Heterogeneous integration of Si photodiodes on silicon nitride for near-infrared and visible light detection

2022 ◽  
Author(s):  
Stijn Cuyvers ◽  
Artur Hermans ◽  
Max Kiewiet ◽  
Jeroen Goyvaerts ◽  
Gunther Roelkens ◽  
...  
2020 ◽  
Vol 11 (1) ◽  
pp. 124
Author(s):  
Haibin Geng ◽  
Hanzhe Ye ◽  
Xingliang Chen ◽  
Sibin Du

This paper aims to clarify the phase composition in each sub-layer of tandem absorber TiMoAlON film and verify its thermal stability. The deposited multilayer Ti/(Mo-TiAlN)/(Mo-TiAlON)/Al2O3 films include an infrared reflectance layer, light interference absorptive layers with different metal doping amounts, and an anti-reflectance layer. The layer thicknesses of Ti, Mo-TiAlN, Mo-TiAlON, and Al2O3 are 100, 300, 200, and 80 nm, respectively. Al content increases to 12 at.% and the ratio of N/O is nearly 0.1, which means nitride continuously changes to oxide. According to X-ray Diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM) results, the diffraction peak that appears at 2θ = 40° demonstrates that Mo element aggregates in the substitutional solid solution (Ti,Al)(O,N) columnar grain. TiMoAlON films have low reflectivity in the spectrum range of 300–900 nm. When Al content is more than 10 at.%, absorptivity is almost in the spectrum range from visible to infrared, but absorptivity decreases in the ultraviolet spectrum range. When Al content is increased to 12 at.%, absorptivity α decreases by 0.05 in the experimental conditions. After baking in atmosphere at 500 °C for 8 h, the film has the highest absorptivity when doped with 2 at.% Mo. In the visible-light range, α = 0.97, and in the whole ultraviolet-visible-light near-infrared spectrum range, α = 0.94, and emissivity ε = 0.02 at room temperature and ε = 0.10 at 500 °C.


Author(s):  
Pin-Yi Chen ◽  
Cheng-Sao Chen ◽  
Yueh-Sheng Chiang ◽  
Yi-Shin Jou ◽  
R.R. Chien ◽  
...  

2020 ◽  
Vol 8 (1) ◽  
pp. 165-172 ◽  
Author(s):  
Dongwoo Kim ◽  
Yeong-gyu Kim ◽  
Byung Ha Kang ◽  
Jin Hyeok Lee ◽  
Jusung Chung ◽  
...  

Visible light detection of oxide phototransistors via insertion of an oxide-mesh inside the channel creating oxygen vacancies that increase subgap states.


2012 ◽  
Vol 112 (1) ◽  
pp. 26-32 ◽  
Author(s):  
Shunsaku Koga ◽  
Yutaka Kano ◽  
Thomas J. Barstow ◽  
Leonardo F. Ferreira ◽  
Etsuko Ohmae ◽  
...  

The overarching presumption with near-infrared spectroscopy measurement of muscle deoxygenation is that the signal reflects predominantly the intramuscular microcirculatory compartment rather than intramyocyte myoglobin (Mb). To test this hypothesis, we compared the kinetics profile of muscle deoxygenation using visible light spectroscopy (suitable for the superficial fiber layers) with that for microvascular O2 partial pressure (i.e., PmvO2, phosphorescence quenching) within the same muscle region (0.5∼1 mm depth) during transitions from rest to electrically stimulated contractions in the gastrocnemius of male Wistar rats ( n = 14). Both responses could be modeled by a time delay (TD), followed by a close-to-exponential change to the new steady level. However, the TD for the muscle deoxygenation profile was significantly longer compared with that for the phosphorescence-quenching PmvO2 [8.6 ± 1.4 and 2.7 ± 0.6 s (means ± SE) for the deoxygenation and PmvO2, respectively; P < 0.05]. The time constants (τ) of the responses were not different (8.8 ± 4.7 and 11.2 ± 1.8 s for the deoxygenation and PmvO2, respectively). These disparate (TD) responses suggest that the deoxygenation characteristics of Mb extend the TD, thereby increasing the duration (number of contractions) before the onset of muscle deoxygenation. However, this effect was insufficient to increase the mean response time. Somewhat differently, the muscle deoxygenation response measured using near-infrared spectroscopy in the deeper regions (∼5 mm depth) (∼50% type I Mb-rich, highly oxidative fibers) was slower (τ = 42.3 ± 6.6 s; P < 0.05) than the corresponding value for superficial muscle measured using visible light spectroscopy or PmvO2 and can be explained on the basis of known fiber-type differences in PmvO2 kinetics. These data suggest that, within the superficial and also deeper muscle regions, the τ of the deoxygenation signal may represent a useful index of local O2 extraction kinetics during exercise transients.


2021 ◽  
Author(s):  
Hao Chen ◽  
Lei Lv ◽  
Yanan Wei ◽  
Tianhua Liu ◽  
Song Wang ◽  
...  

2015 ◽  
Vol 44 (34) ◽  
pp. 15212-15219 ◽  
Author(s):  
Lu-Yin Zhang ◽  
Ya-Jun Hou ◽  
Mei Pan ◽  
Ling Chen ◽  
Yi-Xuan Zhu ◽  
...  

Visible light sensitized NIR emission of Nd3+ and Yb3+ by Ru(ii)/Ir(iii) metalloligands is reported.


Sign in / Sign up

Export Citation Format

Share Document