scholarly journals Numerical simulation of an osteoporotic femur

Author(s):  
Mohamed Tellache ◽  
Emmanuel Rixrath ◽  
Patrick Chabrand ◽  
Christian Hochard ◽  
Martine Pithioux ◽  
...  

Bone remodelling adapts bone geometry and properties under supported loadings. This optimization process is deteriorated by metabolic diseases like osteoporosis which involves femoral neck fractures and implies Total Hip Arthroplasty. Two finite element models are developed to evaluate the stress distribution within osteoporotic human femur bone tissue, and its influence on the stem stability. The geometries of human femur and prosthesis are obtained by helicoid scanner acquisition. The cortical bone was separated from the trabecular bone by apparent density threshold. The results obtained for osteoporotic femur show that the degradation of trabecular architecture causes high stresses in the anteroinferior zone of the cortical bone. For the femur with hip prosthesis, high stresses weak the bone tissue in the lateral zone of the proximal dyaphisis and in the medial zone of the distal part at the end of the stem.

2009 ◽  
Vol 2 (3) ◽  
pp. 255-263 ◽  
Author(s):  
Alejandro A. Espinoza Orías ◽  
Justin M. Deuerling ◽  
Matthew D. Landrigan ◽  
John E. Renaud ◽  
Ryan K. Roeder

2008 ◽  
Vol 136 ◽  
pp. S410
Author(s):  
Zhenbing Cai ◽  
Minhao Zhu ◽  
Haiyang Yu ◽  
Huoming Shen ◽  
Qian Huang ◽  
...  

2021 ◽  
pp. 38-40
Author(s):  
O.Yu. Rivis ◽  
V.S. Melnyk ◽  
M.V. Rivis ◽  
K.V. Zombor

The aim of the study. Carry out a comparative analysis of the support ability of human jaw bone tissue in monocortical and bicortical installation of a mini-implant of own design OMG. Research methods. In order to study biomechanical characteristics of developed OMG mini-implant and bone tissue capacity during monocortical and bicortical installation, the finite element method (MSE) was used. The scheme and finite element 2-D model of bicortical installation of OMG mini-implant (length 8 mm, diameter 1.8 mm) provided full penetration through one layer of cortical bone equal to 1 mm, the entire cancellous bone and immersion in the second layer of cortical bone by 0, 5 mm. No implantation was immersed in the second cortical layer of bone during monocortical installation. A single force load of 1 N was applied in the horizontal direction parallel to the cortical plate of the bone. Results of the study. One of the most important factors leading to the success of the use of a mini-implant is its stability in the process of orthodontic treatment. Quite a high level of failure in the monocortical installation of mini-screws has led to the search for better methods to ensure the stability of their use. This was a bicortical method of fixation, based on the placement of the minig screw in the thickness of the two cortical plates of the jaws. Area for such installation of mini-screws can be a site of a palate and alveolar sprouts at installation of miniimplants through all its thickness. As shown by our data on the use of the finite element method under the force load of the biomechanical system "bone - mini-implant", the stress concentration zone is located in the area of the cortical bone of the jaw. The results of the calculation of the maximum stresses (σmax, MPa) and the maximum possible displacements (umax, mm) of the mini-implant in the biomechanical system "bone - mini-implant" in monocortical installation were, respectively, 8.27 MPa and 0.300 * 10-8 mm and in bicortical installation 6.00 MPa and 0.201 * 10-8 mm. The bicortical method of fixing the mini-implant in the jaw bones significantly increases the ability to resist deformation of this type of biomechanical system under force loads of the mini-implant. In the bicortical method of mini-implant placement, the extreme values of equivalent according to Mises stresses in the upper part of the cortical bone of the jaw are reduced by 27%. This can be explained by a significant increase in the area of contact due to the two layers of the cortical bone of the jaw with the surface of the mini-implant. Conclusion. The bicortical method of installing mini-implants is a more effective and reliable way to provide skeletal support during orthodontic treatment.


Bone ◽  
2009 ◽  
Vol 44 ◽  
pp. S99-S100
Author(s):  
C.A. Bailey ◽  
S. Kukuljan ◽  
R.M. Daly

Author(s):  
Yener N. Yeni ◽  
Roger R. Zauel

Cortical bone tissue quality is imperative in maintaining the mechanical competence of whole bones, particularly at sites of overuse and age-related fragility fractures where a considerable cortical bone component is present. (Note that cortical bone tissue is more than 80% of the bone in the body [1].)


2019 ◽  
Vol 34 (8) ◽  
pp. 1446-1450
Author(s):  
Joseph M Kindler ◽  
Emma M Laing ◽  
Weixi Liu ◽  
Joel A Dain ◽  
Richard D Lewis

Sign in / Sign up

Export Citation Format

Share Document