Reactor Containment Heat Removal by Passive Heat Sinks Following a Loss-of-Coolant Accident

1977 ◽  
Vol 33 (3) ◽  
pp. 243-247 ◽  
Author(s):  
P. S. Ayyaswamy ◽  
J. N. Chung ◽  
K. K. Niyogi
Author(s):  
S. P. Saraswat ◽  
P. Munshi ◽  
A. Khanna ◽  
C. Allison

The initial design of ITER incorporated the use of carbon fiber composites in high heat flux regions and tungsten was used for low heat flux regions. The current design includes tungsten for both these regions. The present work includes thermal hydraulic modeling and analysis of ex-vessel loss of coolant accident (LOCA) for the divertor (DIV) cooling system. The purpose of this study is to show that the new concept of full tungsten divertor is able to withstand in the accident scenarios. The code used in this study is RELAP/SCADAPSIM/MOD 4.0. A parametric study is also carried out with different in-vessel break sizes and ex-vessel break locations. The analysis discusses a number of safety concerns that may result from the accident scenarios. These concerns include vacuum vessel (VV) pressurization, divertor temperature profile, passive decay heat removal capability of structure, and pressurization of tokamak cooling water system. The results show that the pressures and temperatures are kept below design limits prescribed by ITER organization.


Author(s):  
T. Gocht ◽  
W. Kästner ◽  
A. Kratzsch ◽  
M. Strasser

In case of an accident the safe heat removal from the reactor core with the installed emergency core cooling system (ECCS) is one of the main features in reactor safety. During a loss-of-coolant accident (LOCA) the release of insulation material fragments in the reactor containment can lead to malfunctions of ECCS. Therefore, the retention of particles by strainers or filtering systems in the ECCS is one of the major tasks. The aim of the presented experimental investigations was the evaluation of a filtering system for the retention of fiber-shaped particles in a fluid flow. The filtering system consists of a filter case with a special lamellar filter unit. The tests were carried out at a test facility with filtering units of different mesh sizes. Insulation material (mineral rock wool) was fragmented to fiber-shaped particles. To simulate the distribution of particle concentration at real plants with large volumes the material was divided into single portions and introduced into the loop with a defined time interval. Material was transported to the filter by the fluid and agglomerated there. The assessment of functionality of the filtering system was made by differential pressure between inlet and outlet of the filtering system and by mass of penetrated particles. It can be concluded that for the tested filtering system no penetration of insulation particles occurred.


2006 ◽  
Vol 33 (5) ◽  
pp. 405-414 ◽  
Author(s):  
Anis Bousbia-salah ◽  
Brahim Meftah ◽  
Tewfik Hamidouche ◽  
El Khider Si-Ahmed

2002 ◽  
Vol 124 (2) ◽  
pp. 161-167 ◽  
Author(s):  
D. Mukhopadhyay ◽  
P. Majumdar ◽  
G. Behera ◽  
S. K. Gupta ◽  
V. Venkat Raj

The reactor channel of the horizontal core of pressurized heavy water reactors experiences very low sustained flow during loss of coolant accident (LOCA) at the reactor inlet feeders caused by certain breaks known as critical channel breaks. In this type of accident the reactor trip is delayed causing a gross mismatch of the heat generation and heat removal in the channel, thus leading to rapid temperature rise in the affected channel. A study has been carried out to identify the phenomena and the break size leading to such a situation. Severe fuel damage is predicted in the channel.


2021 ◽  
Vol 2021 ◽  
pp. 1-17
Author(s):  
F. Ameyaw ◽  
R. Abrefah ◽  
S. Yamoah ◽  
S. Birikorang

Fault trees (FT) and event trees (ET) are widely used in industry to model and evaluate the reliability of safety systems. This work seeks to analyze and estimate the core damage frequency (CDF) due to flow blockage (FB) and loss of coolant accident (LOCA) due to large rupture of primary circuit pipe with respect to a specific 10 MW Water-Water Research Reactor in Ghana using the FT and ET technique. Using FT, the following reactor safety systems: reactor protection system, primary heat removal system, isolation of the reactor pool, emergency core cooling system (ECCS), natural circulation heat removal, and isolation of the containment were evaluated for their dependability. The probabilistic safety assessment (PSA) Level 1 was conducted using a commercial computational tool, system analysis program for practical coherent reliability assessment (SAPHIRE) 7.0. The frequency of an accident resulting in severe core damage for the internal initiating event was estimated to be 2.51e − 4/yr for the large LOCA as well as 1.45e − 4/yr for FB, culminating in a total core damage frequency of 3.96e − 4/yr. The estimated values for the frequencies of core damage were within the expected margins of 1.0e − 5/yr to 1.0e − 4/yr and of identical sequence of the extent as found for similar reactors.


2021 ◽  
Vol 23 (2) ◽  
Author(s):  
Putu Brahmanda Sudarsana ◽  
Wayan Nata Septiadi ◽  
Mulya Juarsa

SMART (System-Integrated Advanced Modular Reactor) merupakan desain reaktor multifungsi Generasi III+ tipe SMR (Small Modular Reactor) yang dikembangkan oleh KAERI (Korean Atomic Energy Research Institute) dengan kapabilitas produksi listrik 107 MWe dan energi termal 365 MWt. Sistem SMART meliputi berbagai fitur keselamatan untuk mengatasi LOCA (Loss of Coolant Accident) dan skenario kecelakaan lainnya. Salah satu dari fitur tersebut adalah Passive Residual Heat Removal System (PRHRS) atau sistem pembuang sisa panas pasif yang bekerja tanpa membutuhkan sumber daya elektrik. Sistem ini bekerja sesuai dengan prinsip sirkulasi alam sehingga bergantung pada aspek termal, tekanan, dan pengaruhnya terhadap aliran massa. Ketiga aspek tersebut dapat mempengaruhi kapabilitas pembuangan panas pada sistem. Data performa PRHRS reaktor SMART pada beberapa kondisi kecelakaan yang diperoleh melalui studi eksperimental maupun simulasi termohidrolika dianalisis pada kajian ini. Hasil analisis menunjukkan unjuk kerja pembuangan sisa panas yang baik oleh PRHRS SMART dengan waktu aktuasi yang tepat dan pendinginan yang stabil. Dengan kapabilitas multifungsi dan kemampuan pendinginan yang baik pada berbagai skenario kecelakaan, SMART memiliki potensi tinggi untuk kelak diterapkan di Indonesia.


Sign in / Sign up

Export Citation Format

Share Document