Fast Reconstruction Technology of Laser Beam SpatialTransmission Characteristic Curve

2022 ◽  
Author(s):  
Jianing Liu ◽  
Jin Meng ◽  
Jiahang Lyv ◽  
Shifeng Wang
Author(s):  
David W. Piston ◽  
Brian D. Bennett ◽  
Robert G. Summers

Two-photon excitation microscopy (TPEM) provides attractive advantages over confocal microscopy for three-dimensionally resolved fluorescence imaging and photochemistry. Two-photon excitation arises from the simultaneous absorption of two photons in a single quantitized event whose probability is proportional to the square of the instantaneous intensity. For example, two red photons can cause the transition to an excited electronic state normally reached by absorption in the ultraviolet. In practice, two-photon excitation is made possible by the very high local instantaneous intensity provided by a combination of diffraction-limited focusing of a single laser beam in the microscope and the temporal concentration of 100 femtosecond pulses generated by a mode-locked laser. Resultant peak excitation intensities are 106 times greater than the CW intensities used in confocal microscopy, but the pulse duty cycle of 10-5 maintains the average input power on the order of 10 mW, only slightly greater than the power normally used in confocal microscopy.


Author(s):  
Jean-Paul Revel

The last few years have been marked by a series of remarkable developments in microscopy. Perhaps the most amazing of these is the growth of microscopies which use devices where the place of the lens has been taken by probes, which record information about the sample and display it in a spatial from the point of view of the context. From the point of view of the biologist one of the most promising of these microscopies without lenses is the scanned force microscope, aka atomic force microscope.This instrument was invented by Binnig, Quate and Gerber and is a close relative of the scanning tunneling microscope. Today's AFMs consist of a cantilever which bears a sharp point at its end. Often this is a silicon nitride pyramid, but there are many variations, the object of which is to make the tip sharper. A laser beam is directed at the back of the cantilever and is reflected into a split, or quadrant photodiode.


1997 ◽  
Vol 78 (02) ◽  
pp. 794-798 ◽  
Author(s):  
Bowine C Michel ◽  
Philomeen M M Kuijer ◽  
Joseph McDonnell ◽  
Edwin J R van Beek ◽  
Frans F H Rutten ◽  
...  

Summary Background: In order to improve the use of information contained in the medical history and physical examination in patients with suspected pulmonary embolism and a non-high probability ventilation-perfusion scan, we assessed whether a simple, quantitative decision rule could be derived for the diagnosis or exclusion of pulmonary embolism. Methods: In 140 consecutive symptomatic patients with a non- high probability ventilation-perfusion scan and an interpretable pulmonary angiogram, various clinical and lung scan items were collected prospectively and analyzed by multivariate stepwise logistic regression analysis to identify the most informative combination of items. Results: The prevalence of proven pulmonary embolism in the patient population was 27.1%. A decision rule containing the presence of wheezing, previous deep venous thrombosis, recently developed or worsened cough, body temperature above 37° C and multiple defects on the perfusion scan was constructed. For the rule the area under the Receiver Operating Characteristic curve was larger than that of the prior probability of pulmonary embolism as assessed by the physician at presentation (0.76 versus 0.59; p = 0.0097). At the cut-off point with the maximal positive predictive value 2% of the patients scored positive, at the cut-off point with the maximal negative predictive value pulmonary embolism could be excluded in 16% of the patients. Conclusions: We derived a simple decision rule containing 5 easily interpretable variables for the patient population specified. The optimal use of the rule appears to be in the exclusion of pulmonary embolism. Prospective validation of this rule is indicated to confirm its clinical utility.


Sign in / Sign up

Export Citation Format

Share Document