0247618
Author(s):  
Yuta Mikami ◽  
Kazumasa Fuwa ◽  
Eriko Arima ◽  
Yasuo Suda ◽  
Itaru Yanagihara ◽  
...  

Introduction A simple and rapid diagnosis of Ureaplasma spp. is required for the choice of the appropriate antibiotic. However, an ideal detection method has not been available. This study examines the efficacy of the loop-mediated isothermal amplification (LAMP) assay, which provides rapid and sensitive results, to detect Ureaplasma spp. in respiratory tract samples of preterm infants. Methods The study included preterm infants born before 32 weeks of gestation admitted Kagoshima City Hospital from June 2018 to March 2020. Nasopharyngeal swabs and/or tracheal aspirates were obtained in the first seven postnatal days. One hundred sixty-seven nasopharyngeal swabs and 101 tracheal aspirates were analyzed by LAMP, culture, and quantitative real-time polymerase chain reaction. Results All 167 infants had a median (range) gestational age of 28.7 weeks (22.3–30.9) and birthweight 1030g (322–1828). One hundred sixty-seven nasopharyngeal swabs and 101 tracheal aspirates were obtained. In the results of nasopharyngeal swabs, the sensitivity and specificity of LAMP were 73.9% (17/23) and 97.2% (140/144), whereas those of quantitative real-time polymerase chain reaction were 73.9% (17/23) and 95.8% (138/144), compared to culture. In the results of tracheal aspirates, the sensitivity and specificity of LAMP were 89.5% (17/19) and 92.7% (76/82), whereas those of quantitative real-time polymerase chain reaction were 89.5% (17/19) and 93.9% (77/82), compared to culture. Conclusions The LAMP assay showed similar sensitivity and specificity with quantitative real-time polymerase chain reaction in the respiratory tracts of preterm infants including extremely preterm infants during the immediate postnatal period. Therefore, the LAMP is a practical alternative for the early detection so that appropriate antibiotics can be administered for preventing BPD.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248042
Author(s):  
Woong Sik Jang ◽  
Da Hye Lim ◽  
Jung Yoon ◽  
Ahran Kim ◽  
Minsup Lim ◽  
...  

A newly identified coronavirus, designated as severe acute respiratory syndrome coronavirus 2 (SARS CoV-2), has spread rapidly from its epicenter in China to more than 150 countries across six continents. In this study, we have designed three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) primer sets to detect the RNA-dependent RNA polymerase (RdRP), Envelope (E) and Nucleocapsid protein (N) genes of SARS CoV-2. For one tube reaction, the detection limits for five combination SARS CoV-2 LAMP primer sets (RdRP/E, RdRP/N, E/N, RdRP/E/N and RdRP/N/Internal control (actin beta)) were evaluated with a clinical nasopharyngeal swab sample. Among the five combination, the RdRP/E and RdRP/N/IC multiplex LAMP assays showed low detection limits. The sensitivity and specificity of the RT-LAMP assay were evaluated and compared to that of the widely used Allplex™ 2019-nCoV Assay (Seegene, Inc., Seoul, South Korea) and PowerChek™ 2019-nCoV Real-time PCR kit (Kogenebiotech, Seoul, South Korea) for 130 clinical samples from 91 SARS CoV-2 patients and 162 NP specimens from individuals with (72) and without (90) viral respiratory infections. The multiplex RdRP (FAM)/N (CY5)/IC (Hex) RT-LAMP assay showed comparable sensitivities (RdRP: 93.85%, N: 94.62% and RdRP/N: 96.92%) to that of the Allplex™ 2019-nCoV Assay (100%) and superior to those of PowerChek™ 2019-nCoV Real-time PCR kit (RdRP: 92.31%, E: 93.85% and RdRP/E: 95.38%).


2015 ◽  
Vol 65 (1) ◽  
pp. 20-29 ◽  
Author(s):  
PARK Byung-Yong ◽  
SHIM Kwan-Seob ◽  
KIM Won-Il ◽  
HOSSAIN Md Mukter ◽  
KIM Bumseok ◽  
...  

Abstract A simple and rapid real-time loop-mediated isothermal amplification (LAMP) assay designed to detect Lawsonia (L.) intracellularis, an important bacteria causing proliferative enteropathy in pigs. A set of four primers targeting the ubiquinone/menaquinone biosynthesis methylase (ubiE) gene was designed for the LAMP reaction. Additionally, serial 10-fold dilutions of cultured L. intracellularis and spiked feces were also used for the optimization of real-time LAMP. The lower limit of the linear range of the assay in L. intracellularis was 1.0 × 100 L. intracellularis. Real-time LAMP was 10 and 100 times more sensitive than real-time PCR and conventional PCR detection methods, respectively. Based on testing of 213 porcine fecal samples using real-time LAMP, realtime PCR and PCR, the agreement quotients of real-time LAMP with conventional PCR and with real-time PCR were 0.77 and 0.95, respectively. This study demonstrated that real-time LAMP was a powerful tool for the rapid and sensitive detection of L. intracellularis in porcine fecal samples.


Sign in / Sign up

Export Citation Format

Share Document