Comparison of different calibration methods for Mueller matrix microscopy of cells

2021 ◽  
Vol 60 (5) ◽  
pp. 1380
Author(s):  
Ruoyu Meng ◽  
Zhenhua Chen ◽  
Xingjian Wang ◽  
Yudi Liu ◽  
Honghui He ◽  
...  
2021 ◽  
pp. 45-52
Author(s):  
Evgeny L. Shoshin

Methods of external calibration of radar polarimeters are considered. Algorithms for evaluating elements of the Mueller matrix and eliminating distortions introduced by the polarimeter are presented. The article describes the design of a radar reflector with electrically controlled polarization properties that can imitate the properties of two and three-sided reflectors and non-reciprocal reflectors. The analysis of the mode of dynamic switching of the scattering characteristics of the reflector used for calibration by the method of polarization modulation of scattered signals is performed. The results of experimental studies of a laboratory sample of a radar reflector with controlled characteristics are presented. The results obtained can be used in radar.


2020 ◽  
Vol 10 (13) ◽  
pp. 4422
Author(s):  
Jiewei Yu ◽  
Xuemin Cheng ◽  
Maolin Li

Currently, there are various calibration methods available to reduce the errors caused by the polarizing section of a dual-rotating-retarder polarimeter. Although these methods have high measurement accuracy, their robustness must be improved and the influence of the imaging section needs be discussed when they are applied in Mueller matrix microscopes. In this paper, a method of error source analysis and element calibration for the Mueller matrix microscope is proposed by using error transform coefficient matrices to account for the polarizing effect of the imaging section. Using Taylor expansion, an approximate linear relationship is established between the sources of errors and the Mueller matrix elements of the measured sample. From this relationship, error magnification coefficient matrices are calculated to determine the specific parameter errors in both the polarizing and imaging sections. Furthermore, elements in the fourth row or column of the error magnification coefficient matrix are especially important for the imaging section. The measurement and simulation results for an air sample and a quarter-wave plate sample as the standard samples, as well as a Daphnia organism sample with complex internal structure, are investigated and discussed. Furthermore, the comparison results reveal the effect of the imaging section on the birefringence characteristics of the Mueller matrix. With the proposed method, the maximum error can be reduced to be less than 0.01 for all the matrix elements and for the amplitude parameter of birefringence, even when the two system parameters a 2 and a 3 of the rotating mechanical part deviate from the default.


1999 ◽  
Author(s):  
D. Look, Jr.
Keyword(s):  

Instruments ◽  
2021 ◽  
Vol 5 (1) ◽  
pp. 9
Author(s):  
Sandro Palestini

The subject of space charge in ionization detectors is reviewed, showing how the observations and the formalism used to describe the effects have evolved, starting with applications to calorimeters and reaching recent, large time-projection chambers. General scaling laws, and different ways to present and model the effects are presented. The relations between space-charge effects and the boundary conditions imposed on the side faces of the detector are discussed, together with a design solution that mitigates some of the effects. The implications of the relative size of drift length and transverse detector size are illustrated. Calibration methods are briefly discussed.


2021 ◽  
Vol 42 (3) ◽  
Author(s):  
Rudolf Aro ◽  
Mohamed Wajdi Ben Ayoub ◽  
Ivo Leito ◽  
Éric Georgin ◽  
Benoit Savanier

AbstractIn the field of water content measurement, the calibration of coulometric methods (e.g., coulometric Karl Fischer titration or evolved water vapor analysis) is often overlooked. However, as coulometric water content measurement methods are used to calibrate secondary methods, their results must be obtained with the highest degree of confidence. The utility of calibrating such instruments has been recently demonstrated. Both single and multiple point calibration methods have been suggested. This work compares these calibration methods for the evolved water vapor analysis technique. Two uncertainty estimation approaches (Kragten’s spreadsheet and M-CARE software tool) were compared as well, both based on the ISO GUM method.


Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 765
Author(s):  
Hugo Álvarez ◽  
Marcos Alonso ◽  
Jairo R. Sánchez ◽  
Alberto Izaguirre

This paper describes a method for calibrating multi camera and multi laser 3D triangulation systems, particularly for those using Scheimpflug adapters. Under this configuration, the focus plane of the camera is located at the laser plane, making it difficult to use traditional calibration methods, such as chessboard pattern-based strategies. Our method uses a conical calibration object whose intersections with the laser planes generate stepped line patterns that can be used to calculate the camera-laser homographies. The calibration object has been designed to calibrate scanners for revolving surfaces, but it can be easily extended to linear setups. The experiments carried out show that the proposed system has a precision of 0.1 mm.


Sensors ◽  
2021 ◽  
Vol 21 (4) ◽  
pp. 1500
Author(s):  
Songrui Wei ◽  
Xiaoqi Liao ◽  
Han Zhang ◽  
Jianhua Pang ◽  
Yan Zhou

Fluxgate magnetic sensors are especially important in detecting weak magnetic fields. The mechanism of a fluxgate magnetic sensor is based on Faraday’s law of electromagnetic induction. The structure of a fluxgate magnetic sensor mainly consists of excitation windings, core and sensing windings, similar to the structure of a transformer. To date, they have been applied to many fields such as geophysics and astro-observations, wearable electronic devices and non-destructive testing. In this review, we report the recent progress in both the basic research and applications of fluxgate magnetic sensors, especially in the past two years. Regarding the basic research, we focus on the progress in lowering the noise, better calibration methods and increasing the sensitivity. Concerning applications, we introduce recent work about fluxgate magnetometers on spacecraft, unmanned aerial vehicles, wearable electronic devices and defect detection in coiled tubing. Based on the above work, we hope that we can have a clearer prospect about the future research direction of fluxgate magnetic sensor.


Sign in / Sign up

Export Citation Format

Share Document