AWWA C514-20 Air Valve and Vent Inflow Preventer Assemblies for Potable Water Distribution System and Storage Facilities

2021 ◽  
Author(s):  
2008 ◽  
Vol 8 (4) ◽  
pp. 421-426
Author(s):  
J. Menaia ◽  
M. Benoliel ◽  
A. Lopes ◽  
C. Neto ◽  
E. Ferreira ◽  
...  

Concerns arise from the possible occurrence of pathogens in drinking water pipe biofilms and storage tank sediments. In these studies, biofilm samples from pipes and sediments from storage tanks of the Lisbon drinking water distribution system were analyzed. Protein determinations and heterotrophic counts on pipe biofilm samples were used to assess the Lisbon network sessile colonization intensity and distribution. Indicator and pathogenic microorganisms were analyzed in pipe biofilm samples, as well as in storage tanks biofilm and sediments, by using cultural methods and PCR, to assess risks. Results have shown that the Lisbon network sessile colonization is relatively weak in intensity. In addition, no meaningful hazards were apparent for both the network biofilm and the storage tanks biofilm and sediments.


2010 ◽  
Vol 16 (1-3) ◽  
pp. 427-438 ◽  
Author(s):  
Phillip A. Lintereur ◽  
Steven J. Duranceau ◽  
James S. Taylor ◽  
Erica D. Stone

Author(s):  
Berge Djebedjian ◽  
Ahmed Herrick ◽  
Magdy Abou Rayan

A potable water network hydraulic analysis is presented in this paper. A mathematical model was developed, the model treats looped network. A computer program is developed in order to facilitate water distribution system design, which satisfies all constraints including pipe diameter and nodal pressure. An optimization technique is developed in order to evaluate the optimum network configuration and cost, the parameters are pipe diameter, flow rate, corresponding pressure and hydraulic losses. A non-linear technique was adopted in the solution. The model uses the sequential unconstrained minimization technique (SUMT) of Fiacco and McCormick (1964) to solve the optimal design of network. The adopted optimization technique decreases the required number of design iterations which for example may reach 1.48 billion iterations for a network with 8 pipes and a set of 14 available commercial pipes. The initially assumed pipe diameters are successively adjusted to suit the existing standard commercial pipe diameters. The technique was applied on a simple case study of gravity-fed network. The objective of the present investigation is to present a practical tool to help in the optimization of water distribution system, design and operation.


2020 ◽  
Vol 11 (4) ◽  
pp. 04020046
Author(s):  
Daniela Rojas ◽  
Kevin Vargas ◽  
Andrés Cortés ◽  
Sebastián Rocha ◽  
Pablo París ◽  
...  

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Diana Rita Nanyanzi ◽  
Gilbert Gilibrays Ocen ◽  
Timothy Omara ◽  
Felix Bwire ◽  
Davis Matovu ◽  
...  

Abstract Objective The aim of this study was to design a domestic water temperature, pH and turbidity monitoring system that could constantly log temperature, pH and turbidity of water and give alerts in case the parameters are outside the acceptable limits for potable water. Results The system was designed, assembled and performed as expected. The study indicates that the proposed and designed system outperforms the existing manual monitoring system as it can constantly track and store changes in water quality. This could be used to prepare better treatment processes as well as identify problems in the water distribution system early enough.


2020 ◽  
Vol 17 (4) ◽  
pp. 113-117
Author(s):  
Rajanbir Kaur ◽  
Rajinder Kaur

Microbes are ubiquitous in surface as well as in ground water and some of them can make their way into potable water distribution systems. Contaminated soil with human and animal fecal matter, ill-maintained water and sewage pipelines, poor sanitation and personal hygiene are the main factors responsible for the presence of microbial pathogens in the drinking water. The presence of water-borne microbes in the potable drinking water systems determines its quality. Common microbes present in contaminated water are Shigella, Escherichia coli, Vibrio cholerae, Pseudomonas sp, Salmonella sp etc. The water-borne pathogens that reside and reproduce in water distribution system causes infection of gastrointestinal tract, urinary tract, skin, and lymph nodes. When these pathogens enter into the water distribution system pipelines they form biofilms. The formation of biofilm is a key component in microbial studies. Biofilm is the sessile aggregation of bacterial cells that adhere to each other on living or non-living surfaces and forms extracellular polymeric substances (EPS). The surface physico-chemical properties of both bacteria and substratum were important for the establishment of bacterial adhesion. Bacteria forming biofilms possesses different growth patterns, responds to specific micro-environmental conditions for the formation of structurally complex mature biofilms. In water distribution systems, adhesion of microbes to the water pipelines initiate biofilm formation which in return reduces the quality of potable water and increases the corrosion of pipes.


2021 ◽  
Vol 11 (2) ◽  
Author(s):  
Paweł Suchorab ◽  
Małgorzata Iwanek ◽  
Agnieszka Żelazna

AbstractThe most important goal of every water distribution system is to deliver water to the consumers in the demand and time determined by its users. However, not all water usages require the potable water quality. One of the technical solutions enabling water recycling and its reuse is a dual installation system. Dual installations recycle rain wastewater or grey water from bathtubs, showers and sinks and further reuse it for irrigation or toilet flushing. The profitability of a dual installation system is highly dependent on the water price, which tends to vary significantly according to the location. The purpose of this paper is to evaluate the profitability of dual installation systems in exemplary hotel building hypothetically located in 10 different European countries. The profitability was determined on the basis of multi-criteria decision analysis performed for two installation variants. The investment was evaluated in terms of technical, economic and environmental aspects. As a result, the selected countries were ranked in order of the most profitable location for dual installation system’s investment.


Sign in / Sign up

Export Citation Format

Share Document