scholarly journals Single-shot ranging and velocimetry with a CW lidar far beyond the coherence length of the CW laser

2021 ◽  
Author(s):  
Mustafa Bayer ◽  
Xun Li ◽  
George Guentchev ◽  
Rasul Torun ◽  
Jose Velazco ◽  
...  
2021 ◽  
Author(s):  
Mustafa Bayer ◽  
Xun Li ◽  
George Guentchev ◽  
Rasul Torun ◽  
Jose E. Velazco ◽  
...  

Abstract The spectral linewidth of the continuous-wave (CW) lasers is one of the key limitations on the coherent lidar systems, which defines the maximum detection range. Furthermore, precise phase or frequency sweeping requirements is a deterrent in many applications. Here, we present the Phase-Based Multi-Tone Continuous Wave (PB-MTCW) lidar measurement technique that eliminates the necessity of using high coherence laser sources as well as any form of phase or frequency sweeping while employing coherent detection. In particular, we modulate a CW laser source with multiple radio-frequency (RF) tones to generate optical sidebands. Then we utilize the relative phase variations between the sidebands that are free from laser phase noises to calculate the target distance via post-processing and triangulation algorithms. We prove that the PB-MTCW technique is capable of performing single-shot ranging and velocimetry measurements at more than 500× the coherence length of a CW laser in a benchtop experimental demonstration.


Author(s):  
T. A. Welton

Various authors have emphasized the spatial information resident in an electron micrograph taken with adequately coherent radiation. In view of the completion of at least one such instrument, this opportunity is taken to summarize the state of the art of processing such micrographs. We use the usual symbols for the aberration coefficients, and supplement these with £ and 6 for the transverse coherence length and the fractional energy spread respectively. He also assume a weak, biologically interesting sample, with principal interest lying in the molecular skeleton remaining after obvious hydrogen loss and other radiation damage has occurred.


1981 ◽  
Vol 4 ◽  
Author(s):  
T. J. Stultz ◽  
J. F. Gibbons

ABSTRACTStructural and electrical characterization of laser recrystallized LPCVD silicon films on amorphous substrates using a shaped cw laser beam have been performed. In comparing the results to data obtained using a circular beam, it was found that a significant increase in grain size can be achieved and that the surface morphology of the shaped beam recrystallized material was much smoother. It was also found that whereas circular beam recrystallized material has a random grain structure, shaped beam material is highly oriented with a <100> texture. Finally the electrical characteristics of the recrystallized film were very good when measured in directions parallel to the grain boundaries.


Author(s):  
L.S. Koh ◽  
H. Marks ◽  
L.K. Ross ◽  
C.M. Chua ◽  
J.C.H. Phang

Abstract A Laser Timing Probe (LTP) system which uses a noninvasive 1.3 µm continuous wave (CW) laser with frequency mapping and single point measurement capabilities is described. The frequency mapping modes facilitate the localization of signal maxima for subsequent single point measurements. Measurements of waveforms with long delays and 50 ps response time from NMOS and PMOS transistors are also shown.


2004 ◽  
pp. 373-380 ◽  
Author(s):  
Timothy D. Solberg ◽  
Steven J. Goetsch ◽  
Michael T. Selch ◽  
William Melega ◽  
Goran Lacan ◽  
...  

Object. The purpose of this work was to investigate the targeting and dosimetric characteristics of a linear accelerator (LINAC) system dedicated for stereotactic radiosurgery compared with those of a commercial gamma knife (GK) unit. Methods. A phantom was rigidly affixed within a Leksell stereotactic frame and axial computerized tomography scans were obtained using an appropriate stereotactic localization device. Treatment plans were performed, film was inserted into a recessed area, and the phantom was positioned and treated according to each treatment plan. In the case of the LINAC system, four 140° arcs, spanning ± 60° of couch rotation, were used. In the case of the GK unit, all 201 sources were left unplugged. Radiation was delivered using 3- and 8-mm LINAC collimators and 4- and 8-mm collimators of the GK unit. Targeting ability was investigated independently on the dedicated LINAC by using a primate model. Measured 50% spot widths for multisource, single-shot radiation exceeded nominal values in all cases by 38 to 70% for the GK unit and 11 to 33% for the LINAC system. Measured offsets were indicative of submillimeter targeting precision on both devices. In primate studies, the appearance of an magnetic resonance imaging—enhancing lesion coincided with the intended target. Conclusions. Radiosurgery performed using the 3-mm collimator of the dedicated LINAC exhibited characteristics that compared favorably with those of a dedicated GK unit. Overall targeting accuracy in the submillimeter range can be achieved, and dose distributions with sharp falloff can be expected for both devices.


Sign in / Sign up

Export Citation Format

Share Document